Description of the connectors / Interfaces 

 
 
 

 

Power Supply 

Power Connector Motor 

1 GND

2  +

 

 

Power Connector Signal 

1 PWR
2 GND

 

Power Connector
Motor

GND

   48...72VDC

GND internally 

connected to

controller housing

Internal 
Fuse 10AT

Supply GND

must be externally

connected to earth

GND

1

2

PWR Motor +

48...72VDC

Power Connector
Signal

GND

24...48VDC

GND internally 

connected to

controller housing

Supply GND

must be externally

connected to earth

1

GND

3

   24...48VDC

Internal 
Fuse 500mAT

PWR

2 3

1

 

 

 
 
 

 

Power Supply Motor:      

Wiring:  2.5 mm² (AWG12), max length 5 m 
Supply Voltage 48...72 VDC. Absolute max. Rating 72VDC + 5% 
Supply voltage for PWR Signal and PWR Motor may be different  
Motor Supply GND must be externally connected to earth 
 

Power Supply Signal:       

Wiring:  1.5 mm² (AWG16), max length 5 m 
Supply Voltage 24...48VDC. Absolute max. Rating 48VDC + 10% 
Supply voltage for PWR Signal and PWR Motor may be different  
Motor Supply GND must be externally connected to earth 
 

Caution:

 

By exceeding 53VDC Power Supply Signal, the controller will go into error state, voltage higher than 55 
VDC will damage the controller! 
By exceeding 76 VDC Motor Supply Signal, the controller will go into error state, voltage higher than 79 
VDC will damage the controller! 
Do not switch Power Supply DC Voltage. All power supply switching and E-Stop breaks should be done 
to the AC supply voltage of the power supplies 
Power supply connectors must not be connected or disconnected while DC voltage is present. 
 

LED 

State Display 

 

Fault

         Ready

Stat A

         Stat B

 

 
Ready  Green 
 
 
Stat A Yellow 
Stat B Yelllow 
 
 
 
Fault   red 
 

 
READY     The system has started correctly 
 
 
STAT A     Coding for the actual operating state 
STAT B     Coding for the actual operating state 
The display of the various operating states is shown on the last page of this manual. 
 
FAULT     An error has occurred  
(In the state ERROR a blink code of the STAT LEDs A and B tells what the actual 
error is. The blink codes are explained in chapter ‘Service’of the user Manual.) 
 
 
 
 

Содержание LinMot E1030 Series

Страница 1: ...30 DP E2030 DP E4030 DP Content IMPORTANT NOTES FOR E1030 E2030 E4030 SERIES CONTROLLERS 2 SYSTEM OVERVIEW 3 E1030 SERIES FUNCTION AND WIRING 4 POWER SUPPLY AND GROUNDING 5 DESCRIPTION OF THE CONNECTO...

Страница 2: ...llers Do not switch Power Supply DC Voltage All power supply switching and E Stop breaks should be done to the AC supply voltage of the power supply Do not connect or disconnect the motors from contro...

Страница 3: ...Motor 48 72 V From AC Mains 1x115V AC 1x230V AC RS232 Interface to PC for Configuration Linear Motor with internal Position Feedback Power Supply Signal 24 48 V Profibus DP address Profibus DP Interfa...

Страница 4: ...30 4030 NTI AG Installation E1030 E2030 E4030 series 16 09 2005 Page 4 12 E1030 series Function and Wiring Picture shows typical wiring of a single axes controller Multiple axes controller will have a...

Страница 5: ...n order to assure a safe and error free operation and to avoid severe damage to system components all system components must be well grounded to either a single earth or utility ground This includes b...

Страница 6: ...Supply voltage for PWR Signal and PWR Motor may be different Motor Supply GND must be externally connected to earth Caution By exceeding 53VDC Power Supply Signal the controller will go into error st...

Страница 7: ...tor wiring may damage Linear Motors and or Servo Controller If you are assembling motor cables by your own double check motor wiring carefully before power up Do not connect or disconnect the motors f...

Страница 8: ...0 2030 4030 NTI AG Installation E1030 E2030 E4030 series 16 09 2005 Page 8 12 DP Profibus Connector DSUB 9 female Isolated 5V output max 50 mA Profibus ID ID High ID Low ID 1 Profibus address high ID...

Страница 9: ...es 16 09 2005 Page 9 12 Mechanical Dimension Dimensions 295 64 90 330 179 Centers 315 Fixings for 2 x M5 screws Recommended mounting for multiple controller installation Fixings for 2 x M5 screws LinM...

Страница 10: ...pplications Controller Voltage Power LinMot Switched Power Supply Part Nr E1000 1 motor 72 V 300 W S01 72 300 0150 1942 E2000 Up to 2 motors 72 V 600 W S01 72 600 0150 1943 E4000 Up to 4 motors 72 V 6...

Страница 11: ...within the User s Manual a copy of which may be obtained from NTI Ltd I declare that as the authorized representative the above information in relation to the supply manufacture of this product is in...

Страница 12: ...supply voltage for the Power circuitry is too low 3x l l l l The supply voltage for the Power circuitry is too high 4x l l l l The supply voltage for the Signal circuitry is too low 5x l l l l The sup...

Отзывы: