NuAire DuctMaster DCB 315 Скачать руководство пользователя страница 8

8

Suspended horizontally from above.

Suspended vertically from above.

A

B

A1

B

B1

View on 

‘Y’

View on 

‘Z’

End view

Side view

End view

Side view

F

‘Z’

‘Y’

DCB315 2 & 4

DCB350 2 & 4

DCB400 2 & 4

DCB450 2 & 4

DCB500 2 & 4

DCB560 4 

DCB560 2 

DCB630 4 

DCB630 2 

DCB630 2 

298

339

384

424

484

562

530

616

596

596

348

389

434

474

534

612

580

666

646

646

265

266

218

319

294

256

256

391

391

391

188

229

274

314

374

452

420

506

486

486

656

675

708

784

830

841

841

943

943

943

811

847

905

1003

1076

1117

1117

1254

1254

1254

355

355

405

405

502

565

565

630

630

630

405

405

455

455

552

615

615

680

680

680

469

527

542

614

653

732

732

825

825

825

483

518

568

618

716

776

776

845

845

845

243

243

293

293

393

453

453

523

523

523

230

230

230

230

230

230

230

230

230

230

M8/M10

M8/M10

M10

M10

M10

M10

M10

M10

M10

M10

1041

1077

1194

1244

1362

1422

1422

1490

1490

1490

1351

1421

1588

1682

1854

1974

1974

2112

2112

2112

Unit 
Code

Dimensions (mm) between foot fixing hole centres

short

silencer

long

silencer

short

silencer

long

silencer

Drop**

rods and

bolt sizes

for AV

mounts

A      A1      B      B1      C        C       D    D1      E        E       F   

G      H      J        J

short

silencer

long

silencer

230

230

230

230

230

230

230

230

230

230

Dimensions of fixing centres

Supported horizontally from floor.

Fixing Details

Unit only

Installation and Maintenance  

DUCTMASTER BIFURCATED

Содержание DuctMaster DCB 315

Страница 1: ...commend that you contact NuAire before any blade angle changes are undertaken NuAire will not accept responsibility for damaged units when unauthorised personnel have altered blade angles Units are av...

Страница 2: ...88 326 168 49 43 DCB 560 553 605 606 633 565 278 168 43 4 Pole DCB 560 553 605 606 633 527 418 168 55 2 Pole DCB 630 622 674 651 729 615 428 168 65 4 Pole DCB 630 622 674 651 751 619 468 168 84 2 Pole...

Страница 3: ...n to escape from the motor casing It is essential therefore that these drain holes are positioned at the lowest point of the fan motor when the unit is horizontally mounted All bearings are pre packed...

Страница 4: ...st therefore that the inspection and if necessary cleaning bearing check should be carried out at regular intervals of a maximum of six months For a routine inspection check the tightness of all nuts...

Страница 5: ...nstructed cylindrical galvanised steel casing The casing is lined internally with sound absorbent material which has excellent acoustic properties is non hygroscopic and also incombustible The materia...

Страница 6: ...DAV5 DAV5 DAV5 DAV5 DAV5 DAV3 DAV5 DAV2 DAV2 DAV2 DAV2 DAV5 DAV5 DAV2 DAV5 DAV5 DAV5 DAV5 DAV5 DAV3 DAV5 DAV2 DAV2 DAV2 DAV2 DAV5 DAV5 DAV2 DAV5 DAV5 DAV5 DAV5 DAV5 DAV3 DAV5 DAV2 DAV2 DAV2 DAV2 DAV2...

Страница 7: ...flange Flexibleductmaterialisflameproof and resistant to chemicals ozone oil grease and heat up to 900 C 2300 C see codes Thespigotisoflightgaugegalvanisedsteel The connector is airtight waterproof an...

Страница 8: ...05 455 455 552 615 615 680 680 680 469 527 542 614 653 732 732 825 825 825 483 518 568 618 716 776 776 845 845 845 243 243 293 293 393 453 453 523 523 523 230 230 230 230 230 230 230 230 230 230 M8 M1...

Страница 9: ...ods only required on units up to 630 Additional rod positions are shown shaded INSTALLATION NOTES For internal use it is good practice that the unit be installed so that the motor tunnel is vertical t...

Страница 10: ...PEED TAP PAM WOUND MOTOR D O L starting both speeds 400V 3 phase 50Hz supply 1U 1V 1W 2U 2V 2W Motor terminal box NOTE LOW SPEED Supply 1U 1V 1W HIGH SPEED Supply 2U 2V 2W LINK 1U 1V 1W 3 Phase for St...

Страница 11: ...age Directive Applied Harmonised Standards E50081 1 EN50082 1 EN60204 1 EN60335 2 80 Basis of Self Attestation Quality Assurance to BS EN ISO 9001 BSI Registered Firm Certificate No FM 149 Signature o...

Страница 12: ...ives 98 37 EC Machinery Directive 93 44 EEC Amendment to the Machinery Directive Applied Harmonised Standards EN292 1 EN292 2 EN294 EN29001 Applied National Standards BS848 Parts One Two and Five Sign...

Страница 13: ...orientation 4 2 Where installation accessories are supplied with the specified equipment eg wall mounting brackets They are to be used to support the equipment only Other system components must have s...

Страница 14: ...rom the date of delivery and includes parts and labour for the first year The labour element is subject to full free and safe access to the equipment as recommended by the CDM regulations The remainin...

Страница 15: ...state Caerphilly Mid Glam CF8 1XH United Kingdom Telephone 02920 885911 Facsimile 02920 887033 Leaflet No 670679 Technical or commercial considerations may from time to time make it necessary to alter...

Страница 16: ...16...

Отзывы: