![NSR Marine NGR-1000 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/nsr-marine/ngr-1000/ngr-1000_user-manual_1714730050.webp)
NGR-1000/NGR-3000 USER MANUAL
NGR-1000/NGR-3000 UM.E 20190331-04
44
ALF - Alert sentence
$--ALF, x, x,x,hhmmss.ss,a,a,a,aaa,x.x,x.x,x.x,x,c---c*hh <CR><LF>
| | | | | | | | | | | | |
| | | | | | | | | | | | +------------------------ 13
| | | | | | | | | | | +------------------------ 12
| | | | | | | | | | +------------------------- 11
| | | | | | | | | +------------------------- 10
| | | | | | | | +-------------------------- 9
| | | | | | | +---------------------------- 8
| | | | | | +--------------------------- 7
| | | | | +----------------------- 6
| | | | +-------------------- 5
| | | +---------------------------- 4
| | +-------------------------- 3
| +----------------------- 2
+---------------------1
1. Total number of ALF sentences for this message, 1 to 2 (see Note 1)
2. Sentence number, 1 to 2 (see Note 1)
3. Sequential message identifier, 0 to 9 (see Note 2)
4. Time of last change (see Note 3)
5. Alert category, A, B or C (see Note 4)
6. Alert priority, E, A, W or C (see Note 5)
7. Alert state, A, S, R, O, U or D (see Note 6)
8. Manufacturer mnemonic code (see Note 7)
9. Alert identifier (see Note 8)
10. Alert instance, 1 to 999999 (see Note 9)
11. Revision counter, 1 to 99 (see Note 10)
12. Escalation counter, 0 to 9 (see Note 11)
13. Alert text (see Note 12)
NOTE 1:
The first field specifies the total number of sentences used for a message, minimum
value 1. The second field identifies the order of this sentence in the message,
minimum value 1, These cannot be null fields. When the sentence number is 2, the
following Alert category, Alert priority and Alert state can be null fields.
NOTE 2:
The sequential message identifier relates all sentences that belong to a group of
multiple sentences (i.e. message). Multiple sentences (see Note 1) with the same
sequential message identifier, make up one message.
NOTE 3:
Time should represent the last time the data within the alert message has changed.
For example changing the alert text by in-/decrementing a contained counter or
count down should cause a revision of alert message and a new time. Time is an
optional field. The time-field is additional information about when this happened
and not used for decision making. There is no mandatory requirement for time
synchronization between the equipment. It should by either a null field (if not used)
or UTC (if used). Sender is allowed to use all alternatives defined in Table 5 Field
type summary. Receiver is allowed to ignore content of this field. If the receiver
Содержание NGR-1000
Страница 1: ...USER MANUAL GNSS equipment NGR 1000 NGR 3000 NGR 1000 NGR 3000 UM E 20190331 04...
Страница 43: ...NGR 1000 NGR 3000 USER MANUAL NGR 1000 NGR 3000 UM E 20190331 04 37 APPENDIX I MENU TREE...
Страница 44: ...NGR 1000 NGR 3000 USER MANUAL NGR 1000 NGR 3000 UM E 20190331 04 38...
Страница 47: ...NGR 1000 NGR 3000 USER MANUAL NGR 1000 NGR 3000 UM E 20190331 04 41 APPENDIX III SENTENCE DISCRIPTION...
Страница 63: ...NGR 1000 NGR 3000 USER MANUAL NGR 1000 NGR 3000 UM E 20190331 04 57 APPENDIX IV INSTALLATION DRAWINGS...
Страница 64: ......
Страница 65: ......
Страница 66: ......
Страница 67: ......
Страница 68: ......
Страница 69: ......
Страница 70: ...NGR 1000 NGR 3000 USER MANUAL NGR 1000 NGR 3000 UM E 20190331 04 64 APPENDIX V DOC...
Страница 72: ...Copyright by NEW SUNRISE CO LTD NSR www nsrmarine com info nsrmarine com March 2019...