AVS-NC

Installation Manual

1.3 Personal Protective Equipment

The following minimum Personal Protective Equipment (PPE) is 
recommended when interacting with Nuaire product:

Protective Steel Toed Shoes - 

when handling heavy objects.

 

Full Finger Gloves (Marigold PU800 or equivalent) - 

when 

handling sheet metal components. 

Semi Fingerless Gloves (Marigold PU3000 3DO or equivalent) 

- when conducting light work on the unit requiring tactile 
dexterity. 

Safety Glasses

 - when conducting any cleaning/cutting operation 

or exchanging filters. 

Reusable Half Mask Respirators 

- when replacing filters which 

have been in contact with normal room or environmental air.

Nuaire would always recommend a site specific risk assessment by a 
competent person to determine if any additional PPE is required. 

2.0 INTRODUCTION

AVS

 

units are rectangular in section and shall be double skinned with 

35mm infill panels and shall be manufactured from heavy gauge, 
corrosion resistant Aluzinc steel, internally lined with acoustic material. 
Four matching mounting feet are supplied with the unit. Units have 
circular rigid spigots at each end. The spigot ends are fully detachable 
for relocation onto matching attenuators. The fan should be with an 
‘inline assembly’, positioned in series for optimum performance. 

Units incorporate fully detachable top or bottom panels for 
maintenance and inspection purposes. 

AVS 1 units have a loose 

control module for surface mounting up to 1 metre away from 
main unit.  AVS 8 and 9 units incorporate split access panels.

2.1 Code Description: 

1

2

3

-

4

AV

S

1

-

NC

   

1. Range:  

 

Aire-Volve

2. Fan Type: 

 

= Single Fan

3. Unit Size:  

 

1, 2, 3, 4, 4L, 5, 6, 7, 8, 9

4. Control Type 

 

NC

 = No Control

 

Airflow

General View Of A Standard AVS Unit Configuration

 

Typical AVS Unit (2-6) With Silencer And Four Mounting 
Feet Employed For Ceiling Void Installation

Typical AVS-A Unit (2-6) With Four Mounting 
Feet Employed For Ceiling Void Installation

3.0 HANDLING

Upon receipt of the equipment, an inspection should be made. Before 
commencement of lifting, ensure that normal equipment safety checks 
have been carried out.

A unit / module should be removed from the vehicle using a fork lift 
or crane. Always handle with care to avoid damage and distortion, and 
where lifting slings are employed use spreaders to ensure slings do 
not come into contact with the unit case, or control pack. Correctly 
position slings to avoid twisting of the unit case and observe the 
centre of gravity before the final lift is made. 

The weight of the unit is 

available on the unit rating plate. 

Dependent on model and size, units may be supplied in single or multi-
modular sections. Handle each section individually do not stack for 
lifting or storage.

Содержание AVS-NC

Страница 1: ...not play with the appliance Cleaning and user maintenance shall not be carried out by children 1 1 Symbols GENERAL WARNING Signifies a general warning regarding hazard specified by supplementary information ELECTRIC SHOCK This unit must be completely electrically isolated before any panels are removed Check mains supply and control connections ROTATING PARTS This unit contains fast moving rotation...

Страница 2: ...should be with an inline assembly positioned in series for optimum performance Units incorporate fully detachable top or bottom panels for maintenance and inspection purposes AVS 1 units have a loose control module for surface mounting up to 1 metre away from main unit AVS 8 and 9 units incorporate split access panels 2 1 Code Description 1 2 3 4 AV S 1 NC 1 Range Aire Volve 2 Fan Type S Single Fa...

Страница 3: ...ned for underside access Figure 2 3 4 4 Vertically Wall Mounted Rigid Units Utilising the Aire Volve Vertical Hanging Bracket kit that includes wall hanging brackets and hinges Figures 5 and 6 The unit case has captive M8 nuts which can be used after removing the M8 plugging screws Units should always be positioned with sufficient space to allow the access panel to extend forward Only suitable for...

Страница 4: ...nstalled NAV 2 5 Floor Mounted Application 4 6 Dimensions mm Weights kg 4 6 1 AVS Units 12 AVS Dimensions A C D B B1 A1 Unit Code A A1 Bracket Centre Points B B1 Bracket Centre Points C D Weight kg AVS1 580 344 535 576 246 200 27 AVS2 615 380 535 646 281 200 24 AVS3 745 510 672 713 329 250 43 AVS4 788 553 672 713 373 315 47 AVS4L 914 678 818 860 391 315 67 AVS5 914 678 818 860 428 315 66 AVS6 1087...

Страница 5: ...43 AVS7 MSS Standard 1000 1013 575 41 AVS7 MSL Large 1500 1013 575 98 AVS8 AVS8 MSM Mini 500 1237 615 51 AVS8 MSS Standard 1000 1237 615 83 AVS8 MSL Large 1500 1237 615 114 AVS9 AVS9 MSM Mini 500 1237 615 51 AVS9 MSS Standard 1000 1237 615 92 AVS9 MSL Large 1500 1237 615 125 4 7 Unit Access Unit can be installed inverted for ease of access to control e g control opposite side If inverted it will r...

Страница 6: ... before fitting and use fixing brackets Correctly align fixing brackets halves Figure 17 and assemble using M8 cap head bolt and nut supplied with bracket Tighten bolts to ensure a full seal between silencer and unit is achieved Figure 18 Airflow Fan unit outlet Fan unit inlet Attenuator inlet pod configuration Attenuator outlet pod configuration Airflow 16 Typical Side Section View Of Outlet Sile...

Страница 7: ...al Connection Mandatory External Connection A1 Rotary Isolating Switch Supplied by Customer A3 Close to Open IO Damper Supplied by Customer W2 Dirty Filter Alarm Open Alarm Supply Fan E A1 Neutral Live 1 Live 2 Live 3 Supply Fan Control A1 Main Supply Connection IO Damper N IO Damper Close Supply Fan L1 Supply Fan 10v Supply Fan 0 10v Supply Fan 0v A3 IO Damper Open A2 Supply Fan N W2 Supply Air f...

Страница 8: ...rts aluminium extrusion heating cooling coils and other metallic items can be segregated and fully recycled EPP plastic ducting nylon corner pieces plastic heat exchangers packaging material and other plastic components can be segregated into mixed plastic and widely recycled Cardboard packaging wood used filters and other paper components can be largely recycled or fully processed in energy from ...

Отзывы: