28. 01. 20. Document Number  671881

NOXMASTER

PIV with Carbon Filtration 
Installation and Maintenance

EMC Directive

 

2014/30/EU

LVD Directive

 

2014/35/EU

1.0 SAFETY INFORMATION

• 

The provision of the electrical supply and the connection of the NOXMASTER unit to the mains 
must be carried out by a qualified electrician. 

• 

For installation and maintenance isolate from power supply before removing any covers. 

• 

All-pole disconnection from the mains as shown in the wiring diagram must be incorporated 
within the fixed wiring and shall have a minimum contact separation of 3mm in accordance with 
latest edition of the wiring regulations. 

• 

In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance 
must not be supplied through an external switching device, such as a timer, or connected to a 
circuit that is regularly switched on and off by the utility. 

• 

The fan unit is supplied with a fused spur. The three core mains cable from the fan unit should 
be connected to a fixed wiring installation, via the spur, in accordance with current IEE wiring 
regulations. 

• 

If the mains supply cord to the PSU is damaged, it must be replaced by the manufacturer, its 
service agent or similarly qualified persons in order to avoid a hazard. 

• 

The heater unit must be connected to the ceiling vent and fan unit using the 3 looms that 
protrude from the heater module. 

• 

The unit must be situated in a dry environment that avoids dripping water and installed fully 
level in the horizontal plane. 

• 

It is important to ensure that the diffuser is NOT placed within 1 metre of a smoke alarm. If the 
diffuser cannot be repositioned, two sides of the diffuser must be closed off using the air dams 
supplied to encourage the air through the remaining open sides that faces at least 1.5 metres of 
unobstructed area away from the smoke alarm sensor. 

• 

If the unit is required to switch off in the event of smoke/CO detection, alarms are available with 
separate relay bases from 3rd party companies. This is a mandatory requirement for all units 
installed in a 3 Storey property. 

• 

The flexible duct (maximum length 2m) is connected to the base unit by inserting the duct 
over the outlet duct and held in place using the supplied cable tie. Fix the duct in place by 
drilling through the duct into the spigot (at the 2 O'clock and 10 O'clock position) and screwing 
together. Finally secure the duct with a cable tie fitted between the screws and outlet face of the 
unit. 

• 

Ducting must be securely fixed with screws to the spigot to prevent access to live parts. 

• 

When installing the duct to the heater unit, insert the duct over the back of the heater, over 
the protruding screw heads (3mm from the face of the duct) and fasten the cable tie below the 
screws. This ensures that the duct will be held on securely, check all duct joints are air tight. 

• 

Appropriate PPE (Personal Protective Equipment) should be worn during maintenance. 
Precautions may also be needed to protect the surrounding area from excess carbon residue. 

Содержание NOXMASTER Series

Страница 1: ...module The unit must be situated in a dry environment that avoids dripping water and installed fully level in the horizontal plane It is important to ensure that the diffuser is NOT placed within 1 m...

Страница 2: ...ack of experience and knowledge unless they have been given supervision or instruction concerning the safe use of the appliance by a person responsible for their safety Children shall not play with th...

Страница 3: ...800 Delivery Option P Three Individual Boxes BOX 1 362 981 585 22 BOX 2 362 685 685 12 BOX 3 340 535 230 6 POD A Carbon Filter Weight 22Kg AIRFLOW POD B Blower Weight 12Kg 1371 463 168 PLEASE ALLOW 3...

Страница 4: ...the duct will be held on securely check all duct joints are air tight FURTHER MEASURES MAY BE REQUIRED 3 3 NOXMASTER Installation 3 3 1 Connecting Sections The unit is delivered in two sections pod A...

Страница 5: ...NOXMASTER Modules Fitting Dual Inlets Ceiling Joist Metal Mounting Bracket A V Mount A V Mount Washer 3 Woodscrew 50mm Min 12mm Clearance Hole Spigot Guard Punched out and removed 150mm inlet duct to...

Страница 6: ...s IMPORTANT Disconnection from mains must be incorporated within the fixed wiring and shall have a minimum contact separation of 3mm in accordance with latest edition of the wiring regulations NOXMAST...

Страница 7: ...orange LED is not lit the heater is off In order to enable the heater press the DOWN button for five seconds and release The orange LED will illuminate indicating that the heater is active and in aut...

Страница 8: ...ted in Pod A larger section Isolate the unit from mains power supply Unscrew the fixings securing the lid in place and remove lid from unit Figure 8 Remove the Carbon filter s by lifting vertically Re...

Отзывы: