9.0 Speed Settings

The dMEV+H is pre-set to achieve 6 l/s Continuous and 13 l/s on
boost. This can however be changed to 8 l/s Continuous and 18 l/s
on boost. To change these speed setting you will need to change the 

jumper position within the fan unit (fig. 8). To do this you will need
to remove the 2 fixing screws on the motor cap (shown in fig 2a).

Installation and Maintenance

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan

Technical or commercial considerations may, from time to time, 

make it necessary to alter the design, performance and 

dimensions of equipment and the right is reserved to make such

changes without prior notice.

10

. 0

5

. 17. Leaflet Number 671665

4

11.0 Maintenance

The fan unit does not require any maintenance. However, for 
optimum performance, it is advisable to remove any accumulated

 

dust with a low power vacuum cleaner.

Note: Installation and Maintenance of the equipment must 
be as directed in the instructions provided with the unit.

12.0 Warranty

The 5 year warranty starts from the day of delivery and includes 
parts and labour for the first year. The remaining 4 years covers 
replacement parts only. 

This warranty is void if the equipment is modified without 
authorisation, is incorrectly applied, misused, disassembled, or not 
installed, commissioned and maintained in accordance with the 
details contained in this manual and general good practice. 

Telephone 02920

 

858

 

400

SL 

N

Low  High

Unit is fixed speed.

Select between either 
Low or High speed with 
the jumper position.

i.e. Bathroom installation
Low speed (Pre-set 
factory position).

Speed

Low

Low

High

High

Setting:

Continuous Boost Continuous Boost

Air Flow:

6 l/s

13 l/s 8 l/s

18 l/s

Figure. 8.

Figure 9a.

Figure 9b.

Humidity sensor

Humidity switch

230V Live

230V Neutral

230V Switch live

1

2

3

10.0 Humidity Set Point

The dMEV+H is pre-set to boost when it senses a relative humidity
(%RH) of 80% however this can be changed to suit the installation.
To do this you will need to access the PCB within the unit.  

On the PCB you will need to alter the humidity switch (fig 9a) 
configuration to suit the configurations in (fig 9b).

ON 

ADE02

 2

ON 

ADE02

 2

ON 

ADE02

 2

ON 

ADE02

 2

60% RH

70% RH

80% RH

90% RH

Switch actuator

The product warranty applies to the UK mainland and in accordance 
with Clause 14 of our Conditions of Sale. Customers purchasing from 
outside of the UK should contact Nuaire International Sales office for 
further details.

13.0 After Sales

For technical assistance or further product information, including spare 
parts and replacement components, please contact the After Sales 
Department.