Installation Manual

Remove front grille.
Release 2 screws. Lift grille upwards.

Remove fan plate.

Prepare the wall aperture to dimensions shown. 

XS6WA  260mm sq.
XS9WA  330mm sq.
XS12WA  410mm sq.

A

A

Cut the spacer to match the walls total thickness
using a fine / medium cut woodsaw.

Fit the temporary cross brace across wall sleeve’s 
outer end to support the sides during installation.

Polystyrene
former fits
temporarily
into sleeve end.

Make hole for
supply cable 

Locate the temporary plug to support the other end.

INSIDE

OUTSIDE

Install the sleeve 
at a slight angle 
(lower to outside)

IMPORTANT !

When fitting the sleeve, introduce a slight downward slope
to the outside, to encourage any water to drain to outside.

Polystyrene former
supporting sleeve
end.

 

Supply wire 
inside sleeve

Make good around 
the wall sleeve.

Make good 
the inside and 
outside walls 
flush with the 
sleeve.

Temporary
crossbrace

 

3.0 MECHANICAL INSTALLATION

Installation must be completed by competent persons, in accordance 
with good industry practice and should conform to all governing and 
statutory bodies i.e. IEE, CIBSE, etc.

10 

Removing Front Grille

Fitting Temporary Cross Brace

Removing Fan Plate

Fitting Polystyrene Former

Preparing Wall Aperture

Fitting Wall Sleeve

Cutting Spacer

Making Walls Good

Содержание XS12WA

Страница 1: ...by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Precautions must be taken to avoid the back flow of gases into the room from the open flue of gas or ot...

Страница 2: ...rated via the optional XS MFC remote controller allowing supply or extract variable speed and automatic or manual switching of several fans if desired 2 2 Sensors Sensors are available as remote units...

Страница 3: ...support the other end INSIDE OUTSIDE Install the sleeve at a slight angle lower to outside IMPORTANT When fitting the sleeve introduce a slight downward slope to the outside to encourage any water to...

Страница 4: ...e Assembling Fan Release the electrical cover from the fan plate Bring the cable through the fan plate Assemble the fan plate to the inside sleeve IMPORTANT During shutter operation of XS fans there w...

Страница 5: ...ed control This avoids the possibility of one fan if speed controlled at a lower flow rate being stalled by the other fan s Adequate make up air provision sufficient to provide ventilation in accordan...

Страница 6: ...5 L4 L3 L2 L1 N L4 L3 L2 L1 N L1 N Double pole isolator Fuse max 3 amp L N XS Fan unit with integral sensor Required if using integral Timer mains supply Remote switch may be set On Off Forward Revers...

Страница 7: ...ors Optional The XS MFC Multi Fan Control provides supply or extract variable speed and automatic or manual switching of several fans if desired see note below The control is best mounted approx 1 5m...

Страница 8: ...the prepared wall 37 Mounting Backplate 5 0 ANCILLARIES 5 1 Weather Terminal Used for exposed site wall installations comprising one weather terminal manufactured from HIPS Order Code XS WT6 Dimensio...

Страница 9: ...0 END OF LIFE AND RECYCLING Where possible Nuaire use components which can be largely recycled when the product reaches its end of life Fans motors controls actuators cabling and other electrical comp...

Страница 10: ...10 18 03 20 Document Number 671051 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk XS WA Installation Manual NOTES...

Страница 11: ...11 18 03 20 Document Number 671051 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk XS WA Installation Manual NOTES...

Страница 12: ...12 18 03 20 Document Number 671051 Nuaire Western Industrial Estate Caerphilly CF83 1NA nuaire co uk XS WA Installation Manual NOTES...

Отзывы: