2
CONFIGURE THE JUMPERS
Configure the jumpers on the E-AVDS-CELC for connection to either Pulse or Tone dialing (default is Tone) to send voice messages
and to be triggered by either the Normally-Closed (N.C.)or Normally-Open (N.O.) relay contact on the E-xD. In the image below, the
jumpers are set for Tone dialing and connection to the N.O. terminal.
To set the “normal” relay state to Normally-Open, apply the J2 jumper to the center and right pin, and J3 jumper to the center and left
pin. In this configuration, a relay closure will trigger an alert state, activating the dialer.
To set the “normal” relay state to Normally-Closed, apply the J2 and J3 jumpers to the center and left pins. In this configuration, a
relay open condition will trigger an alert state, activating the dialer.
NOTE: The “VOLTAGE” jumper position is not used in conjunction with the E-xD.
With the jumpers properly set, and the rear panel securely mounted, re-assemble the case.
J1
J2
J3
J3
J2
J1
Jumpers here configured for Tone dialing and Normally-Open trigger
RESET
BUTTON
RESET
BUTTON
PRESS RESET BUTTON
TO RESET PASSWORD TO
“911”
Содержание E-AVDS-CELC
Страница 4: ...4...