147 mm

S

ide view

Plan view

View inside cover 

End view

Cover fixings

85 mm

85 mm

60 mm

Mains supply
230v 1ph 50Hz

12v supply to fan

N   L  SL  

N   L  SL  

12V

12V fan units must be installed in accordance with 

these instructions and IEE Wiring Regulations BS7671 

for SELV installations.

4

11. 05. 17. Leaflet Number 671182

Installation and Maintenance

GENIE 12V & 230V Universal Surface Mounted Fans

Installation of Transformer
Enclosure (12 Volt units only)

The enclosure containing the transformer is 
intended to be mounted out of sight (e.g. in a loft, 
cupboard, under floorboards etc.). However, if this 
is not possible the transformer enclosure should be
mounted as close to the ceiling, or as far from the
"splash zone" as possible (see below for definition 
of the splash zone). As can be seen from the table 
of wiring sizes, it is advisable to place the enclosure 
as close to the fan as possible to reduce the costs 
of wiring and assist in installation.

‘Splash zone’

The ‘Splash Zone’ can be considered to be an area 
within a bathroom or shower room where a person
using the bath or shower can effectively reach. 
An arms reach is defined as 0.6 metres from the edge
of the bath or shower up to a height of 2.25 metres.

Procedure

1.

Remove two screws securing the cover and
remove the cover.

2. Position the base enclosure on mounting

surface and route cables through knockouts.
Mark the fixing points on the mounting surface
and secure using suitable fixings (by others).

3. Connect wiring as shown.

4. Replace cover.

Keep vents clear of obstruction.

Note: No earth is to be connected between 
transformer and fan.

Isolation - Before commencing work make sure
that the unit is electrically isolated from the mains
and switched live supply. 

Figure 11. 12V Transformer details.

Maintenance

General

A washable filter is fitted to protect the fan/motor assembly from
towel lint, talc etc. and to prolong the life of the unit. 
However, some fine dust may find its way through the filter 
and could build up on the motor and/or impeller. It is therefore
strongly recommended that all units are inspected and cleaned at
least every six months.

Procedure

At all times take care not to damage, distort or disturb the balance
of the impeller. Remove the filter and the electronic control module.
Spring aside the two clips and remove the fan module Inspect and
replace any damaged items.

Using a soft brush or dry cloth remove dust and dirt from the fan
module. Wash front cover in warm soapy water and dry 
thoroughly. Re-fit fan and electronic control module, replace front 
cover and secure with screws. Wash filter on tepid water to which
a little mild detergent has been added. Shake out excess water and
allow to dry naturally. Replace filter.  Refit the retaining screws 
(Fig 3). Test run the unit.

Replacement of Parts

Should any component need replacing Nuaire keep extensive

 

stocks

 

for quick delivery. Ensure that the unit is electrically isolated,

 

before carrying out any work. 

When ordering spare parts, please quote the serial number of the

 

unit and the ARC number of the purchase if possible.

(This information will be available on the fan label).

Warranty

The 5 year warranty starts from the day of delivery and includes

 

parts and labour for the first year.

 

The remaining period covers 

replacement parts only.

This warranty is void if the equipment is modified without 
authorisation, is incorrectly applied, misused, disassembled, or not 
installed, commissioned and maintained in accordance with the 
details contained in this manual and general good practice. 

The product warranty applies to the UK mainland and in 
accordance with Clause 14 of our Conditions of Sale. Customers 
purchasing from outside of the UK should contact Nuaire 
International Sales office for further details.

Service Enquiries

For technical assistance or further product information, please 
contact the After Sales Department.

Telephone 02920 858 400

Technical or commercial considerations may, from time to time, make it necessary to alter the design, performance and 

dimensions of equipment and the right is reserved to make such changes without prior notice.

75mm

147mm

Note to installing 

electrician: 

To avoid cable insulation

contact with hot 

transformer, always 

use the knockout at 

PCB end.

12V cables should not be fitted within 

50mm of 230V cables or on the same metal

cable tray/conduit.