background image

www.NutriChefKitchen.com

Remark:

 Improper combination would cause 

leakage of beer.

3. Pull on pressure relieving ring for a couple of  
    seconds. If the keg was shaken in transit or    
    warmed, it may contain excessive pressure which  
    must be relieved before tapping. A hissing noise is  
    expected.

4. Slowly turn the regulator knob in clockwise    
    direction to 5 PSI, and stop for 2 seconds ad turn  
    off regulator. Wait for 2 mins, then pull on the  
    pressure relieving ring for a couple of seconds.  
    This is for adjusting pressure of keg beer.
5. Put a glass or pitcher under the faucet spout, with  
    the faucet knob pulled forward (ON), slowly turn  
    the regulator knob on in clockwise direction, until  
    beer starts to flow out.

In case there is CO2 leakage, please observe the 
position of leakage and continue with the tightening 
process, but never screw out if gas remains.  

PART FOUR: 

WARNING

1. Keep away from children under 18.
2. Never point cylinder towards someone’s face.
3. Do not heat over140°F as rupture may occur!
4. Discontinue using of this equipment if unsolvable  
    leakage or visible damage is found.
5. Capsule end become punctured when turned  
    into regulator base. Unscrewing before it’s empty  
    can result in loss of high pressure gas. Please   
    remember, never unscrew  the CO2 capsule before  
    gas used up, liquid CO2 spray onto unprotected  
    skin may cause freezing burns.
6. Exterior of capsule may become frozen when in  
    use, this is normal. But don’t touch with bare   
    hands, your fingers could stick to the frozen    
    surface and cause frostbite.
7. Please ship via land or sea shipment, never bring  
    CO2 capsule when you travel by air.

    Don’t continue adding pressure, suggest tapping      
    5-8 PSI (Max pressure 30 PSI), so please stop    
    turning the regulator knob when the pressure is      
    enough to tap beer out with perfect foam. Too      
    much pressure would cause over foam. When the      
    beer stopped or flow slower,  try turning the   
    regulator knob on slowly, to get bigger pressure.
6. When you finish tapping, please turn regulator      
    knob to OFF position.
7. If there is no beer flowing out, then the CO2    
    capsule needs to be replaced, unless no beer is  
    remained (Normally, 16g capsule can tap 4-5 liters  
    of beer).

  

Caution:

 Removing a punctured capsule from 

regulator should be done slowly. Swish is expected 
if pressure remains.

8. Turn the regulator knob off and install a new   
    capsule into the regulator by following above      
    steps.

TROUBLE SHOOTING GUIDE

1. Faucet Leakage

     Solution:

 Screw out and remove the faucet, then  

     install again, make sure the faucet can match the  
     connection of spear tightly.

2. Too much Foam

    Solution:

 Decrease the pressure properly.

3. Leakage of  CO2

     CO2 capsule should be installed properly and  
     tightly.

Questions? Issues?

We are here to help!
Phone: 

(1) 718-535-1800

Email: 

[email protected]

This product can expose you to a chemical or group of checmicals, which 

may include 

”Chromium”

 

which is known in the state of California to cause 

cancer, birth defects, or other reproductive harm. For more info, go to 

https://www.p65warnings.ca.gov/

.

Отзывы: