Broan-NuTone LLC Hartford, Wisconsin www.nutone.com 888-336-3948
PERFORMANCE RATINGS
MODEL QTXEN110S
VENTILATOR
AMPS
Model
Amps*
QTXEN110S
0.3
WEIGHT
Model
Shipping
Weight
QTXEN110S 12.2 lbs.
*
Total connected load
AIR FLOW PERFORMANCE
MODEL QTXEN110S
TYPICAL SPECIFICATION
Ceiling Ventilator shall be NuTone Model QTXEN110S.
The unit will have a control that will automatically turn fan ON
when humidity increase is rapid to moderate (user adjustable), or
when humidity is higher than user-adjustable set-point (50%-80%
Relative Humidity), or when supply power is cycled from ON (for
more than a second) to OFF (for less than a second) and back
ON. It shall be user-adjustable to turn OFF 5 to 60 minutes after
humidity has stabilized and is below user-adjustable set-point,
or after manually initiated by supply power cycling.
Ceiling Ventilator shall have corrosion resistant galvanized steel
housing with four-point mounting capability. It shall be ducted to
a roof or wall cap using 6” round ductwork.
Blower assembly shall be removable, have a centrifugal-type blower
wheel and a permanently lubricated motor designed for continuous
operation.
Non-metallic damper/duct connector shall be included.
Air delivery shall be no less than 110 CFM and sound level no greater
than 0.7 Sones. All air and sound ratings shall be certified by HVI.
Ceiling Ventilator shall be Energy Star® qualified and have an energy
efficient permanent split capacitor motor.
Ceiling Ventilator shall be U.L. Listed for use over bathtubs and
showers when connected to a GFCI protected branch circuit.
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0
10
20
30
40
50
60
70
80
90 100 110 120 130
Air flo w (cfm )
P
s
(
in
.
w
.g
.)
HVI-2100 CERTIFIED RATINGS comply with new
testing technologies and procedures prescribed
by the Home Ventilating Institute, for off-the-shelf
products, as they are available to consumers.
Product performance is rated at 0.1 in. static
pressure, based on tests conducted in a state-of-
the-art test laboratory. Sones are a measure of
humanly-perceived loudness, based on laboratory
measurements.
HVI PERFORMANCE
Static
Fan
Model
Pressure (Ps) CFM Sones Watts
QTREN110S
0.10
110
0.7
33.5
0.25
90