OPERATION GUIDELINES  

The fan is rated for connection to single‐phase AC power mains 220…240 V / 50/60 Hz. 
The fan is designed for continuous operation always connected to power supply.  
The arrow on the fan casing must match the air direction in the system.  
Ingress protection rating against access to hazardous parts and water ingress is  IPX4. 
The fan is rated for operation at the ambient temperature ranging from +1 °C up to +45 °C. 
The transported air temperature must not 60 °C. 

CONTROL LOGIC   

ILM 

XXX T starts operation as the  external  switch supplies a control signal to the LT input terminal, for instance, 

during switching the light on. After a control signal is off the fan continues operating for the set time as adjusted from 
2 to 30 min. To adjust the turn‐off time setting rotate the T time control knob clockwise to increase or 
counter‐clockwise to decrease it accordingly (Fig. 

29

).  

Warning!  
The timer circuit is under mains voltage. Disconnect the fan from power mains prior to any adjustments and operations! 
The fan delivery set includes a specially designed plastic screwdriver for fan settings adjustments. 
Use it to adjust the fan turn‐off delay time or the humidity sensor set point. Do not use a metal screwdriver, knife, etc. 
for adjustments not to damage the circuit board.  

ILM 

XXX U (U1) is equipped with the electronic TSC module (speed controller with electronic thermostat) for automatic 

speed control (air capacity regulation) depending on air temperature (Fig. 3

1

). 

The terminal compartment incorporates 2 control knobs:  
for setting the fan speed; 
for setting the thermostat set point.  

The thermostat operating LED light is located on the fan casing. It glows as air temperature exceeds the set point. 
To set the thermostat set point rotate the temperature control knob clockwise to increase or counter‐clockwise to 
decrease the temperature set point accordingly. 

7

!

WARNING

Содержание ILM 125S

Страница 1: ...USER S MANUAL INLINE MIXED FLOW FANS Nuaire ILMXXX 2017 www nuaire co uk...

Страница 2: ...ower mains must comply with the acting local electrical norms and standards The fixed electrical wiring must be equipped with an automatic circuit breaker The fan must be connected to power mains thro...

Страница 3: ...vent ingress of smoke carbon monoxide and other combustion products into the room through open chimney flues or other fire protection devices Sufficient air supply must be provided for proper combusti...

Страница 4: ...der to ensure the efficient stream Do not sit on the fan and do not put objects on it The timer circuit is live Disconnect the fan from power supply prior to any adjustment operations The fan delivery...

Страница 5: ...on or instruction regarding a safe use of the product and understand the risks involved Do not allow children play with the product Fan cleaning and maintenance must only be performed by children unde...

Страница 6: ...y timer adjustable for 2 up to 30 minutes Fig 29 ILM XXX U U1 modification with a speed controller and electronic thermostat integrated temperature sensor and power cable with a plug Fig 31 ILM XXX Un...

Страница 7: ...ounter clockwise to decrease it accordingly Fig 29 Warning The timer circuit is under mains voltage Disconnect the fan from power mains prior to any adjustments and operations The fan delivery set inc...

Страница 8: ...switches to the maximum speed As air temperature drops down below the temperature set point the timer starts 5 minutes countdown and then the fan switches to the set lower speed If the initial air te...

Страница 9: ...the temperature from 5 C up to 40 C and relative humidity below 80 The storage environment must not contain dust acid or alkali vapours that may cause corrosion of the product parts MANUFACTURER S WA...

Страница 10: ...in the user s manual including submission with missing component parts previously dismounted by the user Mismatch of the fan model and the brand name with the information stated on the fan packing and...

Страница 11: ...ssing seals if provided by the user s manual Failure to submit the user s manual with the fan purchase date stamp Missing payment document certifying the fan purchase FOLLOWING THE REGULATIONS STIPULA...

Страница 12: ...2 min 1 m 12...

Страница 13: ...5 3 6 4 MOUNTING QF 13...

Страница 14: ...9 7 8 10 14...

Страница 15: ...12 13 14 15 16 17 18 ILM 100 125 ILM 125S 150 160 MAX MIN MAX MIN MAX MIN MAX MIN N L2 N L QF X N L1 N L QF X QF N L1 L2 S N L X L2 L L1 N X N L1 N L QF X N L2 N L QF X L2 L L1 N X QF N L1 L2 S N L X...

Страница 16: ...cts N L ST QF N L LT L1 X S N L ST QF N L LT L1 X L2 N L ST QF N L LT X N L ST QF N L LT L1 X S N L ST QF N L LT L1 X N L ST QF N L LT L2 X ILM 100 T 125 T 125ST 150 T 160 T 16 terminal block for 5 co...

Страница 17: ...26 23 24 25 27 28 QF 17...

Страница 18: ...30 29 30 min 2 min MIN MAX STOP X 18...

Страница 19: ...32 31 ILM U U1 21 22 23 24 25 26 27 28 29 min max t C 30 C 20 C Temperature control knob Speed control knob min max 19 ILM Un Un1 Speed control knob...

Страница 20: ...35 33 36 34 20...

Страница 21: ...39 37 38 21...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...ILM XXX17 ILM 100 125 125S 150 160 V RV T U P 1 n ACCEPTANCE INFORMATION Fan is ready for using Acceptance stamp Date of production Sold name of trade enterprise and stamp of the shop Date of sale...

Отзывы: