NuTone IM-440 Series Скачать руководство пользователя страница 12

12

OPERATIONAL CHECKOUT

SCAN:

Activates scan tuning during AM/FM operation.

▲▼ 

UP/DOWN TUNING:

Provides manual tuning of the AM/FM radio.

MEMORY 1-6 KEYS:

Provides direct access to stored radio

frequencies.

TRACK

: Returns to the beginning of the current track and/or previous

tracks.

TRACK

: Advances the CD Player to the beginning of the next track.

RDM/RPT:

(Random/Repeat) Set the CD play mode to: REPEAT ONE,

REPEAT ALL or RANDOM PLAY.

PLAY/PAUSE:

Activates the operation of the CD Player. Pressing the

key during play operation will pause the CD Player.

SEARCH

: Quickly searches the track in the forward direction.

SEARCH

: Quickly searches the track in the reverse direction.

CD PLAYER DOOR:

Open CD door and snap CD disc onto spindle.

TIME SET:

Used with the 

▲ ▼

keys to set the clock and timer.

MEMORY SET:

Stores desired radio frequencies into a selected

memory location.

CLOSE:

Press here to close CD Player door.

TREBLE:

Adjusts the high frequency audio content of the source audio.

STOP:

Ends the CD Play mode and turns off the program audio.

BASS:

Adjusts the low frequency audio content of the source audio.

SYSTEM VOLUME:

Adjusts the program audio level throughout the

system.

OPEN:

Causes the CD Player door to open.

LOUDNESS:

Compensates for the bass and treble response the human

ear has when listening to audio at low volume levels.

MICROPROCESSOR RESET:

Initiates a reset of the microprocessor.

NOTE:

A reset of the microprocessor will erase the system’s memory. 

DISPLAY:

Sets the LCD display mode: CLOCK, RADIO FREQUENCY,

TRACK NUMBER or TIME PLAYED.

INTERCOM VOLUME:

Adjusts intercom audio level throughout the

system.

MASTER STATION STATUS SWITCHES:

Sets the master station in

one of the following modes: RADIO/INTERCOM, INTERCOM ONLY,
OFF or MONITOR.

REMOTE STATION STATUS SWITCHES:

Sets the remote stations in

one of the following modes: RADIO/INTERCOM, INTERCOM ONLY,
OFF or MONITOR. Note: If the optional expansion module is installed, 6
additional switches will be located on the right side of the master.

DOOR RELEASE KNOCKOUT:

Mounting hole for optional door

release pushbutton.

END CALL:

Ends intercom communication and returns system to audio

source.

DOOR TALK:

Initiates intercom communication to the door speakers.

INSIDE/PATIO:

Initiates intercom communication to remote stations.

TIMER:

Enables or disables the radio timer. The indicator light will

illuminate next to the Timer key when the Radio Timer is activated.

PROGRAM AUDIO SOURCE:

Selects the program audio source: AM,

FM, TAPE and AUX. The indicator light will illuminate next to the
selected program audio source.

ELECTRONIC CHIME TUNE SELECTION:

Selects the tune of the

optional NuTone IA-29 Chime Module. 

PROGRAM OFF:

Turns off the selected program audio source. The

program Off key does not affect the intercom or chime operation.

MASTER VOLUME: 

Adjusts the volume at the master station.

1

2

3

4

5

6

7

8

9

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

10

SYSTEM OPERATING CONTROLS

1

2

3

4

5

6

7

8

9

11

12

13

14

15

16

17

18

19

20

10

21

22

23

24

25

26

27

28

29

30

31

32

33

Содержание IM-440 Series

Страница 1: ...5 PATIO SPEAKER W CONTROLS NUTONE IW 2 NUTONE IW 6 300 MAX DOOR SPEAKER MODELS WITH CHIME PUSHBUTTON ALSO REQUIRE 18 2 S 143 TO CHIME LOCATION OR IW 2 TO MASTER IF CHIME MODULE IS USED IA 6C RECEPTACL...

Страница 2: ...ter Station to the Terminal Board 8 Connecting the Radio Antenna 9 Connecting the Optional Chime Module 9 Connecting Optional Electronic Chime 9 Connecting Optional Accessories 10 Connecting Power to...

Страница 3: ...ule Use NuTone S 143 18 ga twisted pair for connecting Pushbutton to electronic chime Electronic chime to chime transformer Use N 14 2 power cable with ground Class 1 UL Listed Observe local codes for...

Страница 4: ...WHT ORN to ORN ORN WHT to ORN WHT Only connect one remote to each set of screw terminals After completing all connections check for any shorted wires Dress cables flat against the terminal board to a...

Страница 5: ...ition the master station face up Be careful not to damage the cables on the back of the unit 1 Refer to Figure 6 Open the left hand door on the master station panel 2 Cut the 4 retainer webs from the...

Страница 6: ...o it is flush with the wall surface flush with rough in frame if the rough in is installed after the wall board Tighten all eight 8 screws 2 Refer to Figure 10A and 10B For rough in frames which are r...

Страница 7: ...NECTING SCREWS OF THE TRANSFORMER OR THE TRANSFORMER WILL BE DESTROYED CAUTION BE SURE THE AC POWER IS OFF BEFORE CONNECTING THE POWER TRANSFORMERS DO NOT TURN AC POWER ON TO TRANSFORMERS UNTIL ALL WI...

Страница 8: ...11 unless IA 440 expansion module is used 2 Make sure the alignment keys are properly aligned before applying pressure to the connector 3 After all connectors are plugged into the terminal board posit...

Страница 9: ...ocations between ends to prevent sagging NOTE Any excess antenna cable should be located outside of Rough in INSTALLATION Continued CONNECTING THE OPTIONAL CHIME MODULE It is now time to connect the o...

Страница 10: ...pe of installation can be used for example in a doctor s office where intercom and music are desired in the office area but music only is desired in the waiting room NOTE If an auxiliary amplifier is...

Страница 11: ...0 PM Refer to the Operational Checkout section of this manual for additional information MOUNTING AND CONNECTING OPTIONAL DOOR RELEASE PUSHBUTTON You have previously prepared the master station for th...

Страница 12: ...will erase the system s memory DISPLAY Sets the LCD display mode CLOCK RADIO FREQUENCY TRACK NUMBER or TIME PLAYED INTERCOM VOLUME Adjusts intercom audio level throughout the system MASTER STATION STA...

Страница 13: ...tations in the system 4 Press the DOOR TALK key Radio audio will mute and audio from the initiating station will be heard at the door speaker s and all stations in the system 5 Release the DOOR TALK k...

Страница 14: ...clockwise as viewed from the rear of the master station panel This adjustment will reduce the intercom gain 2 To increase the intercom gain turn the internal control clockwise OPERATIONAL CHECKOUT Con...

Страница 15: ...g in this order 1 key 3 Memory 3 key 2 key 4 Release all keys RESETTING THE MICROPROCESSOR NOTE Resetting the microprocessor will cause the radio memory channels and clock time to be lost Should the s...

Страница 16: ...TIONAL CHECKOUT This unit contains a protection device which opens if the audio amplifier detects an overload condition If the music chime and intercom audio becomes weak and distorted remove power fr...

Страница 17: ...T be heard at stations selected to the OFF or MONITOR Be certain the electronic chime is properly connected to the master station s electronic chime input screw terminals Adjust the volume of the elec...

Страница 18: ...soft cotton cloth Wipe the disc from the center to the outside edge Never use paint thinner Benzene or conventional record cleaners Cannot receive radio station which is received by another radio in...

Страница 19: ...19...

Страница 20: ...NUTONE S OBLIGATION TO REPAIR OR REPLACE AT NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DA...

Отзывы: