Information for dry use vacuum cleaners

Warning!

Ensure you read the instruction manual before using the machine.

Operators shall be adequately instructed on the use of these machines, as with all electrical equipment, care 

and attention must be exercised at all times during use, you must also make certain that routine and preventative 

maintenance is carried out periodically to ensure safe operation.

Failure to carry out maintenance as necessary, including the replacement of parts to the correct standard could render 

this equipment unsafe and the manufacturer can accept no responsibility in this respect.

This machine is for DRY USE only 

You must disconnect the machine from the mains by removing the plug from the supply socket BEFORE cleaning or 

maintenance and when replacing parts or converting the machine to another function. 

This appliance is intended to be assembled, cleaned and maintained by an adult.

This machine is not suitable for the collection of biological hazards, hazardous or explosive dusts. Contact your local 

distributor if you require a machine capable of performing these tasks.

This machine is not a toy; children shall not play with this machine.

This machine is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of 

experience or knowledge.

You must not allow the supply cord to come into contact with rotating brushes (if fitted).

Caution

This machine must not be stored outside, or used in wet environments, or to collect wet materials. 

The vacuum cleaner should be stored in a dry place and is for indoor use only.

You must ensure that the filtration system fitted to the machine is suitable for the material being collected.

Notes

This product complies with the requirements of clause 20 of IEC/EN 60335-2-69 Stability and Mechanical Hazards.

The primary use for this machine is commercial, for example in hotels, schools, hospitals, factories, shops and offices.

If the vacuum cleaner stops working, remove the plug from the wall before investigating where the fault lies.

If the vacuum cleaner has a blockage, switch off, remove the plug from the socket outlet, and inspect the floor tool, 

wands and hose for debris. If the floor tool, wands and hose are clear, replace the dust bag and clean the filter (907073 

TriTex Filter).

The vacuum cleaner should be inspected after use for damage.

The power light will illuminate, when your machine is connected to a suitable power supply (where fitted).

Do

• 

Keep your machine clean.

• 

Keep filters clean.

• 

Use filter bags, they will enhance performance and help keep machine clean.

• 

Use a Numatic original filter bag under fine dust conditions.

• 

Keep hoses and tubes clear.

• 

Replace any worn or damaged parts immediately.

• 

Regularly examine the power cord. If damage is found such as cracking or ageing the power cord must be 

replaced by a competent person using the correct Numatic original part.

• 

Change dust bag frequently.

• 

Keep diffuser filter (where fitted) clean.

• 

Only use the brushes provided with the machine. The use of other brushes may impair safety.

Don’t

• 

Unreel the cable with one pull or pull on the cable to unplug the machine from the power supply.

• 

Use to suck up hot ashes or lighted cigarette ends.

• 

Use steam cleaners, pressure washers or immerse in water to clean the machine.

• 

Attempt machine maintenance or cleaning unless the power supply plug has been removed from the supply 

outlet.

• 

Use in a wet environment or to collect wet materials.

• 

Store your machine in wet conditions.

• 

Under any circumstances place foreign objects including (but not limited to) air fresheners, air freshener capsules 

or scented beads of any type into the top filter of the machine. Doing so can be dangerous and risk damage to 

the machine and may invalidate the machine warranty.

Allergy UK considers that HVA 160-11 (Henry) may, in proper use, reduce exposure to house dust mite allergen and cat 

allergen.

Assessments carried out by Allergy UK indicate that an individual’s exposure can be reduced but this does not mean that 

an individual’s allergic symptoms will necessarily diminish. 

Allergy UK’s opinion applies to HVA 160–11 (Henry) and the allergens stated.  

The product should only be used for its intended purpose and in accordance with the manufacturer’s instruction at all 

times. 

Allergy Information

Содержание Henry Allergy

Страница 1: ...Owner Instructions Owner Instructions CAUTION CAUTION Read instructions before using the machine Read instructions before using the machine www myhenry co uk ...

Страница 2: ...Kit AS 9 Assembly 1 2 3 4 5 6 ...

Страница 3: ...Using your machine Start Start Power Power on light on light 1 2 Low Low Low Low High High ...

Страница 4: ...1 2 Cleaning the machine 1 2 3 4 5 6 7 8 9 10 907073 Tritex Filter ...

Страница 5: ...Changing the filter 1 2 1 2 907044 H13 Filter CLICK ...

Страница 6: ...Wand docking Tool tidy 1 2 Fitting the face CLICK CLICK 1 2 ...

Страница 7: ...collected and sent for recovery in an environmentally friendly manner Safety Critical Components Mains leads HO5 V2V2 F 10 m x 2 Core x 0 75 mm2 Failure to rectify the problem or in the event of a breakdown contact your Numatic dealer or the Numatic Technical helpline 44 0 1460 269268 Daily Keep the machine clean including hoses and tubes Ensure the bag and filter are fitted Regularly examine the ...

Страница 8: ...t lies If the vacuum cleaner has a blockage switch off remove the plug from the socket outlet and inspect the floor tool wands and hose for debris If the floor tool wands and hose are clear replace the dust bag and clean the filter 907073 TriTex Filter The vacuum cleaner should be inspected after use for damage The power light will illuminate when your machine is connected to a suitable power supp...

Страница 9: ...lines including dermatology ENT surgery respiratory medicine paediatrics ophthalmology immunology and gastroenterology Allergy UK is a patient information service continuously striving to help sufferers to help themselves often seeking ways to avoid or reduce exposure to the allergens affecting them The Seal of Approval endorsement forms a part of this initiative TriTex Filter 907073 Henry Allergy...

Страница 10: ......

Страница 11: ...Warranty ...

Страница 12: ...ed Numatic International Limited Chard Somerset TA20 2GB Telephone 01460 68600 Fax 01460 68458 UNITED KINGDOM www numatic co uk GERMANY www numatic de SWITZERLAND www numatic ch FRANCE www numatic fr NETHERLANDS www numatic nl SOUTH AFRICA www numatic co za PORTUGAL www numatic pt SPAIN www numatic es Distributed by ...

Отзывы: