Grounding Instructions – This appliance must be grounded. If it should malfunction or break 
down, grounding provides a path of least resistance for electric current, to reduce the risk 
of electric shock. This appliance is equipped with a cord having an equipment-grounding 
conductor and grounding plug. The plug must be plugged into an appropriate outlet that is 

properly installed and grounded in accordance with all local codes and ordinances.

WIRING

This appliance is for use on a standard 120 VAC, minimum dedicated 20-amp branch circuit 
with a NEMA 5-15R receptacle. Make sure that the power unit is connected to an outlet 
and has a grounding attachment plug that looks like the plug shown in illustration below. No 
adapter should be used with this power unit.

NOTE: 

Inlet leads to be connected to power unit low voltage tabs using crimp connectors 
(included in parts bag) and low voltage harness.

GROUNDING INSTRUCTIONS

    

WARNING

!

Improper connection of the equipment-grounding conductor can result in 
a risk of electric shock. Check with a qualified electrician or service person 
if you are in doubt as to whether the outlet is properly grounded. Do not 
modify the plug provided with the appliance – if it will not fit the outlet, have 
a proper outlet installed by a qualified electrician.

AE0044

I

NLET

C

RIMP

 

CONNECTORS

 

TO

BE

 

CONNECTED

IN

 

LOW

 

VOLTAGE

TABS

I

NLET

I

NLET

T

O

 

OTHER

INLETS

M

ODEL

 376-UL 

(18/2) 

LOW

 

VOLTAGE

 

WIRE

I

NLET

 

LEADS

G

ROUNDED

 

OUTLETS

G

ROUNDING

 

PIN

Содержание PP500

Страница 1: ...USER GUIDE CENTRAL VACUUM POWER UNITS PP500 PP600 PP650 AB0039 FOR RESIDENTIAL USE ONLY 30042509E MODELS SFDB DQ SFDB DR AND SFDB DS PUREPOWER SERIES...

Страница 2: ...ning blocked keep free of dust lint hair and anything that may reduce air flow 2 Ensure air flows freely and exhausts unobstructed from top or side outlet 3 Do not use without filter or filters accord...

Страница 3: ...has a grounding attachment plug that looks like the plug shown in illustration below No adapter should be used with this power unit NOTE Inlet leads to be connected to power unit low voltage tabs usi...

Страница 4: ...oss of suction is caused by a blockage in the system changing the bag or emptying the debris pail will solve the problem NOTE Even if not filled to capacity if the bag seems tightly stretched when rem...

Страница 5: ...POWER UNITS ONLY To remove Remove the pail from the unit To remove the permanent filter use pull tab A located on edge of filter to pull and loosen filter from inlet chamber wall Squeeze from both sid...

Страница 6: ...removed PP600 and PP650 units only Simply brush filter clean If the filter is excessively soiled hand wash in a water and mild detergent solution rinse and let it dry completely on a flat surface befo...

Страница 7: ...art and pulling on upper part to disengage it NOTE A small flat blade screwdriver can also be used to pry on the 4 retaining tabs as shown in illustration A at the bottom of the page Discard the used...

Страница 8: ...SERVICE PARTS PP650 UNIT PP500 AND PP600 UNITS 8 AL0021 7 15 10 17 8 9 11 1 3 12 13 14 1 2 4 5 6 16...

Страница 9: ...P CAP ASSEMBLY 1 S10941411 PP500 TOP CAP ASSEMBLY 1 2 S10941416 PP650 EXHAUST HEPA FILTER 1 3 S10941413 PP650 TOP CAP ASSEMBLY INCLUDING ITEM 5 LOWER PART 1 4 S10941419 MOTOR WITH UPPER AND LOWER FOAM...

Страница 10: ...sable bag torn Wall inlet cover not properly sealed Exhaust tubing or vent clogged Change the disposable bag or empty debris pail as described on page 5 Replace the debris pail gasket Disconnect the h...

Страница 11: ...as occured somewhere in the system Set the unit power switch to OFF position Perform a complete check of all wall inlets and power unit low voltage control leads connections Contact your authorized Se...

Отзывы: