![Numax S18GLCNDH Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/numax/s18glcndh/s18glcndh_manual_1717617006.webp)
11
10
HTTP://WWW.NUMAXTOOLS.COM 1-888-669-5672
HTTP://WWW.NUMAXTOOLS.COM 1-888-669-5672
MODEL: S18GLCNDH
MODEL: S18GLCNDH
Correct Placement
SUBFLOOR
Incorrect Placement
Lcleat
or
Staples
TONGUE & GROOVE
FLOORING
TONGUE & GROOVE
FLOORING
SUBFLOOR
Lcleat
or
Staples
NOTE:
Please follow your wood manufacture’s
guidelines when doing your flooring
installations.
When finished, make sure to store the tool
in a clean, dry, safe location out of reach of
children and other unauthorized people.
Extreme caution must be used
whenever this tool is connected to an
air source. If the tool is dropped, or if
the hammer cap (M) is accidentally
struck, then the tool will fire a fastener,
p o t e n t i a l l y c a u s i n g S E R I O U S
PERSONAL INJURY.
WARNING:
!
Keep your feet off the tool.
WARNING:
!
Before using the tool on a floor, test the
tool on a scrap piece of wood. Adjust
the driving depth by providing more or
less air pressure. Never exceed 115
PSI.
WARNING:
!
An improperly functioning tool must
not be used. Do not actuate the tool
unless the tool is placed firmly against
the work piece.
WARNING:
!
4.
Hand grip (N)
Hammer cap (M)
Disconnect the tool from air source.
Empty the magazine. Make sure all
fasteners are removed.
Try to fire the tool into a piece of scrap
wood or flooring to make sure that it’s
incapable of firing any fasteners.
Set the tool on its side to expose the Nose
Bolts(O).
Remove three Nose Bolts (O), slide the
Drive Guide(P) out to expose the jammed
fastener. (See figure 5)
Remove jammed fastener, using pliers or a
screwdriver if required. (See figure 6)
Return the Drive Blade back to its original
position. (See figure 7)
Replace the Nose Guide (P) and Nose
Bolts(O). (See figure 8)
Reconnect tool to the air source, then
reload the tool with fasteners.
Press the tool against a piece of wood, and
test fire the fasteners several times to
check for proper operation. If the tool is
properly firing, you may continue using the
tool. If the tool fails to perform properly,
immediately discontinue use and have the
tool repaired by a qualified service
technician.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
CLEARING JAMS
Occasionally, fasteners may become jammed
in the firing mechanism of the tool, making the
tool inoperable. To remove a jammed fastener,
follow these steps below:
Nose Bolts (O)
Drive guide(P)
Drive guide(P)
Drive Blade
Nose Bolts (O)
Drive guide (P)
Figure 5
Figure 6
Figure 7
Figure 8
Make sure there is no fastener in the
magazine before clearing a jam.
WARNING:
!
Frequent, but not excessive, lubrication is
required for best performance. Oil for the tool
added through the air line connection will
lubricate the internal parts.
LUBRICATION
Disconnect the tool from the air source to
add the lubricant.
MAINTENANCE
Any time inspection, maintenance, and
cleaning are done:
◆
Disconnect the tool from the air source.
◆
Empty the magazine completely.
WARNING:
!
Each tool is packed with an anti-dust cap on the
air connector, check it after unpacking.
Keep the anti-dust cap cover the air connector
when the tool is not in use.
ANTI-DUST
1.
Turn the tool so the air inlet is facing up.
Place 2-3 drops of pneumatic fastening tool
oil into air inlet. Do not use detergent oil or
additives as these lubricants will cause
accelerated wear to the seals and bumpers
in the tool, resulting in poor tool
p e r f o r m a n c e a n d f r e q u e n t t o o l
maintenance.
2.
Drive guide(P)
Jammed
Fastener