background image

EZ80NC 

  

Installation Guide

Page 6

Installation - Replace an Existing Fan

120 VAC

LINE IN

ON/OFF

SWITCH

(purchase separately)

KNOCKOUT

PLATE

RECEPTACLE

120 VAC LINE IN

SWITCH BOX

BLACK

WHITE

GROUND (green or bare)

Connect house wiring to 
wiring plate with UL approved 
connector.

Connect wiring as
shown in diagrams.

Attach wiring plate and wiring 
cover to inside of housing with 
screws provided.

Plug blower 
into receptacle 
and re-install 
blower. Tighten 
blower screws.

7

 Connect Electrical Wiring

8

 Replace Blower

9

  Install Grille

Squeeze
grille springs
and insert
into slots in
blower.

1

Push grille up against ceiling.

2

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING:

If unfamiliar with electrical wiring, secure the services of a 
qualified person to connect wiring according to all applicable 
codes and standards.

Содержание EZ80NC

Страница 1: ...ner Register your product online at www nutone ca register asp Easy installation Table of Contents Warnings and Cautions 2 Operation 2 Cleaning and Maintenance 2 Troubleshooting 2 Typical Installation 2 Installation Replace an Existing Fan 3 Installation New Construction 7 Service Parts 8 Warranty 8 2014 Broan NuTone LLC ...

Страница 2: ... in a sloped ceiling the duct connector must point up 4 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 5 Please read specification label on product for further information and requirements 45 45 NOT FOR USE IN A COOKING AREA Do not install above or inside this area Floor Cooking Equipment Purchase separately INSULATION Pl...

Страница 3: ...erformance Use of other ducting is acceptable but may impact performance Existing metal duct will require the addition of a short lenght of flexible duct Roof cap or wall cap built in damper recommended Tape to seal duct connections Drywall screws or sheet metal screws optional Electrical wiring and supplies per local code requirements 1 Remove from Packaging 2 Prepare the Housing Loosen 2 blower ...

Страница 4: ... O N O F N E W F A N S D U C T C O N N E C T O R For retrofit installations Place this edge against ceiling framing See installation instructions Mark center line of existing fan on ceiling 2 Position template over existing fan with arrow on center line 3 4 Trace around outside of template with a pencil 7 1 Use a drywall saw to cut out ceiling material where marked WARNING Be careful to avoid cutt...

Страница 5: ...sing and move downward on top of ceiling material to properly secure housing in place Minimum ceiling thickness to be 1 2 CAUTION Do not overtighten clamps with a power driver Ceiling material may become deformed and prevent proper installation 1 Pull ductwork into housing and use duct tape to attach it to duct connector For 3 ductwork use the 4 to 3 reducer provided See below 2 Insert duct connec...

Страница 6: ...ate and wiring cover to inside of housing with screws provided Plug blower into receptacle and re install blower Tighten blower screws 7 Connect Electrical Wiring 8 Replace Blower 9 Install Grille Squeeze grille springs and insert into slots in blower 1 Push grille up against ceiling 2 WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING If unfamiliar with e...

Страница 7: ... fan against ceiling framing so that bottom edge of housing will be flush with finished ceiling Use 4 screws to attach housing to framing Optional for additional support After ceiling is finished rotate the tightening clamps as described on Page 5 Attach housing to 2 x 6 or greater joists Use additional blocking as needed JOISTS I JOISTS TRUSSES ADDITIONAL BLOCKING 1 Remove from Packaging see Page...

Страница 8: ...prohibited or invalid such provision shall be ineffective only to the extent of such prohibition or invalidity without invalidating the remainder of such provision or the other remaining provisions of the Limited Warranty Remedy During the applicable limited warranty period the Company will at its option provide replacement parts for or repair or replace without charge any Product or part thereof ...