SERVICE PARTS

99044373C

INSTALL GRILLE

6.  Attach grille 

to housing.

Squeeze grille 
springs and insert 
them into slots on 
each side of hous-
ing.

7.  Push grille 

against 
ceiling.

5.  Finish ceiling.

Install ceiling material. Cut out around housing.

4.  Connect electrical wiring.

Run 120 VAC house wiring to installation location. Use 

proper UL approved connector to secure house wiring to 

wiring plate. Connect wires as shown in wiring diagrams.

CONNECT WIRING

Order service parts by “Part No.” - not by “Key No.”

SERVICE NOTE To remove Blower Assembly: Unplug motor. 
Remove thumbscrew (11) from motor plate flange. Find the 
single

TAB on the motor plate (located next to the receptacle). 

Push up near motor plate tab while pushing out on side of 
housing. Or insert a straight-blade screwdriver into slot in 
housing (next to tab) and twist screwdriver.

Replacement parts can 

be ordered on our web-

site. Please visit us at 

www.nutone.com

Key No.  Part No. 

Description

97016466 Housing

97016449  Duct Connector-4”

98010102 

Wiring Plate

99170245  Screw, #8-18 X .375

5 97018010 

Wire Panel/Harness Assembly

6 97017783 

Blower Assembly (QTREN080)

97017854  Blower Assembly (QTREN110)

7 97017623 

Grille Assembly
  (includes key no. 8)

99140199 

Grille Spring (2 req’d)

97018014 

Spacer (2 supplied)

10 

QTNHB1 

Hanger Bar Kit

11 

99420665  Thumbscrew, #8-18 x .375

Содержание ULTRA SILENT QTRN Series

Страница 1: ...replace the blower assembly includes motor and impeller OPERATION Use an on off switch or speed control to operate this ventilator See Connect Wiring for details Use of speed controls other than the N...

Страница 2: ...line voltage and appropriate power cable Housing mount ed anywhere between I joists using hanger bars Housing mount ed to joists Housing mount ed anywhere between joists using hanger bars Housing moun...

Страница 3: ...b Mount housing anywhere between trusses joists or I joists using hanger bars Sliding hanger bars are provided to allow for accurate posi tioning of housing anywhere between framing They can be used o...

Страница 4: ...motor Remove thumbscrew 11 from motor plate flange Find the single TAB on the motor plate located next to the receptacle Push up near motor plate tab while pushing out on side of housing Or insert a...

Страница 5: ...con el accesorio del cepillo para sacudir polvo El motor est permanentemente lubricado y nunca necesitar aceite Si los cojinetes del motor est n haciendo ruido excesivo o inusual reemplace el conjunto...

Страница 6: ...requiera el tramo de conducto m s corto posible y un m nimo n mero de codos Instale una tapa de techo o de pared que tenga un regulador de tiro incorporado a fin de reducir los contratiros Alimente l...

Страница 7: ...de montaje del canal marcados como STD para montar la cubierta al ras con la parte inferior de la tablarroca Utilice el otro juego de orificios sin marca para montar la cubierta al ras con la parte su...

Страница 8: ...no el n mero de la clave 99044373C NOTA DE SERVICIO Para desmontar el conjunto del ven tilador Desenchufe el motor Saque el tornillo de mariposa 11 de la brida de la placa del motor Localice la LENG...

Отзывы: