Numatic NQ.100 Скачать руководство пользователя страница 18

18

Important Warnings – Batteries

Read all the warnings before using the battery.

This cleaner uses Numatic Lithium-Ion batteries. Used batteries should be disposed of safely and placed 

in a sealed plastic bag and then handled according to all locally approved precautions and environmental 

regulations.

a) 

Do not dismantle, open or shred batteries. 

b) 

Do not expose batteries to heat or fi re. Avoid storage in direct sunlight.

c) 

Do not short-circuit a battery. Do not store batteries haphazardly in a box or drawer where they  

 

may short-circuit each other or be short circuited by other metal objects.

d) 

Do not remove a battery from its original packaging until required for use.

e) 

Do not subject batteries to mechanical shock.

f) 

In the event of battery leaking, do not allow the liquid to come in contact with the skin or eyes and  

 

avoid inhaling fumes. If contact has been made, wash the aff ected area with copious amounts of  

 

water and seek medical advice. 

g) 

Do not use any charger other than that specifi cally provided for use with the appliance. 

h) 

Do not use any battery which is not designed for use with the appliance.

i) 

Use only original NUMATIC batteries, when replacement batteries are required.

j) 

Keep batteries clean and dry. 

k) 

Do not leave a battery on prolonged charge when not in use.

l) 

After extended periods of storage, it may be necessary to charge and discharge the batteries  

 

several times to obtain maximum performance.

m) 

Retain the original appliance literature for future reference.

n) 

When possible, remove the battery from the equipment when not in use.

o) 

Do not immerse in any liquid.

p) 

Do not charge damaged batteries.

q) 

If the batteries are leaking, return batteries to a disposal plant or a similar local facility.

r) 

The batteries must be removed from the appliance before the appliance is scrapped.

s) 

If the appliance is to be stored unused for a long period, the batteries should be removed.

The battery is equipped with electronic thermal protection, refer to the 

Temperature and Humidity Range 

Table

 below for recommended operating conditions.

Temperature and Humidity Range Table

Storing

+5 ... +35 

0

C

Discharge

+5 ... +35 

0

C

Charge

+5 ... +35 

0

C

Shipment

-20 ... +60 

0

C

Humidity

25 - 85% RH no condensation

Long term storage

Humidity

≤ 50% RH no condensation

In case battery is subject to environmental conditions outside the above parameters user must allow at least 

3 hours for battery to acclimatise at room temperature before attempting to operate.

If the battery is found to be faulty at any time, contact Numatic International, 

or World Wide Lithium-Ion Battery Technical He1-703-741-5970

Содержание NQ.100

Страница 1: ...CAUTION Read instructions before using the machine KEEP FOR FUTURE REFERENCE Original Instructions numatic com NQ 100...

Страница 2: ...age 7 10 4 Filter Pod Tank Page 8 5 Hose Page 11 6 Brush release button Page 12 7 Brush release panel Page 12 8 Scent capsule cover Page 6 9 Control Panel Page 5 10 10 Lid release Pod Eject Page 8 11...

Страница 3: ...3 Box Contents Main Assembly...

Страница 4: ...4 Accessory Fitting Battery Fitting...

Страница 5: ...5 Battery Removal 2 1 3 4 5 1 Power on off 2 Battery life Charge status 3 Boost mode on off 4 Brush roll on off 5 Filter POD full system blockage Control Panel...

Страница 6: ...6 Scent Capsule Fitting Floor Tool Air Bleed Control...

Страница 7: ...Mounting Accessory Storage Use correct fixings for your wall type which is suitable for the weight of the machine 3 2kg The use of adhesives is not considered a reliable means of fixing Routing the c...

Страница 8: ...8 Disposable Pod Fitting Disposable Pod Emptying...

Страница 9: ...9 Extension Handle Fitting Removal 1 3 2 4...

Страница 10: ...10 Machine Charging Recharge time 150 mins 100...

Страница 11: ...11 Floortool Hose Cleaning Blockage Removal 1 3 5 6 2 4 7...

Страница 12: ...00 25 2 V Class III 3 2 kg 77 dB A 0 5 dB 70 min Low Brush OFF 55 min Low Brush ON 16 min High Brush OFF 14 min High Brush ON Pod Capacity Charging Times Rated Power Hand Arm Vibration Dimensions L x...

Страница 13: ...age 5 Switch the machine from boost to normal mode page 5 4 Vacuum lifts area rugs The vacuum suction may be too high and or the brush roll is picking up the rug Switch the machine from boost to norma...

Страница 14: ...7 Manufacturer 2 7 3 4 5 1 Model 2 Weight 3 Voltage Direct Current Rated Power 4 Approval Marks 5 Manufacturer 1 2 3 4 1 Model 2 Machine yr wk Serial Number 3 Weight 4 Approval Marks 5 Voltage Direct...

Страница 15: ...including hoses and tubes Ensure the filter pod is fitted Regularly examine the charger Check filter pod frequently and renew if required Weekly as daily and Check for any worn or damaged parts and r...

Страница 16: ...tairs Children should be supervised to ensure that they do not play with the appliance This machine is not a toy children shall not play with this machine Caution This machine must not be stored outsi...

Страница 17: ...nplug grasp the charger not the cord Do not cover the charger whilst charging Do not open the charger Repairs shall be done only by authorised personnel Warning The battery included in this product mu...

Страница 18: ...Keep batteries clean and dry k Do not leave a battery on prolonged charge when not in use l After extended periods of storage it may be necessary to charge and discharge the batteries several times t...

Страница 19: ...at a customer base a suspected defective battery shows any signs of impact damage distortion blistering loose parts or leakage then on no account should it be offered for condition checking It must be...

Страница 20: ...37167 A00 00 Replacement parts Spares and Accessories 914745 Numatic Battery Pack Assembly 25 2 V Graphite 915242 Battery Charger UK Plug 914746 Numatic Floor Tool Graphite 914592 Pack of 10 Pods 914...

Страница 21: ...that this may be processed without delay D Any warranty claim can only relate to the specific part that is proven to be at fault and for which a replacement will be supplied but cannot be extended to...

Страница 22: ...22 Notes...

Страница 23: ...ropria responsabilit che il prodotto di cui sopra conforme alle seguenti direttive e norme LT Mes Numatic parei kiu viena ali kos atsakomyb s kad pirmiau min tas produktas atitinka ias direktyvas ir s...

Страница 24: ...Numatic International SAS 13 17 rue du Valengelier EAE La Tuilerie 77500 CHELLES FRANCE Tel 01 64 72 61 61 www numatic fr Numatic International BV Vennootsweg 15 2404 CG Alphen aan den Rijn Nederland...

Отзывы: