EZ-IN
®
Series
BF Turbine Flowmeter Manual
6
Calibration
The EZ-IN
®
Series BF Turbine Flowmeter is precalibrated with water at
the factory and tagged with the calibration factor in pulses/gal. For
maximum accuracy with fluids other than water, calibrate the meter with
the actual fluid being measured in the flowline. This meter can be proved
by any of the conventional methods used to prove other turbine meters.
Maintenance and Repairs
If the flowmeter is exposed to abrasive fluids or long periods of over-
range flow rates, periodically check it for possible wear.
Removing and Inspecting the Meter
1.
Remove the magnetic pickup (Fig. 3, Page 7) to avoid damaging it.
2.
Remove one or more of the flange bolts (Fig. 3, Page 7). Loosen the
remaining flange bolt nuts to allow clearance for the meter. Free the
meter by turning the spreader nuts.