MODEL  773BNNT 

3. Set housing 

aside and drive 

nails partially 

into joist at the 

top of both key-

hole marks.

4. Hang housing from 

nails and pound 

nails tight. To en-

sure a noise-free 

mount, pound an-

other nail through 

the top hole of each 

mounting tab.

Existing Construction

2. In  attic,  position  mounting  brackets  against  joist. Trace 

outline of housing on ceiling material.

1.  Choose the location for your fan/light in the ceiling. For best 

possible performance, use the shortest possible duct run 

and a minimum number of elbows.

3. Set housing aside and cut ceiling opening slightly larger 

than marked.

INSTALL THE HOUSING

1. Choose the location for your fan in the ceiling. For best 

possible performance, use the shortest possible duct run 

and a minimum number of elbows.

2. Position mounting brackets against joist so that bottom  

edge of housing will be flush with finished ceiling.

Additional positioning feature for 5/8”, 1”, &

1-1/4” thick ceiling material:

Holes in corners of housing are labeled with various 

ceiling material thicknesses. Position housing so 

bottom edge of joist is visible through a matched 

set  of  holes. The  housing  is  now  in  the  proper 

position for that ceiling material thickness.

Additional  positioning  feature  for  1/2”  thick 

ceiling material:

Bend two tabs, on side of housing, 90

0

 outward. Lift 

housing until tabs contact underside of joist.

Mark the keyhole slot on both mounting brackets.

New Construction

5/8

1

1-1/4

TAB

HOLES

BOTTOM EDGE OF JOIST

- PLEASE NOTE -

THE FOLLOWING INSTALLATION ILLUSTRATIONS SHOW 2 X 

6 JOISTS. IF YOU HAVE A TRUSS OR “I”-JOIST INSTALLATION, 

MOUNT THE VENTILATOR TO THE ADDITIONAL FRAMING IN 

THE SAME MANNER. (Additional framing must be a 2x6 (mini-

mum height), at least 9-inches long.)

4. Place housing in opening so that its bottom edge is flush  

with finished ceiling. Nail to joist through keyhole on both 

sides. To ensure a noise-free installation, drive another nail 

through the top hole of each mounting bracket. 

5. Additional  mounting  holes  are  provided  for  installations 

where access from above is inconvenient or not possible. 

Nail or screw housing directly to joists or framing.
Recommended: Seal between ceiling material & housing 
on all 4 sides to prevent air leakage.

ADDITIONAL

MOUNTING

HOLES

RECOMMENDED: SEAL BETWEEN

CEILING MATERIAL & HOUSING (4 SIDES)

Содержание 773BNNT

Страница 1: ...needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standa...

Страница 2: ...ousing so bottom edge of joist is visible through a matched set of holes The housing is now in the proper position for that ceiling material thickness Additional positioning feature for 1 2 thick ceil...

Страница 3: ...h a roof or wall cap Check damper to make sure that it opens freely Tape all duct connections to make them secure and air tight 1 Wire unit following diagram above Run electrical cable as direct as po...

Страница 4: ...n or part thereof to the extent NuTone finds it to be covered by and in breach of this limited warranty NuTone will ship the repaired or replaced Fan or replacement parts to you at no charge You are r...

Страница 5: ...Aire American Society for Heating RefrigerationandAirConditioningEngineers ASHRAE y los c digos locales ditioning Engineers ASHRAE y las autoridades de los c digos locales 5 Cuando corte o perfore la...

Страница 6: ...ra en la posici n adecuada para ese espesor del material del cielo raso Caracter stica adicional para la colocaci n en material de cielo raso de 1 3 cm Doble a 90 y hacia afuera las dos aletas que se...

Страница 7: ...a que el cable toque los costados ni la parte superior de la unidad despu s de que la instalaci n est terminada DIAGRAMA EL CTRICO N E G R O C O M M V E N T A Z U L N E G R O B L A N C O L A M P B L N...

Страница 8: ...repuesto o reparar o reemplazar sin cargo alguno cualquier ventilador o pieza del mismo hasta el grado en que NuTone lo encuentre cubierto bajo esta garant a limitada y en incumplimiento de la misma...

Отзывы: