background image

NTI UNIMUX 2-Port USB DVI KVM Switch 

 

11

 
 
It is also possible to configure the UNIMUX to emulate a specific international Sun keyboard regardless of what actual keyboard is 
connected.  This is recommended when the CPU needs the layout code (i.e. a SUN CPU) and the keyboard doesn't have an 
explicit layout code (i.e. some Windows keyboards).   To do this, manually set the UNIMUX to indicate the international keyboard 
identification number to the CPU using the following procedure;  
              

1.  Connect the keyboard to be used to the UNIMUX 
2.  Disconnect power from the UNIMUX for at least 3 seconds 

             3.  Reconnect power to the UNIMUX 
             4.  Enter Command Mode   
             5.  Type Lxx, where xx is the number from the list below that corresponds to the desired country code    
             6.  Exit Command Mode 
             7.  Disconnect power from the UNIMUX for at least 3 seconds 
             8.  Reconnect power to the UNIMUX 
             9.  Reboot the CPU connected to the UNIMUX.  
                    

                             

Country Codes 

00 Not 

Supported  18 Netherlands/Dutch 

01 Arabic 

19 Norwegian 

02 Belgian 

20 Persian 

(Farsi) 

03 Canadian-Bilingual 

21 Poland 

04 Canadian-French 22 Portuguese 
05 Czech 

Republic  23 Russia 

06 Danish 

24 Slovakia 

07 Finnish 

25 Spanish 

08 French 

26 Swedish 

09 German 

27 Swiss/French 

10 Greek 

28 Swiss/German 

11 Hebrew 

29 Switzerland 

12 Hungary 

30 Taiwan 

13 International 

(ISO) 

31 Turkish 

14 Italian 

32 UK 

15 Japan 

(Katakana) 

33 US 

16 Korean 

34 

 Yugoslavia 

17 Latin 

American  35-99 

Reserved 

 
 
 
 
 

TROUBLESHOOTING 

 
 

1.  Verify all cables are securely connected and that the installation procedure was carefully followed. 
2.  If a CPU seems to be locked up, 

  cycle the power to the UNIMUX OFF,  then  ON. 

  unplug the "USB DEVICES" keyboard and mouse cables (not the "CPU x" keyboard and mouse) from the UNIMUX and 

reconnect them. 

  reset default values as described on page 7.  

  reboot the CPU 

 

If the UNIMUX still seems work improperly, help may be found in the Frequently Ask Questions (FAQ’s) section of our 

website at http://www.netwoktechinc.com or call us directly at (

800) 742-8324 (800-RGB-TECH)

 or 

(330) 562-7070 

 and we 

will be happy to assist in any way we can.   

 
 
 
 
 
 
 
 
 
 
 
 

Содержание UNIMUX-DVI-2

Страница 1: ...MAN045 Rev Date 5 4 2009 UNIMUX DVI 2 2 Port USB DVI KVM Switch Installation and Operation Manual UNIMUXTM Series ...

Страница 2: ...r transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written consent of Network Technologies Inc 1275 Danner Drive Aurora Ohio 44202 CHANGES The material in this guide is for information only and is subject to change without notice Network Technologies Inc reserves the right to make changes in the product design without reservation a...

Страница 3: ...rackballs with MACs 8 KEYBOARD FEATURES 9 Keyboard To Computer Translation 9 Translation Capabilities 9 Translation Tables 9 International Sun Keyboards 10 TROUBLESHOOTING 11 INDEX 12 WARRANTY INFORMATION 12 TABLE OF FIGURES Figure 1 Connect the keyboard mouse and AC adapter 3 Figure 2 Connect a DVI enabled monitor 3 Figure 3 Connect CPU cables 4 Figure 4 Compatible device combinations 5 Figure 5 ...

Страница 4: ...on 1 0 or above including USB WINxx USB MAC USB SUN Note UNIMUX DVI 2 is fully compliant with USB standards 1 0 1 1 OPTION UNIMUX DVI 2 NBSC USB DVI KVM switch with no Command Broadcast or Scan modes MATERIALS Materials Supplied with this kit NTI UNIMUX DVI 2 Switch 120V at 60Hz 5VDC 0 5A AC Adapter Domestic Only OR 120 240V at 50 60Hz 5VDC 2 0A AC Adapter Foreign or Domestic Line Cord country spe...

Страница 5: ...o a specific CPU or to change the switch operating mode 5 MONITOR for connection of the user DVI enabled video monitor 6 VIDEO x female DVI connectors for connecting DVI cables from CPUs 7 CPU x USB type B female connectors for connection of USB device cables from CPUs 5 6 7 Rear View of UNIMUX DVI 2 Monitor Video 2 Video 1 CPU 2 CPU 1 NTI NETWORK TECHNOLOGIES INCORPORATED Tel 330 562 7070 1275 Da...

Страница 6: ...pter to the port labeled 5VDC Figure 1 Connect the keyboard mouse and AC adapter 5 Connect a DVI enabled monitor to the female DVI port labeled MONITOR on the UNIMUX Be sure to tighten the two screws on the monitor cable connector to the UNIMUX securely Figure 2 Connect a DVI enabled monitor USB Keyboard USB Mouse USB Type A Male Connectors USB Type A male 5 VDC Adapter AC ADAPTER Barrel Inside ba...

Страница 7: ...X Be sure to tighten the two screws on the cable connector to the UNIMUX securely 8 Repeat steps 6 and 7 for connecting a second USB CPU to the ports labeled CPU 2 and VIDEO 2 See Fig 3 Figure 3 Connect CPU cables DVI IS xx MM USB AB xxM Rear View of USB CPU USB Type A male USB Type B male USB TYPE A PORTS DVI VIDEO PORT Rear View of UNIMUX DVI 2 Monitor Video 2 Video 1 CPU 2 CPU 1 NTI NETWORK TEC...

Страница 8: ...page 2 item 2 A USB hub single or multi port can be used provided only USB input devices are plugged into it Only a USB Windows or SUN keyboard or USB mouse may be connected to the USB port on a USB MAC keyboard A maximum of 8 input devices may be connected to the UNIMUX either directly or through hubs See Fig 4 for some examples of input device combinations that can be used with the UNIMUX Figure...

Страница 9: ...MODE CPUx LED INDICATION COMMAND Both LEDs illuminated SCAN One LED flashing BROADCAST Both LEDS flashing alternately NORMAL One LED illuminated solid Keyboard Control In order to control the other features of the switch with the keyboard Command Mode must be enabled To enter Command Mode from the keyboard Press When the Command Mode is enabled all 3 status lights on the keyboard will illuminate a...

Страница 10: ...PRESSED PRESS CONSECUTIVELY or PRESS EITHER KEY KEY SYMBOLS LEGEND I select the next higher port ex 01 02 or D or select the next lower port ex 02 01 T xxx from 002 to 255 ie t002 would set the time out period for 2 seconds 0 2 x 0 9 x 0 9 x Esc Note The user must exit Command Mode to use the CPU s in the selected mode P P0x would be P01 or P02 1 2 x 0 S When toggled to ON Scan Mode will be indica...

Страница 11: ...d Mode for keystrokes to reach attached CPUs NOTE The mouse is disabled leaving only the keyboard active during Broadcast Mode NOTE Broadcast Mode not available on model UNIMUX DVI 2 NBSC Normal Mode The UNIMUX is in Normal Mode when only the LED for the active CPU is illuminated solid not flashing as in Scan Mode When in Normal Mode the user is controlling only the CPU to which the user is connec...

Страница 12: ...ull functionality Full functionality except Application Key Apple Pro Keyboard Extra keys emulation Extra Keys not supported Eject Mute Volume Volume Full functionality Sun Mouse Full functionality Full functionality Full functionality Wheel Mouse Full functionality Full functionality Full functionality Apple Mouse Right button emulation Full functionality Right button emulation Translation Tables...

Страница 13: ... 3 Disconnect power to the UNIMUX for at least 3 seconds 4 Reconnect power to the UNIMUX 5 Reconnect the CPU to the UNIMUX Enter Enter Ctrl Shift Shift Caps Lock Tab Esc Ctrl Alt Backspace Num Lock Enter Enter Alt Graph Shift Shift Caps Lock Tab Esc Ctrl Alt Backspace Num Lock Help Stop Props Front Open Find Cut Paste Copy Undo Again Com pose enter return control shift shift caps Lock tab esc cont...

Страница 14: ...Supported 18 Netherlands Dutch 01 Arabic 19 Norwegian 02 Belgian 20 Persian Farsi 03 Canadian Bilingual 21 Poland 04 Canadian French 22 Portuguese 05 Czech Republic 23 Russia 06 Danish 24 Slovakia 07 Finnish 25 Spanish 08 French 26 Swedish 09 German 27 Swiss French 10 Greek 28 Swiss German 11 Hebrew 29 Switzerland 12 Hungary 30 Taiwan 13 International ISO 31 Turkish 14 Italian 32 UK 15 Japan Katak...

Страница 15: ...yboards 10 Toubleshooting 11 USB hub 5 USB AB x MM 4 WARRANTY INFORMATION The warranty period on this product parts and labor is two 2 years from the date of purchase Please contact Network Technologies Inc at 800 742 8324 800 RGB TECH or 330 562 7070 or visit our website at http www networktechinc com for information regarding repairs and or returns A return authorization number is required for a...

Отзывы: