SET-UP:

Fill the holding tank with clear water and the detergent of your choice. Mix well. Although this
machine is designed to supply instant hot water, the addition of warm or hot water to the holding tank
would be a plus factor.

1. Plug in cord #1 (vac and pump), identified by the 4" long red band on the end of the cord. Attach

the priming hose to the machine. Turn the pump on and set the switch to the upholstery setting.
Run until the pump is fully primed, then turn off the pump. Remove the priming hose and attach
the cleaning hoses and tool.

2. Turn on the pump and spray through the cleaning tool for a few seconds to fill the lines with

solution.

3. Plug in cord #2. IF THE GREEN LIGHT ILLUMINATES, THE HEAT EXCHANGER WILL TURN

ON AUTOMATICALLY (SEE NOTE BELOW). Wait 2 minutes for the heat exchanger to reach
operating temperature. You may now begin cleaning. It will take about 10 seconds for the initial
heat to reach the wand.

NOTE: 240 Volt machines do not have a green light.

NOTE: If the green circuit indicator light does not illuminate when cord #2 is plugged in, then
both cords are on the same line. Try other outlets until the light comes on. See the bypass
switch section (below) if you are unable to get a green light.

BYPASS SWITCH:

NOTE: 240 Volt machines do not have a Bypass Switch.

The bypass switch completely bypasses the circuit locator. Use this feature when you cannot get
the green light to come on and you believe that the two cords are on separate circuits.

CAUTION: If the bypass switch is on and the two cords are plugged into the same circuit, the
breaker will blow.

ELECTRIC CIRCUIT LOCATOR:

NOTE: 240 Volt machines do not have an Electronic Circuit locator.

This unique, patented “smart system”, operated by a solid state circuit, will inform the operator when
the two cords are plugged into separate lines by illuminating the green indicator light. This helps
prevent tripping circuit breakers.

BALL FLOAT VAC SHUTOFF:

When the recovery tank is full, the float system will shut off the incoming air flow and prevent water
from entering the vacuum motor. The float may not work properly if the float filter is clogged or if
there is heavy foam in the tank.

CAUTION: To avoid vac motor damage, always make sure the float filter is clean and the ball
travels freely before turning on the machine. Use a defoamer whenever foam is present.

SAFETY PRECAUTIONS:

All extension cords must have a rating of at least 12/3 (#12 cord). Extension cords should be no
longer than 50 feet. Replace the plug immediately if the ground prong becomes damaged or is
broken off. Not only is the ground necessary for safety, but the circuit locator system will not
operate correctly without it.

https://harrissupplyind.com - To Order Parts Call 608-268-8080

Содержание PREDATOR CX300HP

Страница 1: ...rom the electrical outlet NEVER operate this machine in the presence of flammable or combustible liquids or fumes When any electrical motor switch cord or plug service is required maintenance should o...

Страница 2: ...wders may be used but unless mixed very thoroughly they could cause build up in the lines pump quick disconnects etc A pH of 7 9 is strongly recommended to avoid premature pump wear which would void t...

Страница 3: ...h The bypass switch completely bypasses the circuit locator Use this feature when you cannot get the green light to come on and you believe that the two cords are on separate circuits CAUTION If the b...

Страница 4: ...age for explanation of the bypass system GREEN CIRCUIT LOCATOR LIGHT 5 When this light is illuminated it confirms that the machine is on two separate circuits See previous page for additional informat...

Страница 5: ...detergent White vinegar Berry stain Liquid detergent Ammonia 3 6 Water Bleach Liquid detergent Water Blood dried Warm detergent Ammonia 3 6 Water Blood wet Liquid detergent Water Butter Volatile solve...

Страница 6: ...Circuit Board N A on 240V 57 4091321 Snap Track N A on 240V 58 4091361 Wheel 8 59 4091021 Axle Cap 60 4090071 Label NSS 61 9120900 1 4 Hex Nut w Ny Lok 62 4091141 Axle Bracket 63 4090611 1 4 20 X 3 4...

Страница 7: ...66 65 54 53 91 91 91 22 23 89 92 29 88 85 87 86 85 84 95 90 103 90 91 89 29 96 98 97 97 86 99 100 101 97 86 102 11 10 12 13 14 16 15 35 51 53 27 26 25 93 20 21 22 47 48 50 49 80 82 79 78 81 83 94 26A...

Страница 8: ...TE RED TEMP CONTROL HEATER TC CIRCUIT BOARD BYPASS SWITCH WHITE BLACK DUAL CORD SENSOR WHITE WHITE BLACK GREEN LIGHT BLACK WHITE P1 P7 P6 P5 P2 P3 P4 CORD 2 GROUND VACUUM BLACK SW BLACK BLUE RED FAN W...