MEV-ECO-CF
Installation Manual
4.0 ELECTRICAL INSTALLATION
All electrical connections must be carried out by a qualified electrician.
To prevent water ingress, the supply cord should be run so the lowest
point is below the cable entry grommet.
For good EMC practice, any sensor cable or switched live cables
should not be placed within 50mm of, or on, the same metal cable
tray as other cables.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
All pole disconnection from the mains as shown in the wiring
diagram, must be incorporated within the fixed wiring and shall
have a minimum contact separation of 3mm in accordance with
latest edition of the wiring regulations.
4.1 Electrical Information
Voltage:
230V 1ph 50Hz
Consumption:
0.7A
The cable from the mains power supply should be connected to a fixed
wiring installation, via a fused isolator, in accordance with current IEE
wiring regulations.
4.2 Wiring Diagrams
Only the 5 Core cable is supplied with the unit, any other
components in diagrams below are not included.
Fuse 2A
MAINS
230V
50Hz
N
L
3 Pole
isolator
Boost
Blue
Brown
Black
Optional 3rd speed switch to
activate purge set point.
Black (boost) and Grey (purge) are live connections.
If not used, terminate safely.
Supply cord
from unit
Grey
Green/yellow
5
Wiring