ZN110L Installation Guide

Page 12

WARNING

 

Before servicing or cleaning unit, 

switch power off at service panel and lock the service 
disconnecting means to prevent power from being 
switched on accidentally. When the service disconnecting 
means cannot be locked, securely fasten a prominent 
warning device, such as a tag, to the service panel. 

Operation

To Turn Fan ON

Turn the master switch ON.
It is normal for this ventilation fan to take approximately 5 
seconds to start running after it is turned on.
•  Fan will run at the certified airflow rate if the mode 

select switch is ON.

•  Fan will run at the user-adjustable airflow rate if the 

mode select switch is OFF.

To Use Fan Time Delay Airflow Rate Change

1.  Turn the master switch ON.
2.  Turn the mode select switch ON - fan will run at the 

certified airflow rate.

3.  When the mode select switch is turned OFF, fan will 

continue to run at the certified airflow rate until the 

user-adjustable time delay has elapsed, and then will 

automatically change to the user-adjustable airflow rate.

To Set the User-Adjustable Airflow Rate*

Using a small, flat-blade screwdriver, carefully rotate the 

CFM adjustment until the arrow points to the desired 

airflow rate.
To Set the User-Adjustable Time Delay*

Using a small, flat-blade screwdriver, carefully rotate the 

TIME adjustment until the arrow points to the desired time 

delay, shown in minutes.

*  The user-adjustable controls are located in one corner 

of the Fan Housing, behind the Grille.

To Turn Fan OFF

Turn the master switch OFF. 
To Operate Lights

The light and night light can be operated independently, 

using separate on/off switches.

Cleaning and Maintenance

To Clean

For quiet and efficient operation, long life and attractive 

appearance, remove Grille and vacuum interior of unit 

with a dusting brush attachment.  
The Motor is permanently lubricated and never needs 

oiling. If the motor bearings are making excessive or 

unusual noises, replace the Control Assembly and Motor.
To Change Bulbs

Refer to Retrofit Installation 

Step 14

 (page 11).

1.  Carefully insert a small 

flathead screwdriver 

between the Grille and Lens, 

then twist to remove Lens.

2.  Purchase two (2) 18W (max.) 

type GU24 fluorescent 

lamps with Maximum Overall 

Length (MOL) of 3.9" (100 

mm). Purchase a 4W (max.) 

C7-type incandescent night light bulb.

3.  Insert bulbs into their sockets. Replace Lens.

Troubleshooting

Symptom: The fan does not run. 

•  Check for an open fuse or circuit breaker in the 

building’s service panel. 

•  Check that the two (2) plug-in connections for the Motor 

and the Control are seated firmly in place. 

•  Check that the Blower Wheel spins freely.
Symptom: The fan runs erratically. 

•  Check that the Blower Wheel is firmly attached to the 

Motor shaft and both spin freely. 

Symptom: The fan seems noisy. 

•  Check that the back draft damper in the fan’s Duct 

Connector pivots freely. Screws used to attach the duct 

to the Duct Connector may be preventing the damper 

from opening. 

•  Check that the back draft damper in the wall or roof cap 

pivots freely. These dampers are sometimes mistakenly 

painted shut or obstructed by bird and insect debris.

Symptom: The fan does not properly ventilate the room.

•  For spot ventilation, turn both the master switch and the 

mode select switch ON to enable the fan to run at the 

certified airflow rate. 

•  For spot ventilation followed by continuous ventilation, 

increase the “TIME” setting of the user-adjustable time 

delay. 

•  For continuous ventilation, increase the “CFM” setting of 

the user-adjustable airflow rate. 

          

ZN80L User-adjustable controls

 

          

ZN110L User-adjustable controls

 

M.O.L. 

3.9" 

(100 mm)

CAUTION

IN ORDER TO PREVENT MOTOR/CONTROL DAMAGE:
DO NOT remove motor plug to stop spinning motor.
Power must be disconnected (see WARNING at top left of 

this page) before motor plug is removed or inserted into 

control assembly.

 

Содержание ZN110L

Страница 1: ...th homeowner Register your product online at www nutone com register Easy installation in both new construction and retrofit Table of Contents Warnings and Cautions 2 Typical Installation 2 New Construction Installation 3 Retrofit Installation 7 Operation 12 Cleaning and Maintenance 12 Troubleshooting 12 Service Parts 13 Warranty 13 2011 Broan NuTone LLC ...

Страница 2: ... or ceiling do not damage electrical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 Use only ON OFF switch mechanical timer or relay switched control 8 Acceptable for use over a tub or shower when connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit 9 This unit must be grounded Typical Installation CAUTION 1 For general ventilating ...

Страница 3: ...wdriver with a Phillips bit Phillips screwdriver Flathead screwdriver Pliers Wire insulation stripper Wire cutter Materials needed 6 round metal ducting recommended for best performance Use of other ducting is acceptable but may impact performance Roof cap or wall cap built in damper recommended Tape to seal duct connections Electrical wiring and supplies per local code requirements 4W max C7 type...

Страница 4: ...nd Ducting Position Housing between joists and crimp channel on both sides of Mounting Frame to lock Housing in place Do not crimp Housing Screws from Parts Bag Top and bottom flanges go outside Housing Insert tab into slot inside Housing Screw from Parts Bag 6 to 4 Reducer provided in select models Tape Tape Tape 6 Ducting 4 Ducting snap ...

Страница 5: ... Parts Bag Attach cable clamps to Knockout Plate Knockout Plate mounts to outside of Housing and may be oriented as desired Connect wires Fan Light LINE IN GRD GRD WHT WHT WHT WHT WHT WHT BLK BLK BLK BLU BLK RED RED RED RED BLK MASTER ON OFF SWITCH FAN MODE SELECT SWITCH FAN LIGHT LIGHT NIGHT LIGHT NIGHT LIGHT UNIT SWITCH BOX KNOCKOUT PLATE FAN RECEPTACLE LIGHT RECEPTACLE LIGHT RECEPTACLE WIRES FA...

Страница 6: ...s Cleaning and Maintenance and Troubleshooting Mask protects unit during construction Remove before installing Grille Night Light purchase separately Install ceiling material Cut out around Housing CAUTION If the blower was unplugged power must be disconnected see page 2 WARNING item 2 before inserting motor plug into control assembly IN ORDER TO PREVENT MOTOR CONTROL DAMAGE ...

Страница 7: ... damaged If any damage is found DO NOT CONTINUE INSTALLATION of this product Contact a qualified person s for repair Remove Instruction Sheet Remove CFL Bulbs from protective packaging Punch out Mask from packaging See Step 12 1 Remove Packaging 2 Switch Off Power 4 Examine Wiring 3 Enlarge Ceiling Opening and Remove Existing Fan Ruler Pencil Drywall saw Claw hammer or pry bar Utility knife Materi...

Страница 8: ... 4 5 1 1 2 3 3 Retrofit Installation 5 Remove Blower Assembly 6 Remove Wiring Panel 7 Insert Mounting Frame Both sides Set aside Blower Assembly Set aside Wiring Panel Set aside screw Bend up four tabs Remove screws from Mounting Frame and set aside ...

Страница 9: ... in Step 7 Pull existing wiring into Housing as it is inserted into Mounting Frame Pull existing ductwork into Housing Insert tab into slot inside Housing 10 Attach Ducting and Duct Connector 8 Secure Mounting Frame 9 Snap in Housing snap 6 to 4 Reducer provided in select models Tape Tape Tape 6 Ducting 4 Ducting ...

Страница 10: ...HT LIGHT UNIT SWITCH BOX KNOCKOUT PLATE FAN RECEPTACLE LIGHT RECEPTACLE LIGHT RECEPTACLE WIRES FAN RECEPTACLE WIRES DUAL CONTROLS purchase separately 120 VAC LINE IN MODE SELECT MASTER ON OFF SWITCH FAN SWITCH BOX LIGHT NIGHT LIGHT BLACK WHITE BLUE RED GROUND green or bare Use proper UL approved connectors to secure wiring to the Knockout Plate provided in Parts Bag Connect wires as shown in wirin...

Страница 11: ...iling repairs are needed place Mask in Housing after Blower Assembly is secured See New Construction Installation Step 6 Remove Mask before installing Grille Screws from Parts Bag Night Light purchase separately CAUTION Power must be disconnected see page 2 WARNING item 2 before inserting motor plug into control assembly IN ORDER TO PREVENT MOTOR CONTROL DAMAGE ...

Страница 12: ...sh attachment The Motor is permanently lubricated and never needs oiling If the motor bearings are making excessive or unusual noises replace the Control Assembly and Motor To Change Bulbs Refer to Retrofit Installation Step 14 page 11 1 Carefully insert a small flathead screwdriver between the Grille and Lens then twist to remove Lens 2 Purchase two 2 18W max type GU24 fluorescent lamps with Maxi...

Страница 13: ...ce storage or repair other than repair by NuTone d damage caused by faulty installation or installation or use contrary to recommendations or instructions e any Fan that has been moved from its original point of installation f damage caused by environmental or natural elements g damage in transit h natural wear of finish i Fans in commercial or nonresidential use or j damage caused by fire flood o...

Страница 14: ...ZN80L n ZN110L Installation Guide Page 14 99045256A ...

Страница 15: ... de casa Registre su producto en línea en el sitio www nutone com register Instalación sencilla tanto en construcciones nuevas como en modernizaciones Tabla de contenido Advertencias y precauciones 2 Instalación típica 2 Instalación en una construcción nueva 3 Instalación en modernizaciones 7 Funcionamiento 12 Limpieza y mantenimiento 12 Identificación y solución de fallas 13 Repuestos 13 Garantía...

Страница 16: ...6 Los ventiladores conectados a conductos siempre deben tener ventilación hacia el exterior 7 Use solamente un interruptor de ENCENDIDO APAGADO un temporizador mecánico o un control de relé interruptor 8 La unidad sólo debe conectarse a un circuito de alimentación protegido por un interruptor de circuito para fallas con conexión a tierra ICFT 9 Esta unidad debe estar conectada a tierra Instalación...

Страница 17: ...lador Phillips Destornillador de cabeza plana Pinza Pelacable para la aislación de los cables Pinza cortacable Materiales necesarios Conducto circular de metal de 6 pulg recomendado para un mejor rendimiento Se acepta el uso de otro tipo de conducto pero esto puede afectar el rendimiento Capuchón para tejado o de pared se recomienda utilizar uno con regulador de tiro incorporado Cinta para sellar ...

Страница 18: ...nal a ambos lados del bastidor de montaje para que el compartimiento quede asegurado en su lugar No ajuste el compartimiento Pernos de la bolsa de piezas Las bridas superior e inferior deben ir por fuera del compartimiento Introduzca la pestaña en la ranura en el interior del compartimiento Perno de la bolsa de piezas Algunos modelos cuentan con un adaptador de 6 a 4 pulg Cinta Cinta Cinta Conduct...

Страница 19: ...AGADO ON OFF TABLERO ELÉCTRICO LUZ LUZ NOCTURNA NEGRO BLANCO CONEXIÓN A TIERRA verde o sin protección ROJO AZUL Instalación en una construcción nueva 5 Conecte los cables e instale la placa metálica Extienda un cableado eléctrico de 120 VCA hasta el sitio de la instalación Utilice conectores aprobados por UL para asegurar el cableado hasta la placa metálica que se incluye en la bolsa de piezas Con...

Страница 20: ...miento e Identificación y solución de fallas La máscara protege la unidad durante la construcción Retírela antes de instalar la rejilla Luz nocturna comprar por separado Instale el material del techo Corte alrededor del compartimiento PRECAUCIÓN Si el motor estaba desconectado se debe desconectar la electricidad vea la página 2 ADVERTENCIA punto 2 antes de insertar el enchufe del motor en el conju...

Страница 21: ...este producto Comuníquese con la s persona s calificada s para realizar la reparación Retire la hoja de instrucciones Retire las lámparas fluorescentes compactas de su envase protector Retire la máscara del envase Consulte el Paso 12 1 Retire el envase 2 Desconecte el suministro de energía 4 Verifique el cableado 3 Aumente la abertura del techo y retire el ventilador existente Regla Lápiz Sierra p...

Страница 22: ...nizaciones 5 Retire el conjunto del ventilador 6 Retire el panel con los cables 7 Introduzca el bastidor de montaje Ambos lados Aparte el conjunto del ventilador Aparte el panel con los cables Aparte el perno Despliegue las cuatro pestañas Retire los pernos del bastidor de montaje y apártelos ...

Страница 23: ... en el bastidor de montaje Introduzca el conducto existente en el compartimiento Introduzca la pestaña en la ranura que se encuentra en el interior del compartimiento 10 Fije el conector del conducto y los conductos 8 Asegure el bastidor de montaje 9 Coloque el compartimiento a presión Cinta Cinta Cinta Presione hasta que trabe Algunos modelos cuentan con un adaptador de 6 a 4 pulg Conducto de 6 p...

Страница 24: ... ENCENDIDO APAGADO ON OFF TABLERO ELÉCTRICO LUZ LUZ NOCTURNA NEGRO BLANCO CONEXIÓN A TIERRA verde o sin protección ROJO AZUL Instalación en modernizaciones 11 Instale la placa metálica conecte los cables e instale el panel de cableado Perno de la bolsa de piezas Fije las abrazaderas de los cables a la placa metálica La placa metálica debe montarse en el interior del compartimiento y se la puede ub...

Страница 25: ...techo coloque la máscara en el compartimiento después de asegurar el conjunto del ventilador Consulte el Paso 6 de Instalación en una construcción nueva Retire la máscara antes de instalar la rejilla Pernos de la bolsa de piezas Luz nocturna comprar por separado PRECAUCIÓN Debe desconectar la electricidad vea la página 2 ADVERTENCIA punto 2 antes de insertar el enchufe del motor en el conjunto de ...

Страница 26: ...ión del retardo del tiempo ajustable por el usuario Utilizando un destornillador pequeño de punta plana haga girar con cuidado el ajuste del tiempo TIME hasta que la flecha indique el retardo de tiempo deseado que se mostrará en minutos Los controles ajustables por el usuario están ubicados en una de las esquinas del compartimiento del ventilador detrás de la rejilla Desconexión del ventilador Des...

Страница 27: ...ctos Síntoma El ventilador no ventila el ambiente en forma correcta Para ventilar el sitio encienda el interruptor principal y el interruptor selector de modo para permitir que el ventilador funcione al índice de caudal de aire certificado Para ventilar el sitio después de la ventilación continua aumente la configuración del tiempo del retardo del tiempo ajustable por el usuario Para la ventilació...

Страница 28: ...ro caso fortuito Esta garantía cubre sólo a los Ventiladores que se venden en los Estados Unidos o a través de representantes de los Estados Unidos autorizados por NuTone EXCLUSIÓN DE DAÑOS LA OBLIGACIÓN DE NUTONE DE PROPORCIONAR REPUESTOS O LA REPARACIÓN O EL REEMPLAZO A DISCRECIÓN DE NUTONE SERÁ LA ÚNICA Y EXCLUSIVA COMPENSACIÓN BAJO EL AMPARO DE ESTA GARANTÍA LIMITADA Y LA ÚNICA Y EXCLUSIVA OBL...

Отзывы: