Chapter 1 - Getting Started
RAID Controllers
13
Dust covers are provided to protect the transceivers’ optics. It is highly
recommend that the dust covers be installed when a connector is not in place.
Installing and Removing SFP Dust Covers
RAID Controllers
The NexStor 4200F Series Storage System is designed to house one or two hot
pluggable embedded end-to-end 2 GB/sec Fibre Channel RAID Controllers. Theses
RAID Controllers are second generation FFx2 model high-performance mid-range
RAID controllers supporting full RAID level 0, 1, 0+1, 3, 5, 10, 30, and 50
capabilities.
The RAID Controllers are designed for “I/O Intensive” and “Bandwidth Intensive”
applications, which provide configurations for simplex and duplex (dual-active)
operations in existing and future Fibre Channel topologies. In simplex operations,
the controller operates autonomously. In dual-active configurations, the two
controllers operate as a pair. In the event one controller fails, fault tolerance is
maintained via fail-over/fail-back allowing either controller to take over the
operations of the other controller. In a dual-active configuration, each controller
determines the existence and status of the other, through communication over the
backend Device FC Loop.
SES
CO
NTR
OLLE
R
PART
NU
MBER
08-
9-96
3220
01
ARTW
ORK
RE
VISIO
N -1
JP1
JP2
RS-23
2
A
D
0
A
D
1
A
D
2
S
P
1
S
P
2
B
D
R
D
L
Y
R
M
T
SES
D1
DISK I/O
D2
Tx
Tx
Tx
Fibre Disk IO LRC
P/N 08-9-96318001
A/W Re
v-1
INST
ALL JUMPERS 1 & 2
FOR HARD
WARE
FAILURE DETECT
ADD JUMPER FOR
1G OPERA
TION
JP2
JP2
JP3
JP1
ADD JUMPER FOR
SPLIT B
US MODE
D1
DIS
K I/O
D2
Tx
Tx
Tx
Fibre Disk IO L
RC
P/N 08-9-96318
001
A/W Re
v-1
INST
ALL JUMPERS 1
& 2
FOR HARD
WARE
FAILURE DETECT
ADD JUMPER FO
R
1G OPERA
TION
JP2
JP2
JP3
JP1
ADD JUMPER FO
R
SPLIT B
US MODE
10/100TX
BBU
FAULT
PRTNR
FAIL
PWR
RDY
DRV
1
HOST
1
DRV
0
HOST
0
CACHE
DIR
TY NOT
RDY
RS-232
10/100TX
BBU
FAULT
PRTNR
FAIL
PWR
RDY
DRV
1
HOST
1
DRV
0
HOST
0
CACHE
DIR
TY NOT
RDY
RS-232
H
OS
T
I/O
OK
OK
2G
SWIT
CH C
ONN
ECTI
OON
S
PIN 1
- 1G
/2G
PIN 2
W
AHO
O
PIN 3
- H
UB F
AILO
VER
PIN 4
- C
0C1_
ENB
PIN 5
- C
0CH
0CH
1_EN
B
PIN 6
- V
CC
PIN 7
- V
CC
PIN 8
- V
CC
FIBR
E HO
ST IO
P/N 0
8-9-9
6319
001
A/W R
EV-1
H
OST
I/O
OK
OK
2G
SWITCH CONNEC
TIOONS
PIN 1 - 1G/2G
PIN 2
WAHOO
PIN 3 - HUB F
AILO
VER
PIN 4 - C0C1_ENB
PIN 5 - C0CH0CH
1_ENB
PIN 6 -
VCC
PIN 7 -
VCC
PIN 8 -
VCC
FIBR
E H
OST IO
P/N 08-9-96319001
A/W
REV
-1
H1
H0
H0
H1
Install the Dust Covers
when the optical transceiver
port is not in use.
4200F.book Page 13 Thursday, January 23, 2003 2:47 PM
Содержание NexStor 4200F Series
Страница 2: ...4200F book Page 2 Thursday January 23 2003 2 47 PM...
Страница 8: ...Table of Contents iv 4200F book Page iv Thursday January 23 2003 2 47 PM...
Страница 12: ...About this Manual Features viii 4200F book Page viii Thursday January 23 2003 2 47 PM...
Страница 32: ...Chapter 1 Getting Started Audible Alarm 20 4200F book Page 20 Thursday January 23 2003 2 47 PM...
Страница 156: ...Chapter 6 Maintenance Replacing the Enclosure 144 4200F book Page 144 Thursday January 23 2003 2 47 PM...
Страница 160: ...Appendix A Technical Information Specifications 148 4200F book Page 148 Thursday January 23 2003 2 47 PM...
Страница 172: ...Index 160 4200F book Page 160 Thursday January 23 2003 2 47 PM...
Страница 173: ...4200F book Page 161 Thursday January 23 2003 2 47 PM...