WIRING

Refer Figure 2.

1. Run 120v AC house power wiring (with ground) through switch box to

junction box in ventilator housing.

2. Remove ventilator junction box cover.
3. Referencing figure 2 connect the house power wire (black) to the

connector black wire. Connect the house neutral wire (white) to  both
the connector and motor plug wires (white). Connect the  ground wire
to the green ground screw. Connect the blue connector wire to the
black motor plug wire.

4. Replace junction box cover.
5. Connect house power wire to standard toggle switch.

NOTE: BE SURE VENTILATOR AND SWITCH ARE PROPERLY

GROUNDED. ALL WIRING MUST COMPLY WITH LOCAL
ELECTRICAL CODES.

SENSOR UNIT INSTALLATION

Refer Figure 3.

1. Align sensor cover tabs with slots in junction box cover. Firmly

press sensor cover to engage connector.

2. Secure sensor unit using mounting screw through hole in unit

cover flange.

POWER/BLOWER UNIT INSTALLATION

1. Plug motor into socket in housing's junction box.

2. Position power unit mounting plate over mounting screws in

housing.

3. Slide unit forward until the gasket fits firmly against discharge

opening in housing and mounting screws are seated in narrow
end of keyhole slots.

4.

Refer to Figure 4.

Securely tighten screws.

GRILLE INSTALLATION

1.

Refer to Figure 4.

Snap grille mounting springs' center loop into

notched bosses on the back of grille.

2. Place grille mounting springs into slots in power unit mounting

plate.

3. Press grille firmly into place against the ceiling.

FIGURE 3

INSTALLATION IN EXISTING CONSTRUCTION

Installing the ventilator in an existing house requires an accessible

area (attic crawl space) above the planned installation location.

Review “INSTALLATION IN A NEW CONSTRUCTION” and

follow all instructions which apply to your installation.

Location –

locate ventilator parallel to a ceiling joist.

Wiring and Ducting –

plan ducting and wiring before proceeding

with installation.

Refer to Figure 2 for wiring and Figure 1 for ducting.

CAUTION: Check area above planned installation to be sure that:

1. Ducting can be installed.

2. Wiring can be run to the planned location.

3. No wiring or other obstructions might interfere with

installation.

INSTALLATION FROM ACCESSIBLE

AREA ABOVE

1. From below, drill a small hole in ceiling at the planned location.

Stick clothes hanger through hole to help locate it.

2. Locate hole in attic or crawl space.

3. In attic or crawl space, mark ceiling for cutout by using the 

housing as a template. The long side of cutout must be parallel 
to ceiling joist.

4. Make cutout along marked line.

NOTE: If ceiling is plaster, cutout should be made from below

to avoid chipping plaster.

5. Install housing, connect wiring and ducting, install sensor unit,

install power unit/blower assembly and install grille.

SENSOR COVER TABS

SENSOR
UNIT

JUNCTION 
BOX COVER

TIMER ADJUSTMENT

FIGURE 2

JUNCTION BOX 

WIRING CONNECTIONS

BLACK

BLACK

BLACK

WHITE

WHITE

WHITE

BLUE

MOTOR PLUG

CONNECTOR

120 VOLT

AC SUPPLY

Отзывы: