Operation Manual of Cochlear Implant
1) Medical Device Registration Certificate No.: GXZZ 20173464498
2) Registered Product Standard No.: GXZZ 20173464498
3) Production License No.: ZSYJSCX No.20130030
4) Manufacturer: Zhejiang Nurotron Biotechnology Co., Ltd.
5) Address: No.17 Longtan Road, Yuhang District, Hangzhou, Zhejiang 311121, China
Registration address: No.17 Longtan Road, Yuhang District, Hangzhou, Zhejiang 311121, China
6) National Service Hotline: +86-4006-333-571
7) Website: http://www.nurotron.com
Information of CE Authorized Representative
1) CE Authorized Representative: BIOTECH INNOVATION & SOLUTIONS, S.L.
2) Address: Escoles Pies 103, 08017 Barcelona, Spain
5.1 Stores
The safety system of stores will not influence the cochlear system. But when wearers pass safety
system with speech processor on, a warning alarm will be given. To avoid misunderstandings,
please turn off speech processor when passing safety systems, or carry with an identification
card for check.
5.2 Airport security check
Security gates of some airports are provided with magnetic induction facilities, which may
cause damage to your speech processor. Please turn off speech processor when passing such
systems. The off condition will also protect your speech processor from damage by X-ray
inspection instruments.
Implant may incur alarm of metallic instruments. You may apply for inspection by portable
instruments, or pass through the passage for the handicapped.
05
Safety System
Some airlines may require passengers to turn off electronic devices when air plane takes off or lands
on. So please turn off your speech processor temporarily. You can tell stewardess that you are hearing
impaired, so that they may inform you of necessary safety measures.
06
Taking Air Plane
If body temperature of wearer of cochlear implant exceeds 39ºC, please turn off speech processor and
cochlear implant. Before implantation surgery, patients are suggested taking fitting test of hearing aid.
If patients suffer from deafness caused by infectious diseases (such as meningitis), they are advised to
take cochlear implantation immediately. To achieve the best, patients who are ready to take cochlear
implantation and their families shall be highly enthusiastic about cochlear implantation and hold a
suitable expectation. Meanwhile, they shall understand the importance of periodic fitting of speech
processor programs, evaluation and speech therapy.
07
Other information
Service and warranty: the quality warranty period of implant is 12 years starting from the date of
implantation. If your cochlear implant is used under normal conditions guided by the precautions and
direction specified in the Operation Manual and comes up with any quality problem, our company will
replace the product (same model) free of charge after identifying the necessity. Any improper use or
artificial damage is beyond the warranty scope, and a certain fee will be charged at the discretion of
Nurotron Company.
08
Warranty
09
Manufacturer's Information
conducted to the speech processor. To prevent such things, please proceed as follows:
a) When touching other people's speech processor:
Step 1 - Touch his/her body to reduce accumulation of static electricity;
Step 2 - Touch speech processor;
b) When taking up speech processor from a table:
Step 1 - Touch the table;
Step 2 - Take up speech processor
4.6 TV screen and computer screen
Please don't let speech processor contact these screens. Please periodically clean screens to
prevent accumulation of static electricity. Better use anti-static screens. If touch-sensitive display
is used, it is preferred to use a pencil with rubber on one end and touch the rubber on the screen,
instead of using your finger.
4.7 Thunder storm zone
1) If wearer of cochlear implant stands in thunder storm, please stay away from metallic
appliances and take down the speech processor.
2) If children with the implantation act restlessly in thunder storm, please help them take down the
speech processor.