I N S T R U C T I O N

M A N U A L

NUCLEONIX SYSTEMS PRIVATE LIMITED

Plot No. : 162 A&B, PHASE II, I.D.A. Cherlapally, Hyderabad - 500 051.

Ph : 040-27263701, 32914548, Fax : 040-27262146

e-mail : [email protected]  website : www.nucleonix.com

File Name

:

RM704_Man

Date

:

12-05-2014

GAMMA RADIOGRAPHY SURVEY METER

TYPE : RM704

Содержание RM704

Страница 1: ...S PRIVATE LIMITED Plot No 162 A B PHASE II I D A Cherlapally Hyderabad 500 051 Ph 040 27263701 32914548 Fax 040 27262146 e mail info nucleonix com website www nucleonix com File Name RM704_Man Date 12...

Страница 2: ...MENT MAINTENANCE SERVICES 10 15 AND WARRANTY CLAUSE Important Note For all Radiation meters which are battery powered exported battery cells are removed shipped This is because air line customs will n...

Страница 3: ...hr in 5 linear ranges It also measures count rate in the range of 0 99999 cps in 4 linear ranges It has a lot of unique features which includes user interface through a set of four commands buttons th...

Страница 4: ...isplay Energy response Within 20 in the range of 60 KeV to 1 33 MeV Time constant Floating time constant of 4 sec 8 sec Preset alarm range 0 999 9 mR hr or 0 9999 mSv hr or 0 9999 cps Once dose rate c...

Страница 5: ...io status to either ON headphone mode or ON Buzzer mode or OFF 0 20 40 1 0 0 80 60 10 30 50 70 90 NUCLEONIX Now using p or q buttons select the required unit as R hr or Sv hr or CPS After last key pre...

Страница 6: ...in cps unit 3 2 MEASUREMENT MODE RANGE SELECTION 3 2 1 R hr MODE The unit operates in 5 linear ranges 0 5mR hr 0 50mR hr 0 500mR hr 0 5R hr and 0 50R hr Depending upon the doserate countrate the rang...

Страница 7: ...mSv hr X5mSv hr 3 2 3 CPS MODE The unit operates in 4 linear ranges 0 100cps 0 1000 cps 0 10000 cps and 0 99999 cps Depending upon current doserate the range of operation is selected automatically The...

Страница 8: ...eds full scale of the instrument O Fl is shown on the instrument Step 2 Dose rate count rate inter pretation For a given measurement range unit the doserate countrate canbe measured by using 2 methods...

Страница 9: ...sion 80 Additionally 3 minor segments following 80 are also lit The Multiplication factor shown is X 0 5mSv hr Now the doserate 80 3x2 x 0 5mSv hr 4 30mSv hr 0 20 40 1 0 0 80 60 10 30 50 70 90 mR hr N...

Страница 10: ...or E2 PROM Reset circuit and buzzer driver ckt The display user input interface section comprises of a custom LCD display a 2x2 matrix keypad for configuring and use of the instrument the custom LCD c...

Страница 11: ...M OF GAMMA RADIOGRAPHY SURVEY METER RM704 Keypad 2x2 LCD display custom for analog scale indication direct digital readout MCU E2 PROM RESET Chip BCD counter 500V Buzzer driver ckt ve tail to TTLconve...

Страница 12: ...during warrantee after the customer receives approval from the customer support division by sending an e mail For all equipments costing less than 6 0 lakhs one year warrantee free service is offered...

Страница 13: ...des Engineer s TA DA etc apart from basic service charges cost of spares etc Please note that basic service charges will be different for different products depending upon sophistication Also in some...

Страница 14: ...following mode of transportation system for dispatching on door delivery basis XPS GATI cargo Courier RPP Speed Post parcel etc Send the equipment on freight paid basis Equipments sent by other metho...

Страница 15: ...division CSD by giving required inputs Inputs required by our CSD to send you AMC proposal Name year data of purchase Sl Nos of equipments Model No s No of equipments for which AMC is required Additi...

Страница 16: ...he battery holder are to be removed and replaced with new set of batteries ensuring proper polarity Step 4 5 d Now check battery voltage again for that switch ON the unit and see that LB is not displa...

Страница 17: ...15 N U C LEO N IX SYSTEM S PVT LTD Step 2 Step 3 Step 4 Step 5...

Отзывы: