NUVE FR 290 Скачать руководство пользователя страница 19

19 

 

6.1.4.

 

SMS 

 

In  order  to  use  SMS,  optional  GSM  module  is  mandatory  to  have.  Refer  to  Section 
10.1 for information regarding GSM module connection. 

 

 

“SMS” submenu is selected on the menu page by 
the  value  increase  (F1)  and  decrease  (F2)  keys. 
The page on the left appears when enter key (F4) 
is pushed. Submenus on SMS page is selected by 
using  increase  (F1)  and  decrease  (F2)  keys. 
Selected submenu can be adjusted by using enter 
key  (F4).  If  you  want  to  exit  the  page,  push  the 
backspace key (F3). 

 

Activation or deactivation of SMS function can be adjusted on “SMS” submenu. If you want 
to  activate  this  function,  choose  “on”  by  pushing  the  enter  key  (F4).  If  you  want  to 
deactivate SMS function, choose “Off” by pushing the enter key (F4).  

 

“Repeat time” is the frequency of sending SMS. The user is notified again by sending SMS if 
the failure still continues. Repeat time can be adjusted to 8 hours, 16 hours and 24 hours by 
pushing enter key (F4). 

 

 “SMS Numbers” is selected on the SMS page by 
using the  value increase (F1) and decrease (F2) 
keys.  The  page  on  the  left appears  when  enter 
key  (F4)  is  pushed.  The phone  numbers  can be 
entered  in  this  page  and  SMS  notifications  are 
delivered  to  these  phone  numbers  in  case  of 
any failure. 

 

SMS  can  be  sent  to  5  different  mobile  phones.  According  to  demand,  1

st

,  2

nd

  and  3

rd

 

numbers  can  be  users’  numbers  and  4

th

  and  5

th

  numbers  can  be  technical  service  staffs’ 

numbers. 

 

Enter country code before the phone numbers.  

 

A cursor flashes under a digit which means you can set this digit of the number. Each digit of 
phone  numbers  is  entered  one  by  one.  The  first  digit  of  the  phone  number  is  entered  by 
pushing value increase (F1) and decrease keys (F2) and tab key (F3) is pushed to enter the 
second digit. The second number is entered pushing value increase (F1) and decrease keys 
(F2) and tab key (F3) is pushed to enter the next digit. After all digits of the phone number 
are  entered  completely  by  this  way,  push  the  enter  key  (F4)  to  enter  the  next  phone 
number. 

 

Tab key (F3) is used for changeover from one digit of phone number to another. 

 

After all phone numbers from “Phone 1” to “Service 2” is entered as mentioned above, push 
the enter key (F4) and return to main page. 

Содержание FR 290

Страница 1: ...N VE SANAY MALZEMELER MALAT VE T CARET A FR 290 FR 490 FR 590 DEEP FREEZER USER S MANUAL 1984 Z14 K 25 275 Rev No 08 Rev Date 01 2016...

Страница 2: ...ate damaged instrument 4 do not operate the instrument with a damaged cable 5 do not move the instrument during operation In case of a problem contact your N ve agent for an authorized service or main...

Страница 3: ...nditions use of the product in non standard environmental conditions including but not limited to failure to meet requirements of ambient temperature lubrication humidity or magnetic field influences...

Страница 4: ...5 5 POSITIONING 10 5 6 GENERAL PRESENTATION 11 5 6 1 CHAMBER DIMENSIONS 12 5 7 CONTROL PANEL 12 5 8 PRIOR TO OPERATION 14 6 OPERATING PRINCIPLES 14 6 1 PROGRAMMING 14 6 1 1 OPERATING MODE 14 6 1 2 SET...

Страница 5: ...4 10 1 AlerText GSM MODULE 24 10 2 N veWARN REMOTE ALARM SYSTEM 25 10 2 1 MOUNTING REMOTE ALARM 25 10 3 CHART RECORDER 26 11 ELECTRICAL CIRCUIT DIAGRAM 27 11 1 FR 290 FR 490 AND FR 590 ELECTRICAL CIRC...

Страница 6: ...emperature conditions open door power failure temperature sensor failure and other faults associated with the microprocessor control system The alarm system is fed by an automatically re chargeable ba...

Страница 7: ...mpartments internal isolation doors 3 3 4 4 Control System N SmArt Programmable microprocessor system Temperature Indicator Colorful LCD Temperature Recorder Circular Battery operated 7 day chart with...

Страница 8: ...mm A 08 159 9 x 9 Divider for up to 13 6 mm tubes Divider height 65 mm A 08 196 Rack with two drawers FR 590 A 08 197 Rack with three drawers FR 590 A 08 198 Rack for 133 x 133 x 75 mm cryoboxes FR 59...

Страница 9: ...instructions This symbol refers to important circumstances Labels on the device Earthed Wall Sockets Remote alarm output Normally closed contact output FR 290 490 590 Fuses 2 x 13 A 5 INSTALLATION 5 1...

Страница 10: ...hat the supplied mains matches the required power ratings which are written on the name plate of the instrument located at the back of the instrument Always plug in the instrument to correctly grounde...

Страница 11: ...11 5 6 GENERAL PRESENTATION Figure 1 Figure 2 CONDENSER FILTER USB PORT 1 USB PORT 2 ETHERNET RS 232 CO2 BACK UP OUTPUT FUSES POWER CORD POWER LED NC CONTACT OUTPUT REMOTE ALARM OUTPUT POWER KEY...

Страница 12: ...mpartments different from FR 490 and FR 590 Figure 3 5 7 CONTROL PANEL Figure 4 The functions of F1 F2 F3 and F4 buttons depend on the meaning of the corresponding symbol appearing on the display The...

Страница 13: ...return the previous page or exit from the page by pushing the button corresponding to this symbol This symbol denotes the value increase key You can increase the value by pushing the button correspon...

Страница 14: ...tely in 3 hours if the chamber is not loaded This period depends on the ambient temperature 6 OPERATING PRINCIPLES 6 1 PROGRAMMING At most 70 of the surface area of the shelves should be loaded in ord...

Страница 15: ...2 SETTINGS Settings page appears when settings submenu is selected from the menu page by the value increase F1 and decrease F2 keys The required submenu is chosen by using the value increase and decr...

Страница 16: ...shing the value increase F1 and decrease F2 If the option of open is selected activation time of screen saver is adjusted on screen saver time in minutes If you want to exit this page without any chan...

Страница 17: ...ng the value increase and decrease keys Push the enter key F4 to access the table Temperature values corresponding to the selected date are shown on three pages Push the value increase F1 and decrease...

Страница 18: ...age there are three options Copy History Instant Record and Copy Failure History Copy History As USB stick is connected to the device all data in the internal memory is transferred to USB stick when C...

Страница 19: ...crease F1 and decrease F2 keys The page on the left appears when enter key F4 is pushed The phone numbers can be entered in this page and SMS notifications are delivered to these phone numbers in case...

Страница 20: ...the e mail addresses E Mails is selected on the e mail page by the value increase F1 and decrease F2 keys The page on the left appears when enter key F4 is pushed The e mail addresses can be typed in...

Страница 21: ...is used for changes from one character of address to another 6 1 6 SET TEMPERATURE When the setting key F2 is pushed in the operation mode password page appears This password is the user s password Th...

Страница 22: ...enser filter should be cleaned once in a month To access condenser filter pull out the front panel of the compressor compartment See Figure 5 Take out the filter and clean the filter with compressed a...

Страница 23: ...st be disposed off according to the regulations for the disposal of electronic components Batteries power packs and similar power source have to be dismounted from electric electronic parts and dispos...

Страница 24: ...se contact with an authorized N ve agent to seek technical help 9 2 FUSE REPLACEMENT The fuses shall always be replaced by authorized personnel 10 OPTIONS 10 1 AlerText GSM MODULE In case of error FR...

Страница 25: ...ppears in the error history If the GSM module is connected and cannot send messages SMS error code appears in the error history Modem and SMS errors do not appear when SMS submenu on the SMS page is s...

Страница 26: ...unit and take it out Put on the battery supplied with device to the hole at the back of the unit by paying attention to and poles Always use leak protected high quality batteries Put the battery unit...

Страница 27: ...27 11 ELECTRICAL CIRCUIT DIAGRAM 11 1 FR 290 FR 490 AND FR 590 ELECTRICAL CIRCUIT DIAGRAM...