Information for DRY USE Vacuum Cleaners

Ensure you read the instruction manual before using the machine.

Operators shall be adequately instructed on the use of these machines, as with all electrical equipment, care and attention must be exercised 

at all times during use, you must also make certain that routine and preventative maintenance is carried out periodically to ensure safe 

operation.

 

Failure to carry out maintenance as necessary, including the replacement of parts to the correct standard could render this equipment unsafe 

and the manufacturer can accept no responsibility in this respect.

This machine is for DRY USE only 

You must disconnected the machine from the mains by removing the plug from the supply socket BEFORE cleaning or maintenance and when 

replacing parts or converting the machine to another function. 

This appliance is intended to be assembled, cleaned and maintained by an adult.

This machine is not suitable for the collection of biological hazards, hazardous or explosive dusts. 

Contact your local distributor if you require a machine capable of performing these tasks.

The machine must not to be used by persons with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, 

unless they have been given supervision or instruction.

You must not allow the supply cord to come into contact with rotating brushes (if fitted).

Only use the socket outlet on the machine for purposes specified in the instructions (where fitted).

This machine is not a toy; children shall not play with this machine.

This machine must not be stored outside, or used in wet environments, or to collect wet materials. The vacuum cleaner should be stored in a 

dry place and is for indoor use only.

You must ensure that the filtration system fitted to the machine is suitable for the material being collected.

This product complies with the requirements of IEC 60335-2.69.

This machine is suitable for commercial use, for example in hotels, schools, hospitals, 

factories, shops and offices for other than normal housekeeping purposes.

If the vacuum cleaner stops working, remove the plug from the wall before investigating where the fault lies.

If the vacuum cleaner has a blockage, switch off, remove the plug from the socket outlet, and inspect the floor tool, wands and hose for debris. 

If the floor tool, wands and hose are clear, replace the dust bag and clean the filter.

The vacuum cleaner should be inspected after use for damage.

Warning

Caution

Notes

•  Keep your machine clean.

•  Keep filters clean.

•  Use filter bags, they will enhance performance and help keep machine clean.

•  Use a Numatic Original filter bag under fine dust conditions.

•  Keep hoses and tubes clear.

•  Replace any worn or damaged parts immediately.

•  Regularly examine the power cord. If damage is found such as cracking or ageing the power cord must be replaced by a qualified person 

using the correct Numatic original part.

•  Change dust bag frequently.

•  Keep diffuser filter (where fitted) clean.

•  Only use the brushes provided with the machine.  The use of other brushes may impair safety.

•  Unreel the cable with one pull or pull on the cable to unplug the machine from the power supply.

•  Use to suck up hot ashes, lighted cigarette ends or flammable gases.

•  Use steam cleaners, pressure washers or immerse in water to clean the machine.

•  Attempt machine maintenance or cleaning unless the power supply plug has been removed from the supply outlet.

•  Use in a wet environment or to collect wet materials.

•  Store your machine in wet conditions.

Do

Don’t

Содержание PSP 180A

Страница 1: ...s Lesen Sie vor Gebrauch der Maschine das Handbuch Attention Lisez la notice avant d utiliser la machine Waarschuwing Lees deze instructies voor u de machine gebruikt Owner Instructions Bedienerhandbu...

Страница 2: ...601101 601024 601024 601025 601142 601144 601529 PSP 180 PSP 200 PSP 370 NuCable 1 2 3 4 601145 601146 Kit AA1 607444 601141...

Страница 3: ...1 2 3 4 5 6 8 7 Using the Machine Arbeiten mit der Maschine Utilisation de la machine De machine gebruiken...

Страница 4: ...9 10 11 12 Hi Power Option Start Hi Light...

Страница 5: ...Cleaning the Machine Reinigung der Maschine Nettoyage de la machine De machine reinigen 15 17 13 14 16 19 1 2 2 1 18...

Страница 6: ...Removing the Face Fitting the Face on 1 2 2 1 CLICK CLICK CLICK...

Страница 7: ...601059 237373 Wand docking 2 1 3 2 4 1 Machine pictured is for demonstration purposes...

Страница 8: ...on 1200W 1200W 1200W 42 l sec 42 l sec 42 l sec Hi 2500mm w g Lo 1500mm w g Size Range Capacity Size Weight 180A 200A 370A 8L 9L 15L 340x340x350 mm 355x355x430 mm 355x355x480 mm 5 9Kg 6 1Kg 6 4Kg Clea...

Страница 9: ...cleaner should be stored in a dry place and is for indoor use only You must ensure that the filtration system fitted to the machine is suitable for the material being collected This product complies w...

Страница 10: ...l sec 42 l sec Hi 2500mm w g Lo 1500mm w g Beh lterinhalt Abmessungen Gewicht 180A 200A 370A 8L 9L 15L 340x340x350 mm 355x355x430 mm 355x355x480 mm 5 9Kg 6 1Kg 6 4Kg Reinigungsbereich Schalldruck Schu...

Страница 11: ...eignet ist Dieses Produkt entspricht den Anforderungen von IEC 60335 2 69 Neben der Verwendung in privaten Haushalten ist diese Maschine f r den gewerblichen Einsatz beispielsweise in Hotels Schulen K...

Страница 12: ...sec 42 l sec 42 l sec Hi 2500mm w g Lo 1500mm w g Capacit Dimensions Poids 180A 200A 370A 8L 9L 15L 340x340x350 mm 355x355x430 mm 355x355x480 mm 5 9Kg 6 1Kg 6 4Kg gamme de lavage Niveau sonore Classe...

Страница 13: ...ueuses ou liquides L aspirateur poussi res est destine un usage et un entreposage int rieur uniquement Assurez vous que le syst me de filtration soit appropri pour la collecte de la poussi re aspir e...

Страница 14: ...00W 42 l sec 42 l sec 42 l sec Hi 2500mm w g Lo 1500mm w g Capaciteit Afmeting Gewicht 180A 200A 370A 8L 9L 15L 340x340x350 mm 355x355x430 mm 355x355x480 mm 5 9Kg 6 1Kg 6 4Kg Bereik Geluidsniveau Besc...

Страница 15: ...tersysteem van het apparaat geschikt is voor het op te zuigen materiaal Dit product voldoet aan de eisen van IEC 60335 2 69 Deze machine is tevens geschikt voor commercieel gebruik bijvoorbeeld voor w...

Страница 16: ...A 558014 V16 Head UK 558028 V30 Head European 558055 V53 Head Swiss 500837 180 Blue Drum 500890 200 Blue Drum 500823 370 Blue Drum 236009 UK Cable 236013 European Cable 236017 Swiss Cable 604165 Filte...

Страница 17: ...nical Manager Name Allyn Boyes Manufactured by Numatic International Limited Machinery Directive 2006 42 EC EMC Directive 2004 108 EC RoHS Directive 2011 65 EU DECLARATION DE CONFORMITE EUROPEENNE Nou...

Страница 18: ...Schematic Schaltplan Sch ma lectrique Bedradingsschema DRW 4550 06 10 2010 A03...

Страница 19: ...Notes...

Страница 20: ...e Numatic International S A 13 17 rue du Valengelier EAE la Tuilerie 77500 Chelles FRANCE Tel 01 64 72 61 61 Fax 01 64 72 61 62 www numatic fr BeNeLux Distribution Numatic International BV Postbus 101...

Отзывы: