68
ENGLISH
DISPLAY
CAUSE
EFFECT
SOLUTION
NOTE
The volume counter has
reached the number of litres
of deliverable water set during
programming phase.
Coffee will not be delivered;
the dose will not be halted or
it is variable.
Regenerate cleaning filter
salts. To erase the alarm see
paragraph on ‘RESETTING
CLEANING FILTER LITRE
COUNTER’.
This alarm will not halt
delivery. The cleaning
filter alarm can be elimi-
nated by programming
the number of litres to
zero (see paragraph on
‘PROGRAMMING’).
CLEANING FILTER
ALARM
One of the two temperature
probes is broken.
Coffee will not be delivered. Substitute the broken probe.
This alarm blocks all
deliveries.
TEMPERATURE PROBE
MALFUNCTION ALARM
Too much coffee.
Coffee will not be delivered
and an ejection cycle will be
effected.
Reduce the quantity of cof-
fee.
COFFEE QUANTITY
ALARM