G

Standard Case

A

D

Dia.

 

 

Installation, Operating and Maintenance Instructions

DAVE Extract Fans (BC Models)

2

09. 04. 15. Leaflet Number 671680

5.0 Dimensions & Weights - DAVE Basic Control Extract Fans

 

B

C

J

H

G

Extended Case 

A

D

Dia.

Fig 3: Example Code: DE2-BC

Unit Code 

Extended

B

C

‘D’

G

H

J

Case A 

Dia

DE1A-BC

1005

559

233

150

116

116

59

DE2A-BC

1005

696

300

200

116

116

59

DE2HA-BC

1005

696

300

200

116

116

59

DE3A-BC

1005

780

345

200

116

116

59

DE4A-BC

1005

840

370

250

116

116

59

DE4HA-BC

1005

840

370

250

116

116

59

DE5A-BC

1005

984

410

315

116

116

59

DE6A-BC

1005

1092

455

400

116

116

59

DE7A-BC

1005

1200

500

400

116

116

59

Weights (kg) Extract fans

Unit Code 

Unit Weights (kg)

Unit Code

Unit Weights (kg)

DE1BC

25

DE5-BC

59

DE1A-BC

30

DE5A-BC

70

DE2-BC

25

DE6-BC

69

DE2A-BC

40

DE6A-BC

75

DE2H-BC

25

DE7-BC

82

DE2HA-BC

45

DE7A-BC

90

DE3-BC

30

DE3A-BC

50

DE4-BC

35

DE4A-BC

67

DE4H-BC

40

DE4HA-BC

67

Unit Code 

Standard

B

C

‘D’

G

H

J

Case A

Dia

DE1-BC

605

559

233

150

116

116

59

DE2-BC

605

696

300

200

116

116

59

DE2H-BC

605

696

300

200

116

116

59

DE3-BC

605

780

345

200

116

116

59

DE4-BC

605

840

370

250

116

116

59

DE4H-BC

605

840

370

250

116

116

59

DE5-BC

605

984

410

315

116

116

59

DE6-BC

605

1092

455

400

116

116

59

DE7-BC

605

1200

500

400

116

116

59

Dimensions Extract fans with standard case

Dimensions Extract fans with extended case ‘A’

Fig 4: Example Code: DE2A-BC

Содержание DAVE

Страница 1: ... with drop rods Figure 2 Units supplied with four mounting brackets with 1 x M8 hole in each 4 0 Motor Details Unit Code Voltage Input Start f l c Nominal phase power current amps fan frequency kW amps speed DE1 BC DE1A BC 230 1 50 0 03 0 27 0 27 3770 DE2 BC DE2A BC 230 1 50 0 088 0 75 0 75 3200 DE2H BC DE2HA BC 230 1 50 0 17 1 4 1 4 4060 DE3 BC DE3A BC 230 1 50 0 17 1 4 1 4 2860 DE4 BC DE4A BC 23...

Страница 2: ...116 116 59 DE7A BC 1005 1200 500 400 116 116 59 Weights kg Extract fans Unit Code Unit Weights kg Unit Code Unit Weights kg DE1BC 25 DE5 BC 59 DE1A BC 30 DE5A BC 70 DE2 BC 25 DE6 BC 69 DE2A BC 40 DE6A BC 75 DE2H BC 25 DE7 BC 82 DE2HA BC 45 DE7A BC 90 DE3 BC 30 DE3A BC 50 DE4 BC 35 DE4A BC 67 DE4H BC 40 DE4HA BC 67 Unit Code Standard B C D G H J Case A Dia DE1 BC 605 559 233 150 116 116 59 DE2 BC 6...

Страница 3: ...x speed TK TK Motor Thermal Overload Isolator by others 230V 50Hz N L N L V 1 10V SIG 0V 0V Speed control signal IV fan off Alternatively link from V to SIG for max speed T Tach output open collector 1 pulse per revolution electrically isolated Isolation Before commencing work make sure that the unit and Nuaire control are electrically isolated from the mains supply 3 09 04 15 Leaflet Number 67168...

Страница 4: ...n out the interior as necessary Check all parts for security and that the impeller rotates freely taking care not to disturb the balance Ensure all control components are secure and clean refit the cover Lubrication Motors are fitted with sealed for life bearings and do not require any lubrication Filter care replacement The filter where applicable will require cleaning on a regular basis The freq...

Страница 5: ...details contained in this manual and general good practice 10 0 Spares for Dave Extract fans Spare parts and replacement components are available from Nuaire Ltd Please contact us on the numbers below for further details G3 Filter applicable to Extended case type A only Unit Size Replacement Part No DE1A D1A G3FILTERKIT DE2A D2A G3FILTERKIT DE2HA D2HA G3FILTERKIT DE3A D3A G3FILTERKIT DE4A D4A G3FI...

Страница 6: ...arranged so as not to bear on the casing 3 3 Equipment stored on site prior to installation should be protected from the weather and steps taken to prevent ingress of contaminants 4 0 OPERATIONAL LIMITS 4 1 It is important that the specified operational limits for the equipment are adhered to e g operational air temperature air borne contaminants and unit orientation 4 2 Where installation accesso...