SLIMAIRE / NA XPC
Installation Manual
IMPORTANT
Isolation - Before commencing work make sure that the
unit is electrically isolated from the mains and switched live
supply.
L
N
L
N
Double Pole Isolator
230V
~
50Hz
L
N
L
N
T
Triple Pole Isolator
230V
~
50Hz
Fan Unit
N
L
12V
N
L
230V
N
L
Transformer
Double Pole Isolator
N
L
230V
~
50Hz
L
N
T
Fan unit
L N
12V
N
L
230V
N
L
Transformer
Triple Pole Isolator
230V
~
50Hz
2
3
4
5
Wiring - SLIMAIRE/NA 100XPC/150XPC
Wiring - SLIMAIRE/NA 100XPC/150XPC
Wiring - SLIMAIRE/NA 100XPC-12
Wiring - SLIMAIRE/NA 100XPC-12
4.0 ELECTRICAL INSTALLATION
4.1 Electrical Information
Unit Codes
m³/hr
Pa
W
dBA @ 3m
NA / SLIMAIRE 100X
95
27
11
40
NA / SLIMAIRE 150X
280
320
26
49
It is recommended that the installation be carried out by a qualified
electrician. All electrical connections must comply with current IEE
wiring regulations. The fan is a fixed appliance, and the electrical supply
must therefore be by a fixed wired and fused (3 amp) spur incorporating
a double or triple pole switch with contact openings of at least 3mm.
Use twin conductor cable of at least 1mm3 in section (Figure 9).
The fan is double insulated and does not require earthing. The fan
complies with current electrical safety regulations (IE64, CENELEC
384), including EEC Directive EMC2004/108/CE concerning the
suppression of radio interference and electromagnetic compatibility,
and LVD2006/95/CE.
The fan must not be used as a switch for water heaters, stoves etc.
The printed circuit board in these fans has been protected to make it
compatible with the majority of fluorescent fittings available on the
market today. However, it is impossible to be aware of all new products
introduced. We suggest, therefore, that you contact your supplier to
establish the compatibility of any fluorescent fittings you intend to use.
4.2 Wiring diagrams
4.2.1 SLIMAIRE/NA 100XPC/150XPC with Integral Cord
4.2.2 SLIMAIRE/NA 100XPC/150XPC
4.2.3 SLIMAIRE/NA 100XPC-12 with Integral Cord
4.2.4 SLIMAIRE/NA 100HT/100PIR/150HT/150PIR with
Humidistat and Integral Sensor Only