2
Nuaire |
Western Industrial Estate
|
Caerphilly
|
CF83 1NA
|
nuaire.co.uk
28. 01. 20. Document Number 671881
Installation Manual
NOXMASTER
1.2 Personal Protective Equipment
The following minimum PPE (Personal Protective Equipment) is
recommended when interacting with Nuaire product:
•
Protective Steel Toed Shoes -
when handling heavy objects.
•
Full Finger Gloves (Marigold PU800 or equivalent) -
when
handling sheet metal components.
•
Semi Fingerless Gloves (Marigold PU3000 3DO or equivalent)
- when conducting light work on the unit requiring tactile
dexterity.
•
Safety Glasses
- when conducting any cleaning/cutting operation
or exchanging filters.
•
Reusable Half Mask Respirators
- when replacing filters which
have been in contact with normal room or environmental air.
Nuaire would always recommend a site specific risk assessment by a
competent person to determine if any additional PPE is required.
2.0 INTRODUCTION
Nuaire’s NOXMASTER range has been specifically designed to improve
the indoor air quality and provide a whole home ventilation solution.
Combining the principles of positive input ventilation (PIV) and carbon
filter technology the unit provides cleaner, fresher, filtered air into the
a dwelling at a continuous rate, encouraging the movement of air from
inside to outside. To achieve this, the unit is mounted in the loft space
and draws air from either the loft space or ducted supply from the
exterior of the house (dependant on the operating temperatures).
•
Carbon filters/pellets are not to be ingested, ensure hands are thoroughly washed after handling.
•
Precautions must be taken to avoid the back-flow of gases into the room from the open flue of
gas or other fuel-burning appliances.
•
This appliance should not be used by children or persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge, unless they have been given supervision
or instruction concerning the safe use of the appliance by a person responsible for their safety.
Children shall not play with the appliance. Cleaning and user maintenance shall not be carried
out by children.
1.1 Hazard Symbols
GENERAL WARNING
Signifies a general warning regarding hazard specified by supplementary information.
ELECTRIC SHOCK
This unit must be completely electrically isolated before any panels are removed. Check
mains supply and control connections.
ROTATING PARTS
This unit contains fast moving rotational parts which may start automatically. It is the
sole responsibility of the installer to adequately guard these components.
REFER TO INSTRUCTION MANUAL
Read and understand the installation and maintenance manual before installing,
operating or maintaining this product.
Unlike conventional PIV units, NOXMASTER units are fitted with
dual inlets, which automatically select the air source based on the
surrounding temperature:
•
If the loft temperature is below the set point (recommended 24°C)
then the unit will take fresh air from the loft space.
•
If the loft temperature is above the set point (recommended
24°C) then cooler fresh air will be taken from outside the dwelling
through a ducted supply (if fitted).
To improve the efficiency of the NOXMASTER unit, it is fitted with a
carbon filter bypass. The bypass is controlled on a time basis and is
programmed to operate during times of low pollution (e.g. night time
when air pollution is lower).
2.1 Code description:
NOXMASTER-HEAT PM2.5 P
| | | |
1 2 3 4
1. Range:
NOXMASTER
2. Heater:
No Affix
= No Heating Elements
HEAT
= 400W Heating Elements
3. Spigot Diameter (mm):
No Affix
= Single Euro Pallet Delivery
PM2.5
= 3 Individually Packaged Boxes
4. Packaging:
No Suffix
= Single Euro Pallet Delivery
P
= 3 Individually Packaged Boxes
2.2 Packaging & Delivery
The system will be delivered in 3 boxes and may be strapped to a
pallet therefore please consider handling and storage space.