OPI-POWER LIFT HF 3S 8000-V1.0-EN
27
Emergency discharge:
• Push on the black cap (21) of the valve and at
the same time slowly pull the operating lever (9).
The lowering procedure begins immediately. Low-
ering speed can be varied by the lever position.
• The lowering process must be continuously ob-
served.
• Release the operating lever (9) to stop or if there
is a danger.
• Lower the lift to the lowest position.
• Release the latch again (remove cable tie)
• Only operate the lift if it is in seamless condition
from a safety point of view.
•
If required, firstly inform customer service.
6.2 Moving onto an obstacle
If the lifting rails or lifting arms move onto an ob-
stacle due to operator inattention, the lift stops
in place. To remove the object, raise the lift to a
height where the object can be removed.
7
Maintenance and care of the lift
i
Before maintenance, do all preparation work so
there is no danger to life or limb or object dam-
age during maintenance and repair work.
Value is placed on long lifetimes and safety in the
development and production of Nussbaum prod-
ucts. To guarantee the safety of the operator, prod-
uct reliability, low running costs, keep the warranty
and also the long-lifetime of the product, proper
set up and operation is just as important as regular
maintenance and sufficient care.
Our platforms fulfil or exceed all safety standards of
the countries we supply to. For example, Europe
-
an regulations require a service by qualified experts
every 12 months of work of the platform. To guar-
antee the largest possible availability and function-
al capacity of the lift system, ensure the list of any
cleaning, care and maintenance work is done.
After first commissioning the lift is to be serviced at
regular intervals of a maximum of one year by an
authorized person according to the following plan.
For intensive operation and higher degree of con-
tamination shorten the service interval.
The complete function of the lift is to be observed
during daily use. Customer service must be in-
formed of any malfunctions.
Содержание HF 3S 8000
Страница 2: ...2 OPI POWER LIFT HF 3S 8000 V1 0 EN ...
Страница 4: ......
Страница 18: ...18 OPI POWER LIFT HF 3S 8000 V1 0 EN ...
Страница 19: ...OPI POWER LIFT HF 3S 8000 V1 0 EN 19 ...
Страница 20: ...20 OPI POWER LIFT HF 3S 8000 V1 0 EN ...
Страница 21: ...OPI POWER LIFT HF 3S 8000 V1 0 EN 21 ...
Страница 55: ...Made in Germany POWER LIFT HF 3S 8000 Made in Germany Spare parts list ...
Страница 66: ...66 OPI POWER LIFT HF 3S 8000 V1 0 EN Universal control with circuit board 000STA03600_1 29 05 2018 ...
Страница 71: ...OPI POWER LIFT HF 3S 8000 V1 0 EN 71 ...