Check the followings,

!

  the proposed site is suitable for users,

!

  the operator can follow up the unit even he deals with something else.

!

  the dry air sterilizer/oven does not occupy the utilisation space of others or  damage

them.

3.6.    Before Starting The Operation

Attention to the followings,

  Do not heat the samples which can liquefy or expand during the operation in sealed

containers.

  Determine of the boiling points of the samples and set the temperature accordingly.

  Make sure that the samples do not overflow from their containers when heated.

  Do not operate the dry air sterilizer/oven at the temperatures which do harm to the

samples or cause them to deform.

  Make sure that the ventilation hole is open to discharge the gas or vapour which

occurs during the operation.

  Make sure that the vapour occurred during the operation is not harmful to humans or

flammable or explosive.

IMPORTANT!

 The safety thermostat set value should always be higher than the working

temperature.

4.       OPERATING THE STERILIZER

4.

1

. Switching 

On

  Push On/Off switch.

  See that the microprocessor activates.

  Read section 4.2. to learn the functions of the microprocessor.

  Set the values ( see section 4.3) and start the operation.

Содержание FN 300

Страница 1: ...N VE SANAY MALZEMELER MALAT VE T CARET A FN 300 FN 400 FN 500 FN 400 P FN 500 P DRY AIR STERILIZERS OVENS USER S MANUAL N VE SANAY MALZEMELER MALAT VE T CARET A Z14 K 25 002 Rev No 01 Rev Date 09 200...

Страница 2: ...with the equipment 3 N ve does not accept any liability in the case where the goods are not used in accordance with their proper intent 4 The warranty may not be claimed for damages occurred during th...

Страница 3: ...itions 3 4 Mains Supply 3 5 Positioning 3 6 Before Starting the Operation 6 6 6 7 4 OPERATING THE DRY AIR STERILIZER 4 1 Switching On 4 2 Control Thermostat 4 3 Programming 4 4 End of the Program 5 PE...

Страница 4: ...ovens not only provides economical working conditions but also helps to achieve the excellent homogeneity The FN series dry air sterilizers ovens provide precise operation conditions with the PID mic...

Страница 5: ...thermostat Gas expansion thermostat 50 C 300 C Power consumption 500 W 800 W 750 W 1600 W 1500 W Power Supply 230 V 50 Hz Useful volume 22 liters 44 liters 42 liters 120 liters 110 liters Internal mat...

Страница 6: ...6 2 2 General View 1 Control panel 6 Shelf 2 Safety thermostat 7 Shelf carrier holder 3 On Off switch 8 Shelf carrier 4 Supply inlet and the fuses 9 Ventilation hole clips 5 Chamber gasket...

Страница 7: ...rature from 5 C to 40 C Humidity level 80 up to 22 C Maximum height 2000 m 3 4 Mains Supply The dry air sterilizer oven requires 230 V 10 50 Hz Please make sure that the supplied mains matches the req...

Страница 8: ...not overflow from their containers when heated Do not operate the dry air sterilizer oven at the temperatures which do harm to the samples or cause them to deform Make sure that the ventilation hole...

Страница 9: ...hen the program ends and if any failure occurs during the operation 4 Start Stop Key This is key which is pushed to start the program or to stop the running program 5 Temperature Set Key This key is p...

Страница 10: ...again to save the temperature value Push the time set key Set the time values by pushing the value increase decrease keys 01 min to 999 min or Hold Push the time set key again to save the value Push t...

Страница 11: ...rilizer does not operate check the following it is switched on it is plugged in properly or connected properly to the electric supply the plug is not defective the installation of the supply is not de...

Страница 12: ...12 7 ELECTRICAL CIRCUIT DIAGRAMS 7 1 FN 300...

Страница 13: ...13 7 2 FN 400...

Страница 14: ...14 7 3 FN 500...

Страница 15: ...15 7 4 FN 400 P...

Страница 16: ...16 7 5 FN 500 P...

Отзывы: