background image

1

05. 04. 22. Document Number  671572

Nuaire | Western Industrial Estate | Caerphilly | CF83 1NA | nuaire.co.uk

AVS-NC

Indoor Use Single Fans with No Control 

 

Installation Manual

1.0 SAFETY INFORMATION

• 

The provision of the electrical supply and the connection of the unit to the electrical supply must 
be carried out by a qualified electrician.

• 

Isolate from power supply before removing any covers. During installation / maintenance ensure 
all covers are fitted before switching on the mains supply. 

• 

All-pole disconnection from the mains as shown in the wiring diagram must be incorporated 
within the fixed wiring and shall have a minimum contact separation of 3mm in accordance with 
latest edition of the wiring regulations.

• 

This unit must be earthed.

• 

Ducting must be securely fixed with screws to the spigot to prevent access to live parts. Duct 
runs terminating close to the fan must be adequately protected by suitable guards.

• 

This appliance should not be used by children or persons with reduced physical, sensory or 
mental capabilities or lack of experience and knowledge, unless they have been given supervision 
or instruction concerning the safe use of the appliance by a person responsible for their safety. 
Children shall not play with the appliance. Cleaning and user maintenance shall not be carried 
out by children.

1.1 Symbols

 

GENERAL WARNING 

 

 

Signifies a general warning regarding hazard specified by supplementary information.

 

ELECTRIC SHOCK

 

 

 

This unit must be completely electrically isolated before any panels are removed. Check  

 

 

mains supply and control connections. 

 

ROTATING PARTS 

 

 

 

This unit contains fast moving rotational parts which may start automatically. It is the  

 

 

sole responsibility of the installer to adequately guard these components.

 

REFER TO INSTRUCTION MANUAL

 

 

 

Read and understand the installation and maintenance manual before installing,    

 

 

operating or maintaining this product.

1.2 Important Information

This manual contains important information on the safe and 
appropriate assembly, transport, commissioning, operation, 
maintenance, disassembly and simple troubleshooting of the product.

While the product has been manufactured according to the accepted 
rules of current technology, there is still a danger of personal injury or 
damage to equipment if the following general safety instructions and 
the warnings contained in these instructions are not complied with.

Read these instructions completely and thoroughly before 
working with the product.

Keep these instructions in a location where they are accessible 
to all users at all times.

Always include the operating instructions when you pass the 
product on to third parties.

Содержание AVS-NC

Страница 1: ...not play with the appliance Cleaning and user maintenance shall not be carried out by children 1 1 Symbols GENERAL WARNING Signifies a general warning regarding hazard specified by supplementary information ELECTRIC SHOCK This unit must be completely electrically isolated before any panels are removed Check mains supply and control connections ROTATING PARTS This unit contains fast moving rotation...

Страница 2: ...should be with an inline assembly positioned in series for optimum performance Units incorporate fully detachable top or bottom panels for maintenance and inspection purposes AVS 1 units have a loose control module for surface mounting up to 1 metre away from main unit AVS 8 and 9 units incorporate split access panels 2 1 Code Description 1 2 3 4 AV S 1 NC 1 Range Aire Volve 2 Fan Type S Single Fa...

Страница 3: ...ned for underside access Figure 2 3 4 4 Vertically Wall Mounted Rigid Units Utilising the Aire Volve Vertical Hanging Bracket kit that includes wall hanging brackets and hinges Figures 5 and 6 The unit case has captive M8 nuts which can be used after removing the M8 plugging screws Units should always be positioned with sufficient space to allow the access panel to extend forward Only suitable for...

Страница 4: ...nstalled NAV 2 5 Floor Mounted Application 4 6 Dimensions mm Weights kg 4 6 1 AVS Units 12 AVS Dimensions A C D B B1 A1 Unit Code A A1 Bracket Centre Points B B1 Bracket Centre Points C D Weight kg AVS1 580 344 535 576 246 200 27 AVS2 615 380 535 646 281 200 24 AVS3 745 510 672 713 329 250 43 AVS4 788 553 672 713 373 315 47 AVS4L 914 678 818 860 391 315 67 AVS5 914 678 818 860 428 315 66 AVS6 1087...

Страница 5: ...43 AVS7 MSS Standard 1000 1013 575 41 AVS7 MSL Large 1500 1013 575 98 AVS8 AVS8 MSM Mini 500 1237 615 51 AVS8 MSS Standard 1000 1237 615 83 AVS8 MSL Large 1500 1237 615 114 AVS9 AVS9 MSM Mini 500 1237 615 51 AVS9 MSS Standard 1000 1237 615 92 AVS9 MSL Large 1500 1237 615 125 4 7 Unit Access Unit can be installed inverted for ease of access to control e g control opposite side If inverted it will r...

Страница 6: ... before fitting and use fixing brackets Correctly align fixing brackets halves Figure 17 and assemble using M8 cap head bolt and nut supplied with bracket Tighten bolts to ensure a full seal between silencer and unit is achieved Figure 18 Airflow Fan unit outlet Fan unit inlet Attenuator inlet pod configuration Attenuator outlet pod configuration Airflow 16 Typical Side Section View Of Outlet Sile...

Страница 7: ...al Connection Mandatory External Connection A1 Rotary Isolating Switch Supplied by Customer A3 Close to Open IO Damper Supplied by Customer W2 Dirty Filter Alarm Open Alarm Supply Fan E A1 Neutral Live 1 Live 2 Live 3 Supply Fan Control A1 Main Supply Connection IO Damper N IO Damper Close Supply Fan L1 Supply Fan 10v Supply Fan 0 10v Supply Fan 0v A3 IO Damper Open A2 Supply Fan N W2 Supply Air f...

Страница 8: ...rts aluminium extrusion heating cooling coils and other metallic items can be segregated and fully recycled EPP plastic ducting nylon corner pieces plastic heat exchangers packaging material and other plastic components can be segregated into mixed plastic and widely recycled Cardboard packaging wood used filters and other paper components can be largely recycled or fully processed in energy from ...