![NTI AG LinMot E1030 Series Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/nti-ag/linmot-e1030-series/linmot-e1030-series_installation-manual_1715274006.webp)
Controller Series E1030/2030/4030
NTI AG
Installation: E1030/E2030/E4030 series / 16.09.2005
Page 6/12
Description of the connectors / Interfaces
Power Supply
Power Connector Motor
1 GND
2 +
Power Connector Signal
1 PWR
2 GND
Power Connector
Motor
GND
48...72VDC
GND internally
connected to
controller housing
Internal
Fuse 10AT
Supply GND
must be externally
connected to earth
GND
1
2
PWR Motor +
48...72VDC
Power Connector
Signal
GND
24...48VDC
GND internally
connected to
controller housing
Supply GND
must be externally
connected to earth
1
GND
3
24...48VDC
Internal
Fuse 500mAT
PWR
2 3
1
Power Supply Motor:
Wiring: 2.5 mm² (AWG12), max length 5 m
Supply Voltage 48...72 VDC. Absolute max. Rating 72VDC + 5%
Supply voltage for PWR Signal and PWR Motor may be different
Motor Supply GND must be externally connected to earth
Power Supply Signal:
Wiring: 1.5 mm² (AWG16), max length 5 m
Supply Voltage 24...48VDC. Absolute max. Rating 48VDC + 10%
Supply voltage for PWR Signal and PWR Motor may be different
Motor Supply GND must be externally connected to earth
Caution:
By exceeding 53VDC Power Supply Signal, the controller will go into error state, voltage higher than 55
VDC will damage the controller!
By exceeding 76 VDC Motor Supply Signal, the controller will go into error state, voltage higher than 79
VDC will damage the controller!
Do not switch Power Supply DC Voltage. All power supply switching and E-Stop breaks should be done
to the AC supply voltage of the power supplies
Power supply connectors must not be connected or disconnected while DC voltage is present.
LED
State Display
Fault
Ready
Stat A
Stat B
Ready Green
Stat A Yellow
Stat B Yelllow
Fault red
READY The system has started correctly
STAT A Coding for the actual operating state
STAT B Coding for the actual operating state
The display of the various operating states is shown on the last page of this manual.
FAULT An error has occurred
(In the state ERROR a blink code of the STAT LEDs A and B tells what the actual
error is. The blink codes are explained in chapter ‘Service’of the user Manual.)