NuAire FLAT2000L Скачать руководство пользователя страница 4

4

nuaire.co.uk 

029 2085 8400

23. 06. 17. Leaflet Number  670901

Installation and Maintenance

FLAT2000L/R Low Energy Positive Input Ventilation Unit

N

Mains power Smoke Nc contacts

L

Flatmaster

PCB

L       N 

 NC 

            C 

230V

     NO

Supply

230V 

Telephone 02920 858 400 

[email protected]

E

N

L

Optional

 lamp

N

L

Mains
230V
50Hz

Fan unit

3 Pole 

isolator

Fuse 3A

Remote Switch 

(Supplied)

3

4.2 Remote Switch

4.3 Smoke alarm automatic shut down 

If the unit is required to switch off in the event of smoke detection, 
alarms are available with separate relay bases from companies such as:

Dicon Safety products – www.diconsafety.co.uk

Aico Ltd – www.aico.co.uk

5.0 SETTING THE UNIT

The speed selector is located on the PCB (see figure 12). The unit 
has a choice of three speeds to suit the size of the dwelling and the 
moisture being generated. The unit is factory set at No 3-High Speed. 
We recommend that the unit is operated at this speed and the setting 
reduced if and when necessary in the future.

6.0 MAINTENANCE

The maintenance requirements for this product can be found in the 
“Product Safety – Essential Operational Checks” section, which is 
located in this document and includes the replacement of the filter 
(Our part number FLAT-FILTERKIT) every 12 months; this interval 
may need to be shortened, if the unit is operating under adverse 
environmental conditions.

7.0 WARRANTY

The unit has a 5 year warranty starting from the day of delivery and 
includes parts and labour for the first year. The remaining 4 years covers 
parts only. This warranty is conditional on the following:-

That the unit is installed strictly in accordance with this guide.

That the unit filters are removed and replaced at the 
recommended intervals.

This warranty is void if the equipment is modified without 
authorisation, is incorrectly applied, misused, disassembled, or not 
installed, commissioned and maintained in accordance with the details 
contained in this manual and general good practice.

The product warranty applies to the UK mainland and in accordance 
with Clause 14 of our Conditions of Sale. Customers purchasing from 
outside of the UK should contact Nuaire International Sales office for 
further details.

8.0 AFTER SALES

For technical assistance or further product information, including spare 
parts and replacement components, please contact the After Sales 
Department.

Figure 8.  Wiring the remote switch

Figure 9.  Typical wiring (refer to manufactures specific instructions).

Содержание FLAT2000L

Страница 1: ...ling supply grille is usually installed at high level in a central location within the hallway although discharging the air down the length of the hallway away from the front door should also prove acceptable Unit performance may be enhanced if an existing heat source can warm the discharged air e g by locating the discharge grille above a radiator Before commencing installation decide the best po...

Страница 2: ...to the wall Rear view of unit shown 2 4 Inlet Outlet grille installation If a fly screen is fitted it should be removed from both the internal and external grille NOTE When installing the internal grille the louvres must slant upwards to ensure the correct air circulation and the avoidance of unpleasant down draughts The outside wall input grille louvres must slant downwards Standard 100mm dia duc...

Страница 3: ...a switch in the fixed wiring in accordance with current IEE wiring regulations Electrical connection Please note the electrical connections to the unit should be carried out by a qualified electrician With the PCB cover removed see figure 4 pull the PCB forward to gain access to earth post behind Connect Earth cable to Earth post next to the grommet hole Slide PCB into slot and connect the mains s...

Страница 4: ...h is located in this document and includes the replacement of the filter Our part number FLAT FILTERKIT every 12 months this interval may need to be shortened if the unit is operating under adverse environmental conditions 7 0 WARRANTY The unit has a 5 year warranty starting from the day of delivery and includes parts and labour for the first year The remaining 4 years covers parts only This warra...

Страница 5: ...tional or incomplete Product Safety Essential Operational Checks Product Condition Installation Project Address Date Of Check Unit Code Unit Serial Number No action required Remedial action required Make safe and corrective action required Figure 10 FLAT2000 unit with cover installled Indicate Inlet Position 3 4 5 or 6 Indicate Supply Outlet Position Approx length of ductwork on inlet 600mm min Ap...

Отзывы: