nubeca RT-1241 Скачать руководство пользователя страница 16

17

Step 2 Press the Mode button 

for 5 seconds to enter the dis-

play mode to select Room mode.

The Room temperature indicator “ 

 ” 

Step 4  Read the result.

Release the button and read the result. “ 

 ” is shown together with a temperature 

value and two short beeps.

Step 3  Press and hold the On/Scan button.

The built-in sensor inside the thermometer will capture the ambient 

temperature automatically. 

Содержание RT-1241

Страница 1: ...OWNER S MANUALR RT 1241 Infrared Forehead non contact Thermometer...

Страница 2: ...ision is necessary when the thermometer is used by on or near children handicapped persons or invalids 2 Use the thermometer only for the intended use described in this manual 3 Do not use the thermom...

Страница 3: ...S 08 DISPLAY SCREEN 08 DISPLAY MODE 09 SETTING THE THERMOMETER 10 REPLACING THE BATTERY 11 ABOUT NORMAL BODY TEMPERATURE FEVER 12 USING THE DEVICE 14 As a Body Scan Thermometer 14 As a Surface Scan Th...

Страница 4: ...e contact customer services immediately Do not touch the lens Do not disassemble the thermometer Basic safety precautions should always be observed especially when the thermometer is used on or near c...

Страница 5: ...surface Intended Use RT 1241 Thermometer is intended for the intermittent measurement and monitoring of human body temperature from forehead measure ment at home The device is intended for use by peop...

Страница 6: ...r off if left idle for 30 seconds Memory function allows you to recall previous results up to 10 previous results Easy to read LCD with backlight in a dark environment Able to measure temperature of o...

Страница 7: ...7 MEM Button 8 Battery Cover 1 Low battery indicator 2 Date indicator 3 Date Time 4 Temperature reading 5 Body temperature indicator 6 Object surface temperature indicator 7 Room temperature indicator...

Страница 8: ...s mode is used to measure the forehead temperature It also provides clock 2 Surface mode This mode is used to measure the object surface tempera ture It also provides clock 3 Room mode This mode is us...

Страница 9: ...etting mode Step 2 Set the date and time Press the Mode or C F button to select the correct month Press the to move on the next step Press the Mode or C F button to select the correct day year hour mi...

Страница 10: ...romptly see a doctor for help NOTE The thermometer comes with two 1 5 V AA alkaline batteries The meter will display to alert you when the meter power is getting low If and appear both please follow t...

Страница 11: ...t experience fever even when they are ill These include but are not limited to infants younger than 3 months old persons with compromised immune systems persons taking antibiotics steroids or antipyre...

Страница 12: ...ng the body surface room temperature C or F for your preferred selec tion SELECT THE TEMPERATURE UNIT Step 1 Press the Step 2 Press the C F button to select Press the to begin the mea surement or keep...

Страница 13: ...for 5 seconds to enter the dis play mode to select Body mode The Body temperature indicator Step 3 Move the probe close to the forehead Press and hold the Make sure the at an angle Perform a forehead...

Страница 14: ...he forehead measurement the reading will be affected by surrounding temperature The thermometer will automatically turn off if left idle for 30 seconds NOTE As a Surface Measurement Thermometer Step 1...

Страница 15: ...e and two short beeps Step 3 Move the probe close to the object surface Press and hold the Make sure the not at an angle Perform an object mea surement with a distance within 5 cm As a Room Measuremen...

Страница 16: ...The Room temperature indicator Step 4 Read the result Release the button and read the result is shown together with a temperature value and two short beeps Step 3 Press and hold the On Scan button Th...

Страница 17: ...ess the to turn on the thermometer Step 3 Press the MEM button to enter the memory mode Each time you press the MEM button a result will be displayed in the order of dates gether with and number from...

Страница 18: ...t waterproof Please wipe with a clean and dry cot ton swab to clean the probe on the inside The body of the thermometer is not water resistant Never put the thermometer under a running tap or submerge...

Страница 19: ...vi ronmental tempera ture is above system operation range Put the thermometer under operating tem perature range of 10 C to 40 C 50 F to 104 F Battery is low and appears on LCD Please replace batterie...

Страница 20: ...111 2 F Display resolution 0 1 C 0 1 F Accuracy 0 2 C 0 4 F for the range of 36 0 C to 39 0 C 96 8 F to 102 2 F 0 3 C 0 5 F for less than 36 0 C 96 8 F and greater than 39 0 C 102 2 F Temperature uni...

Страница 21: ...Symbol Referent Consult instructions for use Manufacturer Serial number Caution consult accompanying documents CE mark Type BF Equipment Do not use if package is damaged Authorized representative in t...

Страница 22: ...to the requirements of the standard for infrared thermometers ASTM E1965 98 EN 12470 5 EN 60601 1 2 2007 AC 2010 EN 60601 1 4 1996 EN 60601 1 6 2010 Electromagnetic Compatibility EN 60601 1 2 The stip...

Отзывы: