Numark PRO SMX NMS1 Скачать руководство пользователя страница 4

Confidential 

 

Numark Service Manual

 

Safety Instructions 

 

Carefully read the applicable items of the operating instructions and these safety suggestions 
before using this product. Use extra care to follow the warnings written on the product itself and in 
the operating instructions. Keep the operating instructions and safety suggestions for reference in 
the future.   
 
1. Power 

Source. The product should only be connected to a power supply which is described 

either in the operating instructions or in markings on the product. 

 
2. Power 

Cord 

Protection. AC power supply cords should be placed such that no one is likely to 

step on the cords and such that nothing will be placed on or against them. 

 
3.  Periods of Non-use.  If the product is not used for any significant period of time, the product's 

AC power supply cord should be unplugged from the AC outlet. 

 
4.  Foreign Objects and Liquids.  Take care not to allow liquids to spill or objects to fall into any 

openings of the product. 

 
5.  Water or Moisture.  The product should not be used near any water or in moisture. 
 
6. Heat.  Do not place the product near heat sources such as stoves, heat registers, radiators or 

other heat producing equipment. 

 
7. Ventilation.  When installing the product, make sure that the product has adequate 

ventilation. Improperly ventilating the product may cause overheating, which may damage the 
product. 

 
8. Mounting.  The product should only be used with a rack which the manufacturer 

recommends.  The combination of the product and rack should be moved carefully.  Quick 
movements, excessive force or uneven surfaces may overturn the combination which may 
damage the product and rack combination. 

 
9. Cleaning.  The product should only be cleaned as the manufacturer recommends. 
 
10. Service.  The user should only attempt the limited service or upkeep specifically described in 

the operating instructions for the user.  For any other service required, the product should be 
taken to an authorized service center as described in the operating instructions. 

 
11. Damage to the Product.  Qualified service personnel should service the unit in certain 

situations including without limitation when: 

a.  Liquid has spilled or objects have fallen into the product, 
b.  The product is exposed to water or excessive moisture, 
c.  The AC power supply plug or cord is damaged, 
d.  The product shows an inappropriate change in performance or does not operate 

normally, or 

e.  The enclosure of the product has been damaged. 

 
 
 
 
 
 
 
 
 

All manuals and user guides at all-guides.com

Содержание PRO SMX NMS1

Страница 1: ...iew dissemination distribution or duplication of this document is strictly prohibited If you are not authorized please contact Numark and destroy all copies of this document You may contact Numark at support numark com Copyright Numark Industries ATTENTION THIS DOCUMENT CONTAINS SENSITIVE PROPRIETARY INFORMATION ALL RECIPIENTS MUST HAVE A CURRENT NON DISCLOSURE AGREEMENT ON FILE WITH NUMARK INDUST...

Страница 2: ...y your responsibility and Numark shall have no liability for any such repairs or service work All such service or repairs are performed at the sole risk of the person performing the service or repairs You agree that all such work will be performed in a competent professional and safe manner at all times and to indemnify and fully hold Numark and its successors and assigns harmless in the event of ...

Страница 3: ...RIBUTOR OR AUTHORIZED REPAIR SERVICE CENTER IN THE PROVISION OF REPAIR SERVICES OR TO BE OR MAKE REPAIRS AS AN AUTHORIZED SERVICE CENTER ALL REPAIRS DONE BY ANY ENTITY OTHER THAN AN AUTHORIZED NUMARK SERVICE CENTER SHALL BE SOLELY THE RESPONSIBILITY OF THAT ENTITY AND NUMARK SHALL HAVE NO LIABILITY TO THAT ENTITY OR TO ANY OTHER PARTY FOR ANY REPAIRS BY THAT ENTITY Regarding the Power Supply Fuse ...

Страница 4: ...tors or other heat producing equipment 7 Ventilation When installing the product make sure that the product has adequate ventilation Improperly ventilating the product may cause overheating which may damage the product 8 Mounting The product should only be used with a rack which the manufacturer recommends The combination of the product and rack should be moved carefully Quick movements excessive ...

Страница 5: ...J0614G 4 2 E JK 082 00 RCA JACK 2P CPS0326GH 92 鍍金 1 E VR 242 00 VR RK45K1F 10 15C1 0B50K 2 E VR 244 00 VR RA2063F 20 15C1 B100K 1 E VR 245 00 VR RA2062F 20 15C1 B50K C C 2 E SW 059 00 LEVER SW LBC23M 095 2 E SW 133 00 SW SLW 22 12KB 1 E VR 247 01 SMT SVR TSR C3305 200KB 2 E VR 247 02 SVR TSR 66 5 5 200K 2 E JK 044 00 H P JACK LJE0664 6 1 E SW 077 00 SLIDE SW SS 22F39 G5 2 E SW 102 01 SW MR 21N 4B...

Страница 6: ... 4 012 13 05 6 8P 5P 30 AC DC 29 PH 28 OSC 19 A GND 24 NC 20 DC IN 23 CR2 22 CH2 IN 21 CH1 IN 26 MUTE 27 CR1 25 NC 15 D1 16 IC114 LB1482M LD303 GRN LD304 GRN LD305 GRN LD306 GRN LD307 GRN LD302 GRN LD309 GRN LD310 GRN LD311 RED LD312 RED LD313 RED LD308 GRN LD103 GRN LD104 GRN LD105 GRN LD106 GRN LD107 GRN LD102 GRN LD109 GRN LD110 GRN LD111 RED LD112 RED LD113 RED LD108 GRN R243 220 R244 220 R245...

Страница 7: ...All manuals and user guides at all guides com ...

Страница 8: ...All manuals and user guides at all guides com ...

Страница 9: ...All manuals and user guides at all guides com ...

Отзывы: