www.NutriChefKitchen.com
Remark:
Improper combination would cause
leakage of beer.
3. Pull on pressure relieving ring for a couple of
seconds. If the keg was shaken in transit or
warmed, it may contain excessive pressure which
must be relieved before tapping. A hissing noise is
expected.
4. Slowly turn the regulator knob in clockwise
direction to 5 PSI, and stop for 2 seconds ad turn
off regulator. Wait for 2 mins, then pull on the
pressure relieving ring for a couple of seconds.
This is for adjusting pressure of keg beer.
5. Put a glass or pitcher under the faucet spout, with
the faucet knob pulled forward (ON), slowly turn
the regulator knob on in clockwise direction, until
beer starts to flow out.
In case there is CO2 leakage, please observe the
position of leakage and continue with the tightening
process, but never screw out if gas remains.
PART FOUR:
WARNING
1. Keep away from children under 18.
2. Never point cylinder towards someone’s face.
3. Do not heat over140°F as rupture may occur!
4. Discontinue using of this equipment if unsolvable
leakage or visible damage is found.
5. Capsule end become punctured when turned
into regulator base. Unscrewing before it’s empty
can result in loss of high pressure gas. Please
remember, never unscrew the CO2 capsule before
gas used up, liquid CO2 spray onto unprotected
skin may cause freezing burns.
6. Exterior of capsule may become frozen when in
use, this is normal. But don’t touch with bare
hands, your fingers could stick to the frozen
surface and cause frostbite.
7. Please ship via land or sea shipment, never bring
CO2 capsule when you travel by air.
Don’t continue adding pressure, suggest tapping
5-8 PSI (Max pressure 30 PSI), so please stop
turning the regulator knob when the pressure is
enough to tap beer out with perfect foam. Too
much pressure would cause over foam. When the
beer stopped or flow slower, try turning the
regulator knob on slowly, to get bigger pressure.
6. When you finish tapping, please turn regulator
knob to OFF position.
7. If there is no beer flowing out, then the CO2
capsule needs to be replaced, unless no beer is
remained (Normally, 16g capsule can tap 4-5 liters
of beer).
Caution:
Removing a punctured capsule from
regulator should be done slowly. Swish is expected
if pressure remains.
8. Turn the regulator knob off and install a new
capsule into the regulator by following above
steps.
TROUBLE SHOOTING GUIDE
1. Faucet Leakage
Solution:
Screw out and remove the faucet, then
install again, make sure the faucet can match the
connection of spear tightly.
2. Too much Foam
Solution:
Decrease the pressure properly.
3. Leakage of CO2
CO2 capsule should be installed properly and
tightly.
Questions? Issues?
We are here to help!
Phone:
(1) 718-535-1800
Email:
This product can expose you to a chemical or group of checmicals, which
may include
”Chromium”
which is known in the state of California to cause
cancer, birth defects, or other reproductive harm. For more info, go to
https://www.p65warnings.ca.gov/
.