background image

DECORATIVE VENTILATION 
FAN WITH LIGHT

READ AND SAVE THESE INSTRUCTIONS

TYPICAL INSTALLATIONS

HOUSING

GRILLE

PAN

GLASS

LIGHT SHADE

CEILING

JOIST

CEILING

MATERIAL

HOUSING

HOUSING MOUNTED

DIRECTLY TO  JOIST

2” x 6” (or larger) 

Discharge parallel to joists.

HOUSING

HOUSING

2” x 4”

CEILING
JOIST or

TRUSS

2” x 4”

CEILING
JOIST or

TRUSS

CEILING

MATERIAL

GRILLE

PAN

GLASS

LIGHT SHADE

HOUSING MOUNTED

TO 2” x 4” TRUSS

Discharge parallel to joists.

HOUSING

HOUSING

ADDITIONAL

FRAMING*

"

I

"

JOIST

"

I

"

JOIST

GRILLE

PAN

GLASS LIGHT SHADE

CEILING

MATERIAL

HOUSING MOUNTED TO “I” JOIST

Requires additional framing

for mounting.

Discharge parallel to joists.

*

 Additional framing must be a 2” x 6” (minimum height), at least 9 inches long.

WARNING  

 

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer.

If you have questions, contact the manufacturer at the 
address or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 
power from being switched on accidentally. When the service 
disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by a qualified 

person(s) in accordance with all applicable codes and standards, 
including fire-rated construction codes and standards.

4.  Sufficient air is needed for proper combustion and exhaust-

ing of gases through the flue (chimney) of fuel burning 
equipment to prevent backdrafting. Follow the heating 
equipment manufacturer’s guideline and safety standards 
such as those published by the National Fire Protection 
Association (NFPA), and the American Society for Heating, 
Refrigeration and Air Conditioning Engineers (ASHRAE), 
and the local code authorities.

5.  When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  Do not install in a tub or shower enclosure.
8.  Not for use in kitchens.
9.  This unit must be grounded.
10. This unit is U.L. listed. Type I.C. inherently protected.
11. When applicable local regulations comprise more 

restrictive installation and/or certification requirements, 
the aforementioned requirements prevail on those of this 
document and the installer agrees to conform to these at 
his own expenses.

12. When performing installation, servicing or cleaning this unit, 

it is recommended to wear safety glasses and gloves.

CAUTION  

!

1.  For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

2.  This product is designed for installation in FLAT CEILINGS 

ONLY. Do not mount this product in a wall.

3.  The light fixture assembly must be mounted to the fan 

housing assembly included with this product. Do not mount 
the light fixture assembly to a wiring outlet box.

4.  To avoid motor bearing damage and noisy and/or 

unbalanced impellers, keep drywall spray, construction 
dust, etc. off power unit.

5.  Please read specification label on product for further 

information and requirements.

PLAN THE  INSTALLATION

Installer: Leave this manual with the 
homeowner.
Homeowner: Use and Care 
information on page 4.

ROOF CAP*

(with built-in

damper)

WALL CAP*
(with built-in

damper)

Keep duct 

runs short

4-IN. ROUND 

ELBOWS*

Seal duct 

joints with

tape.

4-IN. ROUND 

DUCT*

Seal gaps

around

housing.

POWER

CABLE*

FAN

HOUSING

INSULATION

(Place around and 

over fan housing.)

*Purchase 
separately.

Register your product 

online at www.nutone.ca

OR

OR

Page 1

MODEL 788CHNTC 