MCH60
Nuvair
Page 21
www.Nuvair.com
•
Place the system in a permanent location allowing a minimum spacing of 36” from adjacent walls.
Select a location where ambient room temperature is a minimum of +41°F (+5°C) to a maximum
+104°F (+40°C).
•
Make sure the installation space is well ventilated.
6.2 Electrical Connection
•
Please read all information supplied before connecting electricity to the compressor system.
•
You should hire a licensed electrician to install any electric compressors purchased from Nuvair.
•
The compressor is delivered with raw leads ready to be installed into a junction box.
•
In the event a plug is needed, Nuvair recommends that the licensed electrician doing the install
determines the plug necessary.
•
Make sure your electrician follows approved and compliant standards for your location.
7.0 Checks for the Start of Each Working Day
Inspect the exterior of the compressor (couplings, pipes, pneumatic components, etc.) and check for any oil
leaks. Replace parts where necessary or contact
Nuvair
.
7.1 Lubricating Oil Level Check
Check that the level of lubricating oil is within acceptable limits (i.e., between
minimum and maximum on the oil level viewer). Note that an excessive quantity of
oil can leave deposits on the valves while too low a level prevents proper
lubrication and could cause compressor seizure. If the oil level is not within the
minimum and maximum limits of the oil level viewer, top up or drain as described
in section 11.8, “Changing the Lubricating Oil and Filter”.
7.2 Check Refill Hoses
Inspect the refill hoses and make sure there are no cuts, holes, abrasions, leaks etc. If necessary, replace with
new hoses.
7.3 Storing Technical Documentation
The use and maintenance manual and its appendices must be stored carefully and must always be kept where
they can be accessed easily for immediate review.
This Operation Manual contains important safety information and should always be available to those
personnel operating this equipment. Read, understand, and retain all instructions before operating
this equipment to prevent injury or equipment damage.
8.0 Gauge Panel
The gauge panel matrix is described below, from left to right. Each compressor has five (5) individual gauges.
Compressor A gauges are on the top row; Compressor B gauges are on the bottom row.
Содержание MCH60
Страница 1: ...Operation Manual MCH60...
Страница 2: ...MCH60 Nuvair Page 1 www Nuvair com Notes...
Страница 3: ...MCH60 Nuvair Page 2 www Nuvair com Notes...
Страница 37: ...MCH60 Nuvair Page 36 www Nuvair com 19 0 Service Log Date Technician Name Service Performed...
Страница 41: ...MCH60 Nuvair Page 40 www Nuvair com Notes...
Страница 42: ...MCH60 Nuvair Page 41 www Nuvair com 22 0 PLC Wiring Schematics PLC wiring schematics on the following pages...
Страница 43: ...MCH60 Nuvair Page 42 www Nuvair com Notes...