Page 4
MODEL QTXEN080C
SERVICE PARTS
30042345
Key No.
Part No.
Description
1
97016466 Housing
2
97017187 Duct
Connector-6”
3
98010102 Wiring
Plate
4
99170245
Screw, #8-18 X .375 (2 req’d)
5
97016932 Wire
Panel/Harness
Assembly
6
99020284 Blower
Wheel
7
99080562 Motor
(QTXEN080C)
8
99100491 Isolator
(4
req’d)
9
97016468 Motor
Plate
10
99250959
Washer #8 (4 req’d)
11
99260558
Nut, Hex Lock #8-32 (4 req’d)
*
97016588 Blower
Assembly
(QTXEN080C)
15
99140199
Grille Spring (2 req’d)
16
97016460
Grille Assembly (includes key no. 13)
17
99111293 Spacer
(2
supplied)
18
97016909 Hanger
Bar
Kit
TAB
Order service parts by “Part No.” - not by “Key No.”
SERVICE NOTE
To remove Blower Assembly: Unplug motor (7). Remove screw (4)
from motor plate (9) fl ange. Find the single
TAB
on the motor plate (located next to
the receptacle). Push up near motor plate tab while pushing out on side of housing. Or
insert a straight-blade screwdriver into slot in housing (next to tab) and twist screwdriver.
INSTALL GRILLE
6. Attach grille
to housing.
Squeeze
grille
springs and insert
them into slots on
each side of hous-
ing.
7. Push grille
against ceil-
ing.
5. Finish ceiling.
Install ceiling material. Cut out around housing.
4. Connect electrical wiring.
Run 120 VAC house wiring to installation location. Use
proper UL approved connector to secure house wiring to
wiring plate. Connect wires as shown in wiring diagrams.
CONNECT WIRING