We declare that the machine named below 

conforms to the requirements of EC Council Directives 

relating to Electromagnetic Compatibility and 

Safety of Electrical Equipment.

Designation of machinery :-

CONTINUOUS VENTILATION UNITS

Machinery Types :-

MEV-M, MEV-2M, MEV-M+

Relevant EC Council Directives :-

89/336/EEC, 92/31/EEC (EMC)
73/23/EEC, 93/68/EEC (Low Voltage Directive)

Applied Harmonised Standards :-

E50081-1, EN50082-1, EN60204-1
EN60335-2-80

Basis of Self Attestation :-

Quality Assurance to BS EN ISO 9001
BSI Registered Firm Certificate No. FM 149

Signature of manufacture representatives :-

Name:

Position:

Date:

1) 

C. Biggs

Technical Director

2. 7. 01

2)                                                         W. Glover

Manufacturing Director                2. 7. 01

NuAire Limited,
Western Industrial Estate,
Caerphilly, Mid Glamorgan,
CF83 1XH. United Kingdom.
Telephone: 029 2088 5911
Fax: 029 2088 7033
Email: info @ nuaire. co. uk 
www.nuaire.co.uk

JULY  2001

DECLARATION 
OF CONFORMITY 

Содержание MEV-M

Страница 1: ...f the case cover The fan is designed to be wired direct to the mains supply through a fused spur isolator by others and run continuously in the NORMAL mode which is the low speed or trickle ventila tion setting The degree of extract from each room served can be adjusted with the inlet balancing spigots The unit is provided with adjustment for the trickle low speed or NORMAL and high speed BOOST ve...

Страница 2: ...gots and fix to the case using the holes provided Unit fixing The fixing bracket can be offered up to position the fixing points marked through and the bracket installed with 4 screws by oth ers Offer the unit into position and locate the bracket into the slots in the case before fixing with the single bracket fixing screw See fig 3 Connect the ductwork to the inlet and outlet spigots Electrical c...

Страница 3: ...k See wiring diagram on page 4 Removing the blower s see fig 6 Assuming that the control module has been unplugged from the terminal block the external electical wiring disconnected and the complete unit removed from the installation 1 Withdraw the filter assembly from the case 2 Unscrew the two motor plate retaining screws A 3 Allow the upper edge of the plate to drop away from the fixed plenum p...

Страница 4: ...r Status Fault Earth post Fan terminal block Fan terminal block N L Fuse 2A max Unit serving Kitchen and Bathroom 230V 1ph 50Hz supply 3 1 N L 2 Room light Normal Boost switch kitchen Light switch bathroom Light switch double pole Earth post N L Fuse 2A max Unit serving Kitchen and two Bathrooms 230V 1ph 50Hz supply 3 1 N L 2 Room lights Normal Boost switch kitchen Earth post Fan terminal block N ...

Страница 5: ...w Voltage Directive Applied Harmonised Standards E50081 1 EN50082 1 EN60204 1 EN60335 2 80 Basis of Self Attestation Quality Assurance to BS EN ISO 9001 BSI Registered Firm Certificate No FM 149 Signature of manufacture representatives Name Position Date 1 C Biggs Technical Director 2 7 01 2 W Glover Manufacturing Director 2 7 01 NuAire Limited Western Industrial Estate Caerphilly Mid Glamorgan CF...

Страница 6: ...nded by the CDM regulations The remaining two years covers replacement parts only NOTE Installation Maintenance of the equipment must be as directed in the instructions provided with the unit 6 Maintenance General It is inevitable that some dust fluff etc will pass through the filter and which if allowed will build up internally on motors and impellers shortening the life of the unit and in severe...