background image

ZN110H  Installation Guide

Page 14

99045851A

Warranty

NuTone Ventilation Fans Limited Warranty

WARRANTY PERIOD: NuTone warrants to the original consumer purchaser of 

its NuTone Ventilation Fans (the “Fan”) that your Fan will be materially free from 

defects in materials or workmanship for a period of three (3) years from the date 

of original purchase. This warranty does not cover accessories, such as speed 

controls, that may be purchased separately and installed with the Fan.

The limited warranty period for replacement parts, and for Fans repaired or 

replaced under this limited warranty, shall continue for the remainder of the 

original warranty period.

NO OTHER WARRANTIES: THE FOREGOING WARRANTIES ARE 

EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR 

IMPLIED. NUTONE DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS 

WARRANTIES, AND DISCLAIMS AND EXCLUDES ALL WARRANTIES 

IMPLIED BY LAW, INCLUDING WITHOUT LIMITATION THOSE OF 

MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. TO 

THE EXTENT THAT APPLICABLE LAW PROHIBITS THE EXCLUSION OF 

IMPLIED WARRANTIES, THE DURATION OF ANY APPLICABLE IMPLIED 

WARRANTY IS LIMITED TO THE PERIOD SPECIFIED FOR THE EXPRESS 

WARRANTY. Some states do not allow limitations on how long an implied 

warranty lasts, so the above limitation may not apply to you. Any oral or written 

description of the Fan is for the sole purpose of identifying it and shall not be 

construed as an express warranty.

REMEDY: During the applicable limited warranty period, NuTone will, at its 

option, provide replacement parts for, or repair or replace, without charge, 

any Fan or part thereof, to the extent NuTone finds it to be covered by and in 

breach of this limited warranty. NuTone will ship the repaired or replaced Fan 

or replacement parts to you at no charge. You are responsible for all costs for 

removal, reinstallation and shipping, insurance or other freight charges incurred 

in the shipment of the Fan or part to NuTone. This warranty does not cover (a) 

normal maintenance and service, (b) normal wear and tear, (c) any Fans or 

parts which have been subject to misuse, abuse, abnormal usage, negligence, 

accident, improper or insufficient maintenance, storage or repair (other than 

repair by NuTone), (d) damage caused by faulty installation, or installation or 

use contrary to recommendations or instructions, (e) any Fan that has been 

moved from its original point of installation, (f) damage caused by environmental 

or natural elements, (g) damage in transit, (h) natural wear of finish, (i) Fans in 

commercial or nonresidential use, or (j) damage caused by fire, flood or other 

act of God. This warranty covers only Fans sold in the United States or through 

U.S. distributors authorized by NuTone. 

EXCLUSION OF DAMAGES: NUTONE’S OBLIGATION TO PROVIDE 

REPLACEMENT PARTS, OR REPAIR OR REPLACE, AT NUTONE’S 

OPTION, SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER 

THIS LIMITED WARRANTY AND NUTONE’S SOLE AND EXCLUSIVE 

OBLIGATION. NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, 

INDIRECT, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT 

OF OR IN CONNECTION WITH THE FAN, ITS USE OR PERFORMANCE. 

Incidental damages include but are not limited to such damages as loss of time 

and loss of use. Consequential damages include but are not limited to the cost 

of repairing or replacing other property which was damaged if the Fan does not 

work properly. 

Some states do not allow the exclusion or limitation of incidental or 

consequential damages, so the above limitation or exclusion may not apply to 

you. This warranty gives you specific legal rights, and you may also have other 

rights, which vary from state to state. 

This warranty supersedes all prior warranties and is not transferable from the 

original consumer purchaser. 

NUTONE SHALL NOT BE LIABLE TO YOU, OR TO ANYONE CLAIMING 

UNDER YOU, FOR ANY OTHER OBLIGATIONS OR LIABILITIES, 

INCLUDING, BUT NOT LIMITED TO, OBLIGATIONS OR LIABILITIES 

ARISING OUT OF BREACH OF CONTRACT OR WARRANTY, NEGLIGENCE 

OR OTHER TORT OR ANY THEORY OF STRICT LIABILITY, WITH RESPECT 

TO THE FAN OR NUTONE’S ACTS OR OMISSIONS OR OTHERWISE. 

This warranty covers only replacement or repair of defective Fans or parts 

thereof at NuTone’s main facility and does not include the cost of field service 

travel and living expenses.

Any assistance NuTone provides to or procures for you outside the terms, 

limitations or exclusions of this limited warranty will not constitute a waiver of 

such terms, limitations or exclusions, nor will such assistance extend or revive 

the warranty.

NuTone will not reimburse you for any expenses incurred by you in repairing or 

replacing any defective Fan, except for those incurred with NuTone’s prior written 

permission.

HOW TO OBTAIN WARRANTY SERVICE: To qualify for warranty service, you 

must (a) notify NuTone at the address or telephone number stated below within 

seven (7) days of discovering the covered defect, (b) give the model number 

and part identification and (c) describe the nature of any defect in the Fan or 

part. At the time of requesting warranty service, you must present evidence of 

the original purchase date. 

Broan, 926 West State Street, Hartford, WI  53027  

(1-888-336-6151)

www.nutone.com

If you must send the Fan or part to NuTone, as instructed by NuTone, you must 

properly pack the Fan or part—NuTone is not responsible for damage in transit.

Содержание ZN110H

Страница 1: ...homeowner Register your product online at www nutone com register Easy installation in both new construction and retrofit Table of Contents Warnings and Cautions 2 Typical Installation 2 New Construct...

Страница 2: ...se over a tub or shower when connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit 9 This unit must be grounded Typical Installation CAUTION 1 For general ventilating use only...

Страница 3: ...eeded 6 round metal ducting recommended for best performance Use of other ducting is acceptable but may impact performance Roof cap or wall cap built in damper recommended Tape to seal duct connection...

Страница 4: ...4 Attach Duct Connector and Ducting Position Housing between joists and crimp channel on both sides of Mounting Frame to lock Housing in place Do not crimp Housing Screws from Parts Bag Top and botto...

Страница 5: ...CH BOX BLACK WHITE RED BLUE purchase separately SENSOR CONTROL SWITCH GROUND green or bare ORANGE BROWN See OPERATION section on page 12 for details MASTER switch turns fan system on and shuts it off...

Страница 6: ...g and Maintenance and Troubleshooting Mask protects unit during construction Remove before installing Grille Install ceiling material Cut out around Housing Plug in Sensor CAUTION If the blower was un...

Страница 7: ...ing wiring to make sure it is not damaged If any damage is found DO NOT CONTINUE INSTALLATION of this product Contact a qualified person s for repair Remove Instruction Sheet Punch out Mask from packa...

Страница 8: ...1 1 2 3 3 Retrofit Installation 5 Remove Blower Assembly 6 Remove Wiring Panel 7 Insert Mounting Frame Both sides Set aside Blower Assembly Set aside Wiring Panel Set aside screw Bend up four tabs Rem...

Страница 9: ...arts Bag Screws set aside in Step 7 Pull existing wiring into Housing as it is inserted into Mounting Frame Pull existing ductwork into Housing Insert tab into slot inside Housing 10 Attach Ducting an...

Страница 10: ...G MASTER WALL SWITCH GRD WHT BLK GRD WHT BLK BRN 120 VAC LINE IN 14 2 RED MASTER WALL SWITCH KNOCKOUT PLATE RECEPTACLES 120 VAC LINE IN SWITCH BOX BLACK WHITE purchase separately GROUND green or bare...

Страница 11: ...epairs are needed place Mask in Housing after Blower Assembly is secured See New Construction Installation Step 6 Remove Mask before installing Grille Screws from Parts Bag Plug in Sensor CAUTION Powe...

Страница 12: ...have a separate sensor control wall switch where it is combined with master wall switch then turn master wall switch on and off using following instructions 3 Wait at least one second 4 Turn switch of...

Страница 13: ...its Control are seated firmly in place Check that Blower Wheel spins freely Symptom Humidity mode does not operate fan at certified air flow rate Check two 2 plug in connections for Sensor and its Co...

Страница 14: ...ge caused by fire flood or other act of God This warranty covers only Fans sold in the United States or through U S distributors authorized by NuTone EXCLUSION OF DAMAGES NUTONE S OBLIGATION TO PROVID...

Страница 15: ...la casa Registre su producto en l nea en www nutone com register F cil instalaci n en construcciones nuevas y en aplicaciones de conversi n ndice Advertencias y precauciones 2 Instalaci n t pica 2 Ins...

Страница 16: ...bre una tina o ducha siempre que se conecte a un GFCI interruptor accionado por p rdida de conexi n a tierra en un circuito de derivaci n protegido 9 Esta unidad debe estar conectada a tierra Instalac...

Страница 17: ...cm para obtener un desempe o ptimo Aunque el uso de otros sistemas de conductos es aceptable puede afectar al desempe o Tapa de techo o tapa de pared se recomienda que tenga regulador de tiro integrad...

Страница 18: ...que la cubierta entre las vigas y doble el canal a ambos lados del marco de montaje para fijar la cubierta en su lugar No doble la cubierta Tornillos de la bolsa de piezas Las bridas superior e inferi...

Страница 19: ...VCA CAJA DEL INTERRUPTOR NEGRO BLANCO ROJO AZUL Se compra por separado INTERRUPTOR DE CONTROL DEL SENSOR TIERRA Verde o sin aislamiento ANARANJADO MARR N Vea los detalles de la secci n FUNCIONAMIENTO...

Страница 20: ...mpieza mantenimiento y resoluci n de problemas La cubierta protege la unidad durante la construcci n Ret rela antes de instalar la rejilla Instale el material del cielo raso Recorte alrededor de la cu...

Страница 21: ...Sierra para panel de yeso Martillo de u as o pata de cabra Navaja utilitaria Materiales necesarios Cinta para sellar las conexiones de los conductos Los conductos r gidos existentes requerir n la adic...

Страница 22: ...el conjunto del ventilador 6 Retire el panel de cableado 7 Inserte el marco de montaje Ambos lados Ponga a un lado el conjunto del ventilador Ponga a un lado el panel de cableado Ponga a un lado el to...

Страница 23: ...ente hacia el interior de la cubierta a medida que lo inserta en el marco de montaje Tire de los conductos existentes hacia el interior de la cubierta 10 Acople el conector de conductos y los conducto...

Страница 24: ...NEGRO TIERRA BLANCO NEGRO CAF 120 VCA L NEA DE ENTRADA 14 2 ROJO INTERRUPTOR DE PARED MAESTRO INTERRUPTOR DE PARED MAESTRO PLACA DE AGUJERO CIEGO RECEPT CULOS L NEA DE ENTRADA DE 120 VCA CAJA DEL INTE...

Страница 25: ...ctor en la cubierta despu s de haber fijado el conjunto del ventilador Consulte el paso 6 sobre la instalaci n en una construcci n nueva Retire la cubierta protectora antes de instalar la rejilla Torn...

Страница 26: ...talaciones no dispongan de un interruptor de pared independiente para el sensor control en los casos en que este interruptor est combinado con un interruptor de pared maestro encienda y apague el inte...

Страница 27: ...e funcionar el ventilador al ndice nominal de flujo de aire Aseg rese de que los dos 2 conectores de enchufe del sensor y de su control est n bien afianzados en su lugar S ntoma El ventilador funciona...

Страница 28: ...en los Estados Unidos o a trav s de representantes de los Estados Unidos autorizados por NuTone EXCLUSI N DE DA OS LA OBLIGACI N DE NUTONE DE PROPORCIONAR REPUESTOS O LA REPARACI N O EL REEMPLAZO A D...

Отзывы: