1.0  Important notes to installers

The successful operation of this unit depends entirely upon

installation and ongoing maintenance being carried out in 

accordance with these instructions.

Please read this guide in its entirety before installation and then

repeat the exercise step by step to ensure satisfactory completion.

Suitably qualified persons may achieve installation of the unit, 

however the provision of the electrical supply and the connection of

the unit to the mains supply should only be carried out by a qualified

electrician.

The unit can be installed in a home with a “cold roof” construction. 

Note: If a floor is higher than 4.5m the requirements in sections

5.2 and 10.2 must be followed.

Note: 3 storey properties must be fitted with an aluminium 

diffuser - see section 5.2.

2.0  General description

The unit is a unique low energy Positive Input Ventilation (LEPIV)

unit. Unlike conventional LEPIV units which only draw in external air

via the loft in a “cold roof”, the unit is capable of drawing in external

air from a roof location via an inlet spigot fitted with a low energy

open/close damper.

It is not neessary for the home owner to program or operate the unit

in any way, as the 365 is totally automatic.

The unit intelligently decides where the fresh air will be supplied

from.

If the loft temperature is below 24

O

C then the unit will take fresh air

from the loft.

If the loft temperature is above 24

O

C then cool fresh air will be taken

from outside the dwelling.

If the loft temperature is 19

O

C to 24

O

C and the house is cooler than

this, then the unit goes into heat recovery mode. The unit will increase

in speed and supply more air to the property.

The unit can be boosted to obtain maximum ventilation by the 

operation of a boost switch.

S

etting switch is located 

on the rear of the fan case.

150mm dia.

Flexible Ducting 

200mm dia.

Flexible Ducting 

Air from loft 

From outside

air supply 

Diffuser

Drimaster365

Low Energy Positive Input Ventilation Unit

Installation and Maintenance Details

1

11. 06. 15. Leaflet Number 671429

Figure 1. General view of unit installed on roof joists in a loft.

Nuaire Limited

Western Industrial Estate  Caerphilly   United Kingdom  CF83 1NA  

T: 029 2085 8400   F: 029 2085 8444   E: [email protected]   W: www.nuaire.co.uk

The EMC Directive 

20

1

4/

30

/E

U

  

The Low Voltage 

directive 

20

14

/

3

5/E

U

Содержание Drimaster365

Страница 1: ...got fitted with a low energy open close damper It is not neessary for the home owner to program or operate the unit in any way as the 365 is totally automatic The unit intelligently decides where the...

Страница 2: ...to ensure that the diffuser is NOT placed within 1 metre of a smoke alarm If the diffuser cannot be repositioned two sides of the diffuser must be closed off using the foam strips supplied to encourag...

Страница 3: ...7 0 Siting the Remote Sensor The Remote Temperature Sensor incorporates a clip in fixing bracket which can be removed for easy fitting to a suitable surface figure 8 a Select a suitable location for t...

Страница 4: ...Tel 08705 002555 Fax 08705 002666 E mail info nuaire co uk Part No Description DRI365 SOFFITKIT see 9 1 775229 128mm x 260mm soffit grille PVC933WH 3m length of 222mm x 90mm flexible PVC ducting for...

Страница 5: ...all supply air ducting Similarly supply and extract air grilles should be at least 300mm apart 150mm dia insulated ducting connected to unit spigot using dynotie connector 150mm dia pipe Part No PVC13...

Страница 6: ...5 shows the LED s that when illuminated indicate the corresponding air volume for the unit For example a one bedroom one person bungalow recommended setting would be speed one A five bedroom seven per...

Страница 7: ...year warranty starting from the day of delivery and includes parts and labour for the first year The remaining 4 years covers parts only This warranty is conditional on the following a That the unit...

Страница 8: ...e noted 5 1 Where access to any part of equipment which moves or can become electrically live are not prevented by the equipment panels or by fixed installation detail eg ducting then guarding to the...

Отзывы: