T 01460 68600

To raise the floor-tool, ensure the floor-tool carrier is central to the machine. 

Lift the lever near the base of the handle and lock into position.

Raising/Lowering the Floor-tool

Machine Operation

WHEN HANDLING CHEMICALS

Always ensure that chemical manufacturer’s safety guidelines are followed.

Only use chemicals recommended for use in auto scrubber-dryers.

!

!

IMPORTANT

Do not operate machine unless the Operator Manual has been read 

and fully understood.

!

!

To operate, set water flow rate tap, lower the floor-tool, press the vacuum / water switches, pull 

trigger(s).

The waste water is then retrieved by the suction floor-tool.

Overlap each scrubbing path by 10cm to ensure an even clean.

Do not operate the machine on slopes that exceed (2%),when full.

On heavily soiled floors use a ‘double scrub’ technique.

First pre-scrub the floor with the floor-tool in the raised position, 

allow the chemical time to work then scrub the area a second 

time with the floor-tool lowered.

If streaking occurs wipe floor-tool blades clean.

NOTE: Care must be taken to reduce speed when 

cornering or when manoeuvring around obstacles

Machine In Use

Содержание TTB 1840 36V

Страница 1: ...1 Caution Read instructions before using the machine Original Instructions TTB 1840 36V SCRUBBER DRYER www numatic co uk ...

Страница 2: ...l PPE Recycling Page 13 Information for Scrubber Dryer Page 14 Twintec Maintenance Page 15 Spare Parts Page 15 Recommended Spare Parts Page 15 Schematic Diagram Page 15 EU Declaration Document Page 16 Warranty Page 17 Company Address Page 19 SCRUBBER DRYER Index After the removal of all the packaging carefully open and check the contents Owner Manual Battery Charger Manual Battery Charger Lead Bat...

Страница 3: ...2 T 01460 68600 Machine Overview 1 6 4 2 3 9 8 7 5 13 14 15 16 12 18 19 20 17 11 10 ...

Страница 4: ...utton 3 Water Flow Indicator 4 Vacuum Off On Indicator 5 Vacuum Off On Button 6 Handle Position Lever 7 Start Switch 8 Triggers Control Panel Overview In the event of a breakdown contact your Numatic dealer or the Numatic Technical help line 44 0 1460 269268 1 4 3 5 8 8 6 7 2 TTB 1840 36V ...

Страница 5: ... pad in place Fig 4 Swing the floor tool carrier from behind the brush Using the two locking knobs fitted to the floor tool secure the floor tool to the floor tool carrier Fig 5 Fill the clear water tank to Max of 18 litres Slide the battery into the battery compartment Fig 6 Close the flexible lid making sure it is sealed correctly Fig 7 PLEASE READ BEFORE COMMENCINGANY OPERATION AFTER THE REMOVA...

Страница 6: ... The brush is simply pushed and twisted to lock making fitting and removal a simple process Slide the brush pad under the brush deck Fit the brush pad onto the Nulock drive chuck twist to lock the brush pad in place Safety gloves are recommended for the changing of used brushes Turn on the clean water tap Fitting the Brush Pad Turn on water Fitting the Floor tool The floor tool has been designed f...

Страница 7: ...8 litre clean water tank allowing large areas to be cleaned in a single fill Filling the Clean Water Tank Fill Level Indicator Water Flow Adjustment To fill the clean water tank remove the filler cap Fig 1 Fill using a hose or a suitable container Fig 2 Use the fill indicator Fig 3 1 2 3 Fill Indicator A 1 2 B Showing the clean water tank full Fig B Showing the clean water tank empty Fig A Located...

Страница 8: ... can be adjusted with or without the brush running First pull one of the triggers then press the vacuum and water buttons to set the desired operation These states will be stored for use when the machine is restarted When the Triggers are released the brush motor and the cleaning solution pump will switch off the vacuum motor will continue for 10 seconds To Enable Disable Vacuum press button D Not...

Страница 9: ...rstood To operate set water flow rate tap lower the floor tool press the vacuum water switches pull trigger s The waste water is then retrieved by the suction floor tool Overlap each scrubbing path by 10cm to ensure an even clean Do not operate the machine on slopes that exceed 2 when full On heavily soiled floors use a double scrub technique First pre scrub the floor with the floor tool in the ra...

Страница 10: ...ter use empty waste water tank using emptying hose and flush out with clean water fig A The clean water tank can be drained via the red cap fitted to the left hand side of the machine There is a sealing bung beneath the red cap ensure the sealing bung is clean The cap should only be done up by hand fig B Emptying Top Tank Separator Emptying Bottom Tank A 1 2 3 6 5 4 B Remove the filter and basket ...

Страница 11: ...ter knobs Ensure the slotted blade goes to the front of the floor tool Note The blades are designed to be reversible thus extending their useful working life Refit the floor tool using the two central knobs to the floor tool A 1 2 3 B Replace the Squeegee blades using 903531 replacement blade set Fig 3 fitting the blades on to the moulded location lugs Remove the blade holder Fig 2 Unscrew the fou...

Страница 12: ...11 www numatic co uk Lifting the Machine Lift Points 2 Person Machine Dry Weight 34 kg Front Back Fold handle and lock in to position ...

Страница 13: ...page 4 Vacuum not operating Vacuum not turned on If vacuum light on but no vacuum operation Turn on vacuum page 7 Contact service agent Poor water pick up Waste water tank full Clogged blocked vacuum hose Loose hose connections Debris basket filter clogged blocked Separator filter clogged blocked Poor separator seal Damaged separator seal Damaged split vacuum hose Damaged floor tool blades Empty w...

Страница 14: ... manner Ear Protection Safety Footwear Head Protection Safety Gloves Dust Allergens Protection Eye Protection Protective Clothing Hi Vis Jacket Caution Wet Floor Sign PPE Personal protective equipment that may be required for certain operations NOTE A risk assessment should be conducted to determine which PPE should be worn Rating Label 1 Company Name Address 2 Machine Description 3 Voltage Freque...

Страница 15: ...or other liquids are used read the manufacturer s instructions Operators shall be adequately instructed as to the correct use of the machine For battery and charger details please refer to your battery and charger original instructions This machine is not suitable for picking up hazardous dust This machine is not to be stored outdoors in wet conditions This machine is for indoor use only NOTES Thi...

Страница 16: ...3997 DUMP HOSE ASSEMBLY 901880 PROTECTION PLUG 208471 CONSTANT TENSION CLIP DUMP HOSE 303961 TANK FILTER ASSEMBLY 903325 32MM HOSE CAP RED 905628 1840 SERVICE BUNG SEALING KIT Spare Parts Schematic Diagram Daily Keep the machine clean Ensure brushes pads squeegee filters are in good condition Check for any worn or damaged parts and replace immediately Drain and rinse dirty water tank after every u...

Страница 17: ...16 T 01460 68600 EU Declaration of Conformity ...

Страница 18: ...17 www numatic co uk Warranty ...

Страница 19: ...18 T 01460 68600 Notes ...

Страница 20: ...matic International GmbH Fränkische Straße 15 19 D 30455 Hannover DEUTSCHLAND Tel 05 11 98 42 16 0 www numatic de Numatic International SAS 13 17 rue du Valengelier 77500 CHELLES FRANCE Tel 01 64 72 61 61 www numatic fr BeNeLux Distribution Numatic International BV Postbus 101 2400 AC Alphen aan den Rijn NEDERLAND Tel 0172 467 999 www numatic nl Numatic International Pty Ltd 16th Pharmaceutical Ro...