EXISTING CONSTRUCTION

1.  Choose  the  location  for  your 

fan  in  the  ceiling.  For  best 

possibleperformance,  use  the 

shortest possible duct run and 

a minimum number of elbows.

2.  In  attic,  position  mounting 

brackets  against  joist.  Trace 

outline  of  housing  on  ceiling 

material.

3.  Set housing aside and cut ceil-

ing opening slightly larger than 

marked.

4.  Place  housing  in  opening  so 

that  its  bottom  edge  is  flush 

with  finished  ceiling.  Nail  to 

joistthrough  keyhole  on  both 

sides. To  ensure  a  noise-free 

installation, drive another nail 

through the top hole  of each 

mounting bracket.

5.  Additional  mounting  holes 

are  provided  for  installations 

where  access from above is 

inconvenient  or  not  possible. 

Nail or screw  housing directly 

to joists or framing.

INSTALL THE DUCTWORK

1.  Snap the damper/duct connector onto housing. Make sure that 

tabs on the connector lock into slots in housing. Top of damper/

duct connector should be flush with top of housing.

2.  Connect 4” round duct to damper/duct connector and extend 

duct to outside through a roof or wall cap. Check damper to 

make sure that it opens freely. Tape all duct connections to 

make them secure and air tight.

NEW CONSTRUCTION

1.  Choose the location 

for your fan in the ceil-

ing. For best possible 

performance, use the 

shortest possible duct 

run and a minimum 

number of elbows.

2.  Position mounting 

brackets against joist 

so that bottom edge of 

housing will be flush with finished ceiling.

Additional positioning feature for 5/8”, 1”, & 1-1/4” thick ceiling 

material:  

Holes in corners of housing are labeled with various 

ceiling  material  thicknesses.  Position  housing  so  bottom  edge 

of joist is visible through a matched set of holes. The housing 

is now in the proper position for that ceiling material thickness.

Additional positioning feature for 1/2” thick ceiling material:

Bend two tabs, on side of housing, 90° outward.  Lift housing until 

tabs contact underside of joist.  Mark the keyhole slot on both 

mounting brackets.

3.  Set housing aside and drive nails 

partially  into  joist  at  the  top  of 

both keyhole marks.

4.  Hang  housing  from  nails  and 

pound  nails  tight. To  ensure  a 

noise-free mount, pound another 

nail through the top hole of each 

mounting tab.

5/8

1

1-1/4

BOTTOM EDGE OF JOIST

ADDITIONAL MOUNTING 

HOLES

FLUSH

INSTALL THE HOUSING

- PLEASE NOTE -

THE FOLLOWING INSTALLATION ILLUSTRATIONS SHOW 

2 X 6 JOISTS. IF YOU HAVE A TRUSS OR “I”-JOIST INSTAL-

LATION, MOUNT THE VENTILATOR TO THE ADDITIONAL 

FRAMING  IN THE  SAME  MANNER.  (Additional  framing 

must be a 2x6 (minimum height), at least 9-inches long.)

HOLES

TAB

Содержание 50NT

Страница 1: ...edes all prior warranties To qualify for warranty service you must a notify Broan NuTone at the address or telephone number below b give the model number and part identification and c describe the nat...

Страница 2: ...t HOUSING 2 x 4 CEILING JOIST or TRUSS MOUNTING TABS GRILLE CEILING MATERIAL POWER CABLE ADDITIONAL FRAMING 2 x 4 CEILING JOIST or TRUSS HOUSING CEILING JOIST MOUNTING TABS GRILLE CEILING MATERIAL POW...

Страница 3: ...CONSTRUCTION 1 Choose the location for your fan in the ceil ing For best possible performance use the shortest possible duct run and a minimum number of elbows 2 Position mounting brackets against jo...

Страница 4: ...bare WIRING PLATE 120 VAC LINE IN RECEPTACLE GRILLE SPRING SLOT IN MOTOR PLATE 1 3 8 6 9 10 2 11 7 4 5 12 SERVICE PARTS KEY NO PART NO DESCRIPTION 1 97018333 Grille Assembly 2 97018310 Motor Plate As...

Страница 5: ...qui varient d une province l autre ou d un tat l autre Cette garantie annule toutes les garanties pr c dentes Pour le service sous garantie vous devez a aviser Broan NuTone l adresse ou num ro de t l...

Страница 6: ...ER BO TIER SOLIVE DU PLAFOND BRIDES DE MONTAGE GRILLE MAT RIAU DU PLAFOND FIL D ALIMENTATION BO TIER FIX DIRECTEMENT AUX SOLIVES de 2X6 ou plus BO TIER FIX AUX FERMES DE 2X4 Les brides de montage exig...

Страница 7: ...nts avec du ruban adh sif CONSTRUCTION NEUVE 1 Choisissez l emplacement du ventilateur au plafond Pour obtenir un rendement optimal utilisez un minimum de conduits et de coudes 2 Positionnez les bride...

Страница 8: ...RIPTION 1 97018333 Ensemble de grille 2 97018310 Ensemble de plaque de moteur 3 99080656 Moteur 50NT 99080634 Moteur 80NT 4 99020300 Ensemble de roue ailettes 5 99260425 crou de moteur crou de s curit...

Отзывы: