GRILLE INSTALLATION

1. 

Refer to Figure 8.

Compress grille mounting springs 

and insert into slots in the housing.

2. Press grille firmly into place against ceiling.

MAINTENANCE

WARNING:

Risk of fire or electrical shock; disconnect the power

before cleaning or performing any maintenance on the ventilator.

If the grille becomes soiled, use only a mild soap and water
solution for cleaning. Do not use solvents or abrasive cleaners.

INSTALLATION IN 
EXISTING CONSTRUCTION

Installing a ventilator in an existing construction site requires 

at least a small accessible area (attic or crawl space) above 
the planned installation location.

Review “INSTALLATION IN A NEW CONSTRUCTION SITE” 

and follow all instructions which apply to your installation.

LOCATION:

Locate ventilator next to a ceiling joist.

WIRING AND DUCTING: Refer to Figure 6 for wiring and 

to Figure 2 for ducting.

Plan ducting and wiring before proceeding

with installation.

CAUTION:

Check the area above the planned installation 

to be certain that:

1. Ductwork can be installed.
2. Wiring can be run to the planned location.
3. No wiring or other obstruction will interfere with the installation.

INSTALLATION FROM ACCESSIBLE
AREA ABOVE (using headers)

Refer to Figure 9.

1. From below the installation site, drill a small hole in ceiling at 

the planned location. Stick clothes hanger through hole to help
locate it.

2. Locate hole in attic or crawl space.
3. In attic or crawl space, mark ceiling for cutout by using the

housing as a template. Cutout dimensions: 10

3

16

" x 14

1

2

". 

The short side (10

3

16

") of the cutout must be right next to 

the ceiling joist.

4. Mark cutout along marked line.

NOTE: If ceiling is plaster, cutout should be made from

below to avoid chipping plaster.

5. Install headers between joists using nails or screws leaving 

10

3

16

" between them.

6. Install brackets upside down on housing's long dimension using

hex nuts.

7. Mount damper section to housing, install housing and connect

wiring and ductwork. Install power unit/blower assembly and grille.

FIGURE 7

FIGURE 8

FIGURE 9

MOUNTING
BRACKET

HOOK HANGER
RODS FROM INSIDE
TO OUTSIDE

HANGER ROD

POWER UNIT

SLOT

HANGER
ROD

MOUNTING
SPRING

MOUNTING
BRACKET

HEADER

HEADER

SPRING
MOUNTING
CLIP

Содержание QT150

Страница 1: ...in accordance with all applicable codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back draft Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American S...

Страница 2: ...mount appropriate wall or roof cap optional Refer to the instructions provided with the caps IMPORTANT Be certain there are not any obstructions at the discharge of the ventilator Be certain insulation does not get into the ductwork or into the blower WIRING NOTE All wiring connections must comply with local codes ordinances and the National Electrical Code and the ventilator must be properly grou...

Страница 3: ...hat 1 Ductwork can be installed 2 Wiring can be run to the planned location 3 No wiring or other obstruction will interfere with the installation INSTALLATION FROM ACCESSIBLE AREA ABOVE using headers Refer to Figure 9 1 From below the installation site drill a small hole in ceiling at the planned location Stick clothes hanger through hole to help locate it 2 Locate hole in attic or crawl space 3 I...

Страница 4: ...to you NUTONE S OBLIGATION TO REPAIR OR REPLACE AT NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or excl...

Страница 5: ...t aux codes en vigueur notamment en ce qui concerne les normes de protection contre les incendies B Pour éviter les retours d air les appareils de chauffage doivent avoir suffisamment d air pour assurer une combustion et une évacuation appropriées des gaz Suivre les directives du fabricant de l appareil de chauffage ainsi que les normes de sécurité édictées par des organismes comme la National Fir...

Страница 6: ...n chaperon mural ou de toit en option Voir les instructions comprises avec les chaperons IMPORTANT S assurer que rien ne gêne l évacuation du ventilateur S assurer aussi qu aucun élément d isolation ne pénètre dans la gaine ou dans un des rotors CABLAGE REMARQUE Tous les raccords de câblage doivent respecter les règlements locaux et le ventilateur doit être convenablement relié à la terre 1 Voir F...

Страница 7: ...ation adéquate 2 Le câble puisse être amené jusqu à l emplacement choisi 3 Aucun câblage ou autre construction ne gêne l installation INSTALLATION PAR L ESPACE ACCESSIBLE AU DESSUS en utilisant des cheviêtres Voir Figure 9 1 Par en dessous percer un trou une petite dans le plafond à l emplacement prévu Introduire une petite tige par le trou pour le retrouver plus facilement 2 Localiser le trou dan...

Страница 8: ...PROPRE DISCRÉTION DE TOUT PRODUIT OU PIÈCE DÉFECTUEUX CONSTITUE LE SEUL REMÈDE DE L ACHETEUR EN VERTU DE CETTE GARANTIE NUTONE NE PEUT ÊTRE TENUE RESPONSABLE DES DOMMAGES INDIRECTS CONSÉCUTIFS OU SPÉCIAUX ATTRIBUABLES À L UTILISATION OU AU RENDEMENT DU PRODUIT Certains états ne reconnaissent pas les restrictions ni les exclusions relatives aux dommages indirects consécutifs ou spéciaux il se pourr...

Отзывы: